{"product_id":"prysmian-cable-1-0-solid-5kv-133-copper-single-phase-full-neutral-trxlpe-urd-medium-voltage-utility-cables-q57010a","title":"Prysmian Cable 1\/0 Solid 5kV 133% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables Q57010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 Solid 5kV 133% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables Q57010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 Solid 5kV 133% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables Q57010A. Click for a free quote. 1\/0 Solid.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Q57010A, 1\/0 Solid 5kV 133% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables Q57010A, Q57010A, 5kV TRXLPE URD Cable, TRXLPE URD Cable, Medium Voltage Utility Cables, TRXLPE Insulation Cable, LLDPE Jacket Cable, Aluminum Single Conductor Cable, Copper  Single Conductor Cable, URD Cable, 5kV TRXLPE URD 133% Copper Medium Voltage Utility Cables\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength VOLTENE™ TRXLPE insulation, exhibiting an optimum balance of mechanical and electrical properties, insuring resistance to treeing.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE™ TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e\n        • Black LLDPE jacket with no stripes\u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape\u003cbr\u003e\n        • No Jacket\u003cbr\u003e\n        • Multiplex cables\u003cbr\u003e\n        • Tinned round and flat strap neutrals\u003cbr\u003e\n        • Compact stranded conductors\u003cbr\u003e\n        • Strandseal®\u003cbr\u003e\n        • Super smooth conductor shield\u003cbr\u003e\n        • UL MV-90 Rating if required\u003cbr\u003e\n        • 46kV\u003cbr\u003e\n        • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e\n        • Conduit in Air\u003cbr\u003e\n        • Direct Buried\u003cbr\u003e\n        • Underground Duct\u003cbr\u003e\n        • Isolated in Air\u003cbr\u003e\n        • Wet Locations\u003cbr\u003e\n        • Dry Locations\u003cbr\u003e\n        • With Messenger\u003cbr\u003e\n        • Utility Primary\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e\n        • AEIC- AEIC CS8\u003cbr\u003e\n        • ICEA- ICEA S-94-649\u003cbr\u003e\n        • For 90°C continuous, 130°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 Solid cu\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e115\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.325\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.94\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e871\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e198\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e256\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e256\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 90°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e277\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e256\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e256\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQ57010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187805503551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20TRXLPE_20URD-lg_48debeef-3629-48d1-aeb3-5ba4f0ea6003.jpg?v=1571729336","url":"https:\/\/nassauelectricalspot.com\/products\/prysmian-cable-1-0-solid-5kv-133-copper-single-phase-full-neutral-trxlpe-urd-medium-voltage-utility-cables-q57010a","provider":"NassauElectrical","version":"1.0","type":"link"}