{"product_id":"vntc-unshielded-10-19-thwn-or-thhn","title":"VNTC Unshielded 10\/19 THWN or THHN","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003cp\u003eVNTC Unshielded 10 AWG\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis multi-conductor cable employs Class B, fully annealed stranded tinned copper conductors.  The copper conductors align with ASTM standards B33 and B8.  The annealed copper product used in this cable offers superior flexibility compared to standard copper conductors.  The annealed metal undergoes a process in which the copper is heated and then slowly cooled, removing internal stress to make the copper more malleable.   The VNTC Unshielded Tray cable is available with Type THHN or THWN conductors.  THHN conductors are high heat-resistant, while THWN offers heat resistance and water resistance as well.  The copper conductors are insulated in polyvinyl chloride (PVC) insulation that bears a clear polyamide (nylon) coat.  An exterior PVC jacket encases the conductors and protects them from abrasion and corrosion due to flame, moisture, oil, sunlight, ozone, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable’s construction allows it to be used in wet or dry locations in temperatures up to 90°C when dry, 75°C when wet.  The cable has a cold bend rating of -20°C and meets crush and impact requirements of Type MC cable.  The cable passes UL, IEEE, and CSA flame tests and is therefore deemed suitable for use in hazardous locations.   The cable offers great resistance to oil, so it is often used in motor leads or oil drilling applications.  The VNTC Unshielded cable can be used in direct burial applications, free air, or installed in raceways or conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable adheres to UL standard 66 which states construction, testing, and marking requirements for fixture cables.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe cable also aligns with UL standard 1277 for Type TC-ER cables with three or more conductors.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe cable meets or exceeds UL 1581 requirements for jacketed conductors.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThe VNTC Unshielded 10 AWG THWN or THHN is acceptable by the Occupational Safety and Health Administration.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003eThis cable passes the following flame tests: UL 1277, IEEE 383, IEEE 1202, and CSA FT-4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis multi-conductor cable employs Class B, fully annealed stranded tinned copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe copper conductors align with ASTM standards B33 and B8. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe VNTC Unshielded Tray cable is available with Type THHN or THWN conductors.\u003c\/li\u003e\n\u003cli\u003eTHHN conductors are high heat-resistant, while THWN offers heat resistance and water resistance as well. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in polyvinyl chloride (PVC) insulation that bears a clear polyamide (nylon) coat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e-\u003cspan\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAn exterior PVC jacket encases the conductors and protects them from abrasion and corrosion due to flame, moisture, oil, sunlight, ozone, and chemicals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber Of Conductors In Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced Digital Item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBelden Item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28163A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e236360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW15101019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLake Cable Item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV1019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNexans Item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e627265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOmni Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA11019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSouthwire Item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e601666\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuperior Essex Item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE2BEA-101B19CB00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAs flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 Deg. C. in dry locations, 75 Deg. C. in wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eIndividual conductors of stranded uncoated copper Type TFN (16AWG). Type THWN or THHN (14-10 AWG), color coded, two conductors flat, three or more conductors twisted, PVC jacket overall, surface printed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eListed by UL as Type TC Tray Cable per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eIndividual conductors UL listed as Type THWN or THHN (14-10 AWG) or Type TFN (16 AWG).\u003c\/li\u003e\n\u003cli\u003eOverall jacket UL listed as Sunlight Resistant.\u003c\/li\u003e\n\u003cli\u003eCables UL listed for Direct Burial.\u003c\/li\u003e\n\u003cli\u003eCables with grounding conductor UL listed for Open Wiring.\u003c\/li\u003e\n\u003cli\u003eCables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU\/hour test.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eNotes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCables designated (w\/g) contain an additional bare copper grounding conductor, same size as circuit conductors, and are UL listed for Open Wiring. Standard color coding is ICEA Method E2 or K2 for NEC applications. This color coding method omits white and green from the color sequence. ICEA Method 4 color coding is also provided. This consists of printed numbers and words, 1-ONE, 2-TWO, etc. Size 16 AWG is rated 90oC dry only.\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7688704065599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_b646ba6b-4992-43d7-8b7a-aa2a8d980ecd.jpg?v=1571729805","url":"https:\/\/nassauelectricalspot.com\/products\/vntc-unshielded-10-19-thwn-or-thhn","provider":"NassauElectrical","version":"1.0","type":"link"}