{"product_id":"prysmian-cable-1-solid-5kv-epr-urd-100-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qj5000a","title":"Prysmian Cable 1 Solid 5kV EPR URD 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QJ5000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1 Solid 5kV EPR URD 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QJ5000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1 Solid 5kV EPR URD 100% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QJ5000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Copper Medium Voltage Utility Cable, Copper Medium Voltage Utility Price, Copper Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 133% Cable, QJ5000A, 1 Solid 5kV EPR URD 100% Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1 SOLID CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e7-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.289\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e544\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e195\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e166\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e656\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e276\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e178\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e100\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e645\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJ5000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187750649919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_37e170c8-ca19-4b2b-abed-e8a085ebc625.jpg?v=1571729312","url":"https:\/\/nassauelectricalspot.com\/products\/prysmian-cable-1-solid-5kv-epr-urd-100-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qj5000a","provider":"NassauElectrical","version":"1.0","type":"link"}