Skip to product information
1 of 1

FU input module for logger MS

FU input module for logger MS

SKU: SKU: M1047 Download PDF

Sold out
Shipping Available
Free shipping on orders above $1000.* Only on standard purchases of cables and wires.
View full details
Product Information

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Resources

Description:

Input module designed for measuring frequency of a voltage signal ranging from 0 to 5 kHz with a resolution of 1 Hz and an accuracy of ±(02% from reading + 1 Hz) It accommodates an input voltage for state "H" between 3 to 24 Vdc and has an input current in state "H" of approximately 7 mA The minimum duration of the input impulse is 30 microseconds and is galvanically isolated.

Features and Benefits:

    •Measures frequency of voltage signal from 0 to 5 kHz.

    •Resolution of 1 Hz.

    •Accuracy of ±(0.2% from reading + 1 Hz).

    •Input voltage for state "H": 3 to 24 Vdc.

    •Input current in state "H": approximately 7 mA.

    •Minimum duration of input impulse: 30 microseconds.

    •Galvanically isolated.

Specifications:

 Input Frequency Range: 0 to 5 kHz
 Resolution: 1 Hz
 Accuracy: ±(0.2% from reading + 1 Hz)
 Input Voltage (state "H"): 3 to 24 Vdc
 Input Current (state "H"): approximately 7 mA
 Minimum Duration of Input Impulse: 30 microseconds
 Isolation: Galvanically isolated

 