{"product_id":"pce-as1-portable-100-lpm-air-sampler-for-bacterial-and-fungal-analysis","title":"PCE-AS1 - Portable 100 lpm Air Sampler for Bacterial and Fungal Analysis","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eEnsure optimal air quality with the PCE-AS1 Portable Air Sampler, a reliable device designed for aerosol hygiene monitoring at a flow rate of 100 lpm This advanced instrument is essential for testing airborne microorganisms, including bacteria, molds, fungi, and viruses Tailored for use in critical environments such as hospitals, clean rooms, and production areas for food, pharmaceuticals, and cosmetics, the PCE-AS1 adheres to the latest standards for airborne microbial analysis.\u003cbr\u003e\u003cbr\u003e\n\nUtilizing the aerosol impaction or Andersen collision method, this air sampler effectively collects samples by drawing air through 300 microporous openings, directing a steady stream onto an agar petri dish After completing a sampling cycle, simply incubate the petri dish to evaluate bacterial and fungal presence per USP 797 and CAG-009 guidelines\n\nFor added convenience, the collecting head can be sterilized in an autoclave at 121° C for 30 minutes, or alternatively cleaned with a cloth soaked in 75% alcohol.\u003cbr\u003e\u003cbr\u003e The agar petri dish can also be disinfected with the same solution, ensuring thorough sanitation for accurate results An optional ISO calibration lab certificate is available for those seeking added assurance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e•Backlit LCD.\u003c\/p\u003e\n\u003cp\u003e•Memory for up to 99 parameters.\u003c\/p\u003e\n\u003cp\u003e•Sterilizable collecting head.\u003c\/p\u003e\n\u003cp\u003e•Adjustable volumes of up to 6000 l.\u003c\/p\u003e\n\u003cp\u003e•Powerful battery.\u003c\/p\u003e\n\u003cp\u003e•Use of standard petri dishes.\u003c\/p\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\" style=\"height: 10px; width: 90.1204%;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Number of micropores in the collecting head\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e589\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Hole diameter of the micropores\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e0.8 mm \/ 0.03\"\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Battery\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e6400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Sample throughput\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e100 liters per minute (l\/min) or 3.53 cubic feet per minute\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Flow rate at measuring head\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e0.38 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Automatic control of the measuring volume\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e10 ... 6000 liters\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Dimension of plate\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eø 70 ... 90 x 15 mm \/ ø 2.76 x 3.54 x 0.59 inches\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Data storage max.\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e99 parameters and 2000 measurement values\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Dimensions\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eø 120 x 300 mm \/ ø 4.72 x 11.81 inches\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Standards\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eISO 14698-1\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/document_78798fa8-a094-4627-b7a4-b16bf1c3f3ce.pdf?v=1745951544\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":41663796543551,"sku":"PCE-AS1","price":4335.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/download_060ddbdb-42be-49db-86c3-4e18608c3768.webp?v=1745951624","url":"https:\/\/nassauelectricalspot.com\/products\/pce-as1-portable-100-lpm-air-sampler-for-bacterial-and-fungal-analysis","provider":"NassauElectrical","version":"1.0","type":"link"}