{"product_id":"s1-input-module-for-datalogger-ms","title":"S1 input module for datalogger MS","description":"[pdf]\u003cembed src=\"https:\/\/shopify-staged-uploads.storage.googleapis.com\/tmp\/1311178815\/files\/bc9cfd3f-ed9f-49e0-a34a-690a09586204\/document.pdf\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e[\/pdf]\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eS1 input module for datalogger MS Binary voltage input Voltage for \"switched ON\" state: 3 to 30Vdc, input current in the\"switched ON\" state: 1 to 9mA-depending on the applied voltage Minimum duration for indication of change: 200ms, galvanically isolated Galvanic isolation is not designed as safety protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"height: 10px; width: 90.1204%;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Voltage for \"switched ON\" state:\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e3 to 30Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Input current in the \"switched ON\" state:\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1 to 9mA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Minimum duration for indication of change:\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e200ms\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Galvanic isolation:\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eGalvanic isolation is not designed as safety protection\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"COMET","offers":[{"title":"Default Title","offer_id":41436871721023,"sku":"M1042","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/M1042_big.jpg?v=1738538698","url":"https:\/\/nassauelectricalspot.com\/products\/s1-input-module-for-datalogger-ms","provider":"NassauElectrical","version":"1.0","type":"link"}