{"product_id":"750-3-w-grnd-xhhw-tray-cable","title":"750-3 W\/GRND XHHW Tray Cable","description":"\n\n    \n        \u003ctitle\u003e750-3 W\/GRND XHHW Tray Cable\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"This cable employs three XHHW insulated copper phase conductors and one bare copper ground wire.  Each individual conductor is insulated with a cross-linked polyethylene jacket.  \"\u003e\n        \u003cmeta name=\"Keywords\" content=\"750-3 Conductor XHHW,Tray Cable, Power Cable, Copper Tray Cable, XHHW Power Cable, XHHW Power Cable- 3 Conductor, Type TC, Tray Cable wire, XHHW Power Cable- 3 Conductor With Ground\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eXHHW Power Cable-3 Conductor with Ground - Type TC\u003c\/p\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis cable employs three XHHW insulated copper phase conductors and one bare copper ground wire.  Each individual conductor is insulated\n                with a cross-linked polyethylene jacket.  The class B stranded copper cables in this product allow greater flexibility than class\n                A or AA copper.  The XHHW describes the insulation that jackets each individual phase conductor.  XHHW stands for Cross-linked\n                High Heat resistant and Water resistant.  XHHW is one of this most durable insulation types on the market and protects the cables\n                from abrasion, heat, dryness, moisture and wetness, corrosive gasses and liquids, and other corrosive materials.  The assembly is\n                altogether jacketed in a black PVC armor to further protect the conductors from corrosion and interference.\u003c\/p\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\n            \u003c\/p\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis cable is extremely resilient and is approved for use in hazardous locations.  It is most commonly used in industrial applications\n                and to supply power to motors.  The flame retardant insulation passes the Underwriters Laboratories Flame Test IEEE-383, a test that\n                requires the product to be able to stand up to flames up to 70,000 BTU.  It’s flame resistant qualities make the XHHW cable a cable\n                of choice for use in areas with a high risk of fire.  The cable is approved for direct burial and can also be installed in open air\n                with support by messenger wire as well as in conduit or duct. \u003c\/p\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\n            \u003c\/p\u003e\n            \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n                \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100\n                    years ago, this cable meets UL Standard 44.  This standard is designed to ensure thermoset conductors are capable of carrying\n                    at least 600 volts and exhibit the ability to function at temperatures up to 90°C.\u003c\/li\u003e\n                \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe cable also is in alignment with UL Standard 1277 and UL Standard 1581, standards that ensure the ground cable is present and also that\n                    the assembly can function efficiently in wet or dry locations.\u003c\/li\u003e\n                \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product adheres UL Standard 1685, a standard that requires thermoset conductors to pass a Flame Exposure Test.\u003c\/li\u003e\n                \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eIn addition to meeting specifications of UL Standard 1685, this cable also passes the IEEE-383 Flame Test as well as the ICEA T-29-520\n                    Vertical Cable Tray Flame Test.\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\n            \u003c\/p\u003e\n            \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n                \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 1in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.5in;\"\u003e-           This product employs the high conductive power of soft annealed copper. \n                Copper is often preferred over its aluminum counterpart because it is more resistant to corrosion and remains stable over a longer course\n                of time.\u003c\/p\u003e\n            \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n                \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 1in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.5in;\"\u003e-           Copper conductors are concentric lay stranded.  The helical design -provides\n                greater flexibility than solid copper.\u003c\/p\u003e\n            \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n                \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eInsulation\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 1in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.5in;\"\u003e-           The copper conductors are individually insulated in cross-linked polyethylene. \n                This insulation protects the conductors from interference and corrosion due to excessive wetness or dryness, heat, sunlight, and corrosive\n                gasses or liquids.  The insulation is colored black and is numbered for identification.\u003c\/p\u003e\n            \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n                \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eOuter Jacket\u003c\/li\u003e\n            \u003c\/ul\u003e\n            \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 1in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.5in;\"\u003e-           The PVC outer jacket serves as the first line of defense to the electrical components\n                of the cable.  The outer jacket prevents abrasion to the conductors and also helps defend the conductors from weather and other corrosive\n                elements. \u003c\/p\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eName:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003eXHHW 750 MCM\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e3\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e1\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e750\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e61\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e2.710\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\n                        \u003c\/td\u003e\n                        \u003ctd\u003e9010\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160538005567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-copper-tray-cable-tc_a9a659f1-4af2-4260-8244-e1e85d6ff6bc.jpg?v=1571727710","url":"https:\/\/nassauelectricalspot.com\/products\/750-3-w-grnd-xhhw-tray-cable","provider":"NassauElectrical","version":"1.0","type":"link"}