{"product_id":"pce-830-1-advanced-3-phase-clamp-meter-with-backlit-lcd-and-data-logging","title":"PCE-830-1 - Advanced 3-Phase Clamp Meter with Backlit LCD and Data Logging","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIntroducing the PCE-830 Clamp Meter, a versatile tool engineered for measuring electrical quantities in one to three-phase alternating current (AC) systems This advanced 3-Phase Clamp Meter not only tracks critical parameters such as voltage, current, frequency, and power but also provides insights into harmonic values, interharmonics, and asymmetries, all compliant with the EN50160 standard\n\nDetect electrical interference like interruptions, overloads, and transients (starting from 16 µs), and view up to 35 parameters at once on a high-resolution backlit LCD.\u003cbr\u003e\u003cbr\u003e The device can accommodate up to three clips simultaneously for enhanced measurement capabilities\n\nIn data logger mode, the PCE-830 can store an impressive 17,470 readings when measuring three phases with four conductors For simpler setups involving one phase and two conductors, it can retain up to 52,400 readings organized into 85 distinct groups This makes the PCE-830 an essential instrument for long-term measurements.\u003cbr\u003e\u003cbr\u003e\n\nConveniently, the gathered data can be transferred to a computer for further analysis using the included software The meter arrives fully equipped for immediate use, calibrated from the factory For those who require it, optional laboratory calibration and ISO-certified documentation can be requested at the time of purchase or for future recalibrations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e•Analysis of a network of 3 phases \/ 4 conductors, 3 phases \/ 3 conductors, 1 phase \/ 2 conductors, 1 phase \/ 3 conductors.\u003c\/p\u003e\n\u003cp\u003e•Measures effective real value (V123 and I123).\u003c\/p\u003e\n\u003cp\u003e•Measures active power (W, KW, MW, GW).\u003c\/p\u003e\n\u003cp\u003e•Measures apparent and reactive power (KVA, KVAR).\u003c\/p\u003e\n\u003cp\u003e•Power Factor (PF), phase angle (Φ).\u003c\/p\u003e\n\u003cp\u003e•Measures energy and work (Wh, KWh, KVARh, PFh).\u003c\/p\u003e\n\u003cp\u003e•Measures current from 0.1 mA to 3000 A, allowing for the reserve power of a factory to be determined.\u003c\/p\u003e\n\u003cp\u003e•Large LCD that shows up to 35 parameters simultaneously (3P4W [=3 phases\/4 conductors]).\u003c\/p\u003e\n\u003cp\u003e•CT conditions (1 to 600) and PT (1 to 3000) are programmable.\u003c\/p\u003e\n\u003cp\u003e•Indicates current wave forms and voltage overlap.\u003c\/p\u003e\n\u003cp\u003e•512 KB of memory with programmable intervals to save data every 2 to 3000 seconds, 17,470 readings using the system of 3 phases \/ 4 conductors.\u003c\/p\u003e\n\u003cp\u003e•Indicates wave forms, efficiency parameters, and harmonic distortion.\u003c\/p\u003e\n\u003cp\u003e•Backlit LCD with dot matrix.\u003c\/p\u003e\n\u003cp\u003e•Average power (AD in W, KW, MW).\u003c\/p\u003e\n\u003cp\u003e•Maximum power (MD in W, KW, MW) with the programmable period.\u003c\/p\u003e\n\u003cp\u003e•Analysis of harmonic distortion up to a curvature of 99.\u003c\/p\u003e\n\u003cp\u003e•Indication of up to 50º form of harmonic wave.\u003c\/p\u003e\n\u003cp\u003e•Indication of the wave form with maximum value (1024 readings \/ period).\u003c\/p\u003e\n\u003cp\u003e•Analysis of absolute distortion (%THD-F).\u003c\/p\u003e\n\u003cp\u003e•Diagram of graphic equilibrium with parameters of a 3 phase system.\u003c\/p\u003e\n\u003cp\u003e•Detects up to 28 transistors (time and cycles) with a programmable threshold (%).\u003c\/p\u003e\n\u003cp\u003e•Relation of 3 phases of voltage or asymmetrical current (VUR).\u003c\/p\u003e\n\u003cp\u003e•Factor of 3 phases of voltage and asymmetrical current (d0%, d2%).\u003c\/p\u003e\n\u003cp\u003e•USB port (optically insulated).\u003c\/p\u003e\n\u003cp\u003e•Integrated timer and calendar to record data.\u003c\/p\u003e\n\u003cp\u003e•Maximum diameter of the electrical conductor for the amp clamp: the PCE-6801 ~30 mm \/ 1.2 in, PCE-6802 ~55 mm \/ 2.2 in, PCE-3007 ~170 mm \/ 6.7 in.\u003c\/p\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\" style=\"height: 10px; width: 90.1204%;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e5.0 W to 999.9 W \/ 0.1 W \/ ±1% ±0.8 W; 1.000 kW to 9.999 kW \/ 0.001 kW \/ ±1% ±8 W; 10.00 kW to 99.99 kW \/ 0.01 kW \/ ±1% ±80 W; 100.0 kW to 999.9 kW \/ 0.1 kW \/ ±1% ±0.8 kW; 1000 kW to 9999 kW \/ 1 kW \/ ±1% ±8 kW\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Current AC (50 Hz or 60 Hz, auto range select, TRMS)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e0.04 A to 1 A \/ 0.001 A \/ ±0.5% ±0.05 A; 0.4 A to 10.0 A \/ 0.01 A \/ ±0.5% ±0.05 A; 4 A to 100.0 A \/ 0.1 A \/ ±1.0% ±0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Voltage AC (50 Hz or 60 Hz, TRMS)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e20.0 V to 500.0 V \/ 0.1 V \/ ±0.5% ±5 digits; 20.0 V to 600.0 V \/ 0.1 V \/ ±0.5% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Harmonic distortion of AC voltage\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1º to 20º \/ 0.1% \/ ±1.0%; 21º to 49º \/ 0.1% \/ 4% of reading ±2.0%; 50º to 99º \/ 0.1% \/ 6% of reading ±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Harmonics of AC current in %\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1º to 20º \/ 0.1% \/ ±0.2% of reading ±1.0%; 11º to 20º \/ 0.1% \/ ±2% of reading ±1.0%; 21º to 50º (A)\/ 0.1% \/ ±5% of reading ±1.0%; 21º to 50º (mA)\/ 0.1% \/ ±10% of reading ±1.0%; 51º to 99º \/ 0.1% \/ ±35% of reading ±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Power Factor (PF)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e0.00 to 1.00 \/ 0.01 \/ ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Phase angle (Phi)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e-180° to 180° \/ 0.1° \/ ±1°\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Total harmonic distortion\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e0.0 to 20.0% \/ 0.1% \/ ±1%; 20.0% to 100% \/ 0.1% \/ ±3% of reading ±5%; 100% to 999.9% \/ 0.1% \/ ±10% of reading ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Maximum measurement of AC voltage and current\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e50 Hz \/ 19 µS \/ ±5% ±30 digits; 60 Hz \/ 16 µS \/ ±5% ±30 digits\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Peak value measurement of AC voltage and current\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1.00 to 99.99 \/ 0.01 \/ ±5% ±30 digits\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Frequency range in automatic mode\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e45 Hz to 65 Hz \/ 0.1 Hz \/ 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Memory\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e512 kB for a maximum 52,420 readings taken by 1 phase \/ 2 conductors\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Port\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Software and cable\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eIncluded, for Windows 2000, XP, ME\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Display\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eBacklit LCD with dot matrix\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Power\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e8 AA batteries (Mignon)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Dimensions\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e257 mm x 155 mm x 57 mm; 10.1 in x 6.1 in x 2.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Operating conditions\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eMax. 85% relative humidity \/ -10 ... 50ºC \/ 14 ... 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Type of protection \/ standards\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eIEC 61010, 600 V\/CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/document_751dc2eb-0cc9-49ca-809a-81495d82d80a.pdf?v=1745949487\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":41663767511103,"sku":"PCE-830-1","price":3155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/download_a752590e-a8dc-4905-9b82-b8a6bab12c59.webp?v=1745949538","url":"https:\/\/nassauelectricalspot.com\/products\/pce-830-1-advanced-3-phase-clamp-meter-with-backlit-lcd-and-data-logging","provider":"NassauElectrical","version":"1.0","type":"link"}