{"product_id":"hunter-jacketed-decoder-cables-direct-burial-12-awg-tan","title":"HUNTER JACKETED DECODER CABLES DIRECT BURIAL - 12 AWG Tan","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e170802TN\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003emm2\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e3, 32\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eTan\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eShipping Weight Lbs\/1000'\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e80\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eShipping Weight Kg\/328m\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e36\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eHUNTER JACKETED\u003c\/li\u003e\r\n            \u003cli\u003eDECODER CABLES\u003c\/li\u003e\r\n            \u003cli\u003eDIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14 \u0026amp; 12 AWG, SOLID COPPER, 2-CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers jacketed cables containing two listed Sprinkler Systems Wires, single conductor, suitable for direct burial, for operation up to 600 volts, and temperatures up to 60ºC.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInner Conductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft drawn bare copper meeting the requirements of ASTM specification B-3 or B-8. Insulation shall be low density high molecular weight polyethylene and a thickness of 0.045\", per Paige Electric specification P7079D. The two conductors (blue and red) shall be twisted with a minimum lay of 4\".\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        High density polyethylene with a thickness of 0.035\". Available with different color jackets. The jacket shall be sufficiently round, and loose, to facilitate its removal when being stripped. Minimum inner diameters of the outer jacket:\u003cbr\u003e\r\n        14 AWG\/2c - 0.358\"\/9.1mm\u003cbr\u003e\r\n        12 AWG\/2c - 0.386\"\/9.8mm\u003c\/p\u003e\r\n        \u003cp\u003eA \"T\" drill bit, whose diameter is 0.358\", shall be used to measure the minimum inner diameter of 14 AWG\/2c cables. A \"W\" drill bit, whose diameter is 0.386\", shall be used to measure the minimum inner diameter of 12 AWG\/2c cables.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print Inner Conductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        “Paige Electric P7079D 14 AWG PE Listing file Number 600V Sprinkler System Direct Burial”\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print Outer Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        “Paige Electric, P7354D, 14 or 12 AWG PE 600V Sprinkler System Wire Direct Burial Only for Hunter Decoder Systems RoHS”\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eTemperature Rating Color Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        -55ºC to +60ºC\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        1000' (328m), 2500' (762m) and some odd lengths.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D).\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7150347616319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HUNTER-lg_8dc78b7c-386e-43ae-b8db-62cfd3a46eaa.jpg?v=1571727074","url":"https:\/\/nassauelectricalspot.com\/products\/hunter-jacketed-decoder-cables-direct-burial-12-awg-tan","provider":"NassauElectrical","version":"1.0","type":"link"}