{"product_id":"hf14-premise-tight-buffer-distribution-plenum-cable-12-fiber-count","title":"HF14 PREMISE TIGHT BUFFER DISTRIBUTION PLENUM CABLE - 12 Fiber Count","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e141012XT01\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eFiber Count\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003e# of Sub-Units\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e--\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNom. Cable Diameter Inch\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.245\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNom. Cable Weight Lbs\/1000\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e24.1\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eMax Tensile Load Install Lbs\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e320\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eMax Tensile Load Long Term Lbs\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e112\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eMin Bend Radius Install Inch\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e4.90\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eMin Bend Radius Long Term Inch\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2.45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eHF14\u003c\/li\u003e\r\n            \u003cli\u003ePREMISE TIGHT BUFFER DISTRIBUTION PLENUM CABLE\u003c\/li\u003e\r\n            \u003cli\u003eType OFNP, CSA FT-6\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eIntrabuilding voice or data communication backbones\u003c\/li\u003e\r\n            \u003cli\u003eUL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770-51(a) and 770-53(a)\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eLightweight, flexible design simplifies installation\u003c\/li\u003e\r\n            \u003cli\u003eTight buffer provides individual fiber protection\u003c\/li\u003e\r\n            \u003cli\u003eTight buffered fibers are easy to handle and strip for field connectorization\u003c\/li\u003e\r\n            \u003cli\u003eSub-units are numbered for identification\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFiber: \u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003e2-144 fibers\u003c\/li\u003e\r\n            \u003cli\u003e900µm tight buffer\u003c\/li\u003e\r\n            \u003cli\u003eColor coding per TIA\/EIA 598B\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOverall Strength Member: \u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eAramid fiber yarn\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eEpoxy\/Glass rod (above 12 fibers)\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eFlame-retardant polyvinyl chloride (PVC)\u003c\/li\u003e\r\n            \u003cli\u003eSequential footage markings\u003c\/li\u003e\r\n            \u003cli\u003eOrange jacket - multimode fibers\u003c\/li\u003e\r\n            \u003cli\u003eYellow jacket - singlemode fibers\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eTemperature:\u003c\/li\u003e\r\n            \u003cli\u003eStorage -40°C (-40°F) to +70°C (+158°F)\u003c\/li\u003e\r\n            \u003cli\u003eOperating -20°C (-4°F) to +70°C (+158°F)\u003c\/li\u003e\r\n            \u003cli\u003eMaximum Crush Resistance:\u003c\/li\u003e\r\n            \u003cli\u003e850 lbs\/in (1485N\/cm)\u003c\/li\u003e\r\n            \u003cli\u003eMaximum Vertical Rise - 1,640ft (500m)\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eUL and c(UL) Listed Type OFNP\u003c\/li\u003e\r\n            \u003cli\u003eCSA FT-6\u003c\/li\u003e\r\n            \u003cli\u003eANSI\/TIA\/EIA 568B.3\u003c\/li\u003e\r\n            \u003cli\u003eICEA S-83-596\u003c\/li\u003e\r\n            \u003cli\u003eETL Verified\u003c\/li\u003e\r\n            \u003cli\u003eGR-409\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7150318485567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/131002XT03-lg_9fb61869-c103-4928-9b1b-20878e9150a4.jpg?v=1571727054","url":"https:\/\/nassauelectricalspot.com\/products\/hf14-premise-tight-buffer-distribution-plenum-cable-12-fiber-count","provider":"NassauElectrical","version":"1.0","type":"link"}