{"product_id":"hf23-indoor-outdoor-central-tube-single-jacket-plenum-cable-type-ofnp-csa-ft-6-4-fiber-count","title":"HF23 INDOOR\/OUTDOOR CENTRAL TUBE SINGLE JACKET PLENUM CABLE Type OFNP, CSA FT-6 - 4 Fiber Count","description":"\n    \n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\n    \n    \n        \u003ctrstyle\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003eHF23 Indoor\/Outdoor Central Tube Single Jacket Plenum Cable Type OFNP, CSA FT-6\u003c\/p\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eThis nonconductive optical fiber plenum cable comes with the option of 2-12 fibers with a dry central tube.  The central tube includes an absorbent polymer that soaks up any interior moisture.  The cable is designed for flexibility and is incredibly easy to install.  The dry loose tube construction of the cable also makes for easy termination when necessary.  Aramid fiber yarn serves as the overall strength member of the cable.  The assembly is jacketed in a black UV and moisture-resistant coating that composed of flame retardant materials.  Sequential markings on the exterior jacket measure footage for reference during installation.\u003c\/p\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eThis cable is used as a backbone for voice and communication data within a building.  The plenum cable is intended for runs between floors or between buildings.  The cable can be installed in ducts or conduits, or can be aerially lashed.  When installed in compliance with NEC article 770-51(a) and 770-53(a).  Type OFNP can also be installed in plenum airways and horizontal applications.  The cable is capable of functioning at temperatures between -20°C and 70°C.  The cable has a maximum crush resistance of 150 lbs and a maximum vertical rise of 1,200 feet.  (366m).\u003c\/p\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe HF23 model cable passes the CSA FT-6 flame test.  This test requires the product to be able to retard flames up to 70,000 BTU.\u003c\/li\u003e\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe product is Listed Type OFNR in accordance with specifications set forth by ETL and c(ETL).\u003c\/li\u003e\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eInsulated Cable Engineers Association (ICEA) standard S-104-696 approves this cable for use in outdoor plants.\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eFibers\u003c\/span\u003e\u003c\/p\u003e\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis cable comes with the option of 2-12 fibers plus a dry central tube with an absorbent polymer.  The fibers are color coded per TIA\/EIA 598B.\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eJacket\u003c\/span\u003e\u003c\/p\u003e\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe assembly is jacketed in a black flame resistant coat.  The jacket is also resistant to UV rays and moisture. \u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cbr\u003e\n        \u003cbr\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e232004XL01\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eFiber Count\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003e# Loose Tubes\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNom. Cable Diameter Inch\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNom. Cable Weight Lbs\/1000\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e34.5\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eMax Tensile Load Install Lbs\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eMax Tensile Load Long Term Lbs\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e100\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eMin Bend Radius Install Inch\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e5.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eMin Bend Radius Long Term Inch\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e2.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cbr\u003e\n        \u003c\/p\u003e\n        \u003cul\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7150325006399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/222002XL03-lg_a7eab0fc-0acd-422f-8b62-cc53bd67be38.jpg?v=1571727056","url":"https:\/\/nassauelectricalspot.com\/products\/hf23-indoor-outdoor-central-tube-single-jacket-plenum-cable-type-ofnp-csa-ft-6-4-fiber-count","provider":"NassauElectrical","version":"1.0","type":"link"}