{"product_id":"350-4-w-grnd-pvc-jacket-pvc","title":"350-4 W\/GRND PVC JACKET PVC","description":"350-4 W\/GRND PVC JACKET PVC\u003cmeta name=\"Description\" content=\"The 350-4 W\/GRND PVC Jacket PVC cable combines versatile THHN\/THWN approved conductor with aluminum interlocked armor plus an added polyvinyl chloride jacket.  THHN copper conductors are Thermoplastic High Heat-resistant Nylon coated.\"\u003e\u003cmeta name=\"Keywords\" content=\"Armorlite Type MC 350-4 W\/GRND PVC Jacketed PVC Cable,THHN Coper Conductor Cable,THWN Copper Conductor Cable,Copper Conductor Cable,Aluminum interlocked Armor Cable,Armorlite Cable,Insulated Conductor Cable,Armored Cables,Jacketed Cables\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eArmorlite Type MC PVC Jacketed Copper Conductors\u003c\/p\u003e\n\u003cp\u003eThe 350-4 W\/GRND PVC Jacket PVC cable combines versatile THHN\/THWN approved conductor with aluminum interlocked armor plus an added polyvinyl chloride jacket.  THHN copper conductors are Thermoplastic High Heat-resistant Nylon coated.  The acronym mainly refers to the nylon insulation that protects the cable from high heat and corrosion.  With the added THWN approval, the cable is also deemed as water resistant.  The assembly includes an insulated copper stranded grounding conductor to ensure steady conductivity over the life of the cable.  The assembly of conductors is cabled together and wrapped in binder tape to sit firmly in place.  The assembly is then encased in an aluminum interlocked armor that protects the conductors from being jarred or interfered with by outside objects.  The exterior armor is coated with a polyvinyl chloride (PVC) jacket that is sunlight and moisture resistant. \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 12pt;\"\u003eThe 350-4 W\/GRND PVC Jacket PVC cable is designed for installation in branch, feeder, and service power distribution.  The cable can be used in residential, multi-residential, institutional, industrial, and commercial buildings.  It is most often used for control, power, lighting, and signal circuits where maximum ampacity is required.  The cable is usually installed in cable tray or approved raceways but can also be fished or embedded in plaster.  The cable is approved for use in hazardous locations as specified by NEC.  The cable has a maximum conductor temperature for continuous operation at 90°C and can transmit ampacities up to 600 volts. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is the jacketed version of the Southwire Armorlite® Type MC Cable.  This cable combines versatile THHN\/THWN approved conductor with aluminum interlocked armor plus an added polyvinyl chloride jacket.  THHN copper conductors are Thermoplastic High Heat-resistant Nylon coated.  The acronym mainly refers to the nylon insulation that protects the cable from high heat and corrosion.  With the added THWN approval, the cable is also deemed as water resistant.  The assembly includes an insulated copper stranded grounding conductor to ensure steady conductivity over the life of the cable.  The assembly of conductors is cabled together and wrapped in binder tape to sit firmly in place.  The assembly is then encased in an aluminum interlocked armor that protects the conductors from being jarred or interfered with by outside objects.  The exterior armor is coated with a polyvinyl chloride (PVC) jacket that is sunlight and moisture resistant. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is designed for installation in branch, feeder, and service power distribution.  The cable can be used in residential, multi-residential, institutional, industrial, and commercial buildings.  It is most often used for control, power, lighting, and signal circuits.  The cable is usually installed in cable tray or approved raceways but can also be fished or embedded in plaster.  The cable is approved for use in hazardous locations as specified by NEC.  The cable has a maximum conductor temperature for continuous operation at 90°C and can transmit ampacities up to 600 volts. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this cable aligns with UL standard 83, a specification for single conductor thermoplastic insulated cables transmitting 600 volts.\u003c\/li\u003e\n\u003cli\u003eThis cable complies with UL standard 1569; a specification that requires metal clad cable to perform up to expectations under specified ampacities and conductor temperatures.\u003c\/li\u003e\n\u003cli\u003eThe cable meets or exceeds UL standard 1685, passing a Vertical-Tray Fire-Propagation and Smoke-Release Test. \u003c\/li\u003e\n\u003cli\u003eThe cable complies with Federal Specification A-A59544.\u003c\/li\u003e\n\u003cli\u003eThe cable is listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstructions:\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt;\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable employs THHN\/THWN insulated copper conductors.\u003c\/li\u003e\n\u003cli\u003eTHHN\/THWN conductors are high heat and water resistant, making them safe for use in wet or dry locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt;\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Wire\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes an insulated ground wire.\u003c\/li\u003e\n\u003cli\u003eThe ground wire ensures steady conductivity for the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt;\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe external armor is an aluminum interlocked armor.\u003c\/li\u003e\n\u003cli\u003eThe armor keeps the conductors from being jarred or interfered with by outside objects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt;\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe outer armor is coated in a PVC jacket that is sunlight and moisture resistant. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Conductor Size AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Neutral Messenger Size AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Bare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Steel Core (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5493\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 75C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 90C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160440520767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/99_38e89d17-2a72-4cee-a768-e134bf65455b.jpg?v=1684225484","url":"https:\/\/nassauelectricalspot.com\/products\/350-4-w-grnd-pvc-jacket-pvc","provider":"NassauElectrical","version":"1.0","type":"link"}