{"product_id":"350-3-w-grnd-vntc-tray-cable","title":"350-3 W\/GRND VNTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eVNTC Type TC Tray Cable 600Vbreezes through fire tests controlled by UL, ICEA and CSA. The link passes UL 1277, IEEE 383, IEEE 1202 and CSA FT4 fire tests. These tests measure a link's capacity to repel blazes at different separations and intensities. VNTC is a prevalent link in areas with a high danger of flame. Temporary workers and circuit repairmen normally lean toward fire resistant links much of the time in light of the fact that there are relatively few circumstances where fire is not a probability. A fire resistant link expands the chance that the link will be salvageable after a disaster, and all the more critically, is a sheltered link that won't make much more harm by being presented to fire. This current link's development permits it to be utilized as a part of wet or go areas in temperatures away to 90°C when dry, 75°C when wet. The link has a chilly twist rating of - 20°C and meets pulverize and affect prerequisites of Type MC link. The link passes UL, IEEE, and CSA fire tests and is in this manner considered appropriate for use in unsafe areas. The link offers incredible imperviousness to oil, so it is regularly utilized as a part of engine leads or oil boring applications. The VNTC Type TC Tray Cable 600V can be utilized as a part of direct internment applications, free air, or introduced in raceways or course. VNTC link's icy curve rating of - 20°C makes it a decent link for use in many areas. The link can be presented to extreme temperature changes and won't change shape or usefulness. 350-3 W\/GRND VNTC Tray Cable has 3 350AWG conductors tethered together to be able to connect up to three cables at once.  Even when it is not used in conduit, the cable offers amazing resistance properties to dangerous components. More often than not, it is introduced in flame resistant, waterproof pipes to boost its resistance, making it a to a great degree durable link.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSearch Terms:  \u003c\/strong\u003e350-3 W\/GRND VNTC Tray Cable, 350 AWG cable, multiconductor cable, water-resistant cable, water resistant cable, cold bend cable, cold resistant cable, fire resistant cable, Flame resistant cable, fire-resistant cable, flame-resistant cable, UL rated cable, CSA rated cable, triple conductor cable, FT4 Flame Test, oil resistant cable, oil-resistant cable, conduit cable, raceway cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegulations:\u003c\/strong\u003e \u003cbr\u003e \u003cstrong\u003eUL 66  - \u003c\/strong\u003eA UL standard that evaluates and sets specifications for the construction of fixture wires.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEC Type TFN Conductors–\u003c\/strong\u003e600-volt fixture wire that has been evaluated by the NEC.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUL 1277 Type TC-ER for 3 or more conductors - \u003c\/strong\u003eSets requirements cover electrical power and control cables consisting of either two or more current-carrying copper, aluminum, or copper-clad aluminum circuit conductors, or one or more pairs of thermocouple-extension wires.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUL 1581 - \u003c\/strong\u003eA standard contains specific details of the conductors, of the insulation, of the jackets and other coverings, and of the methods of sample preparation, of specimen selection and conditioning, and of measurement and calculation that are required in wire and cable standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICEA S-95-658 - \u003c\/strong\u003eThis standard applies to materials, constructions, and testing of 2000 volts and less thermoplastic, crosslinked polyethylene, and crosslinked rubber insulated wires and cables which are used for the transmission and distribution of electrical energy for normal conditions of installation and service, either indoors, outdoors, aerial, underground, or submarine.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUL 1277 - \u003c\/strong\u003eSets requirements cover electrical power and control cables consisting of either two or more current-carrying copper, aluminum, or copper-clad aluminum circuit conductors, or one or more pairs of thermocouple-extension wires.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEEE 383 - \u003c\/strong\u003eStandard for qualifying electric cables and splices for nuclear facilities.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEEE 1202 - \u003c\/strong\u003eA test protocol and the performance criteria to determine the flame propagation tendency of cables in a vertical cable tray. \u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCSA FT4 - \u003c\/strong\u003e70,000 BTU flame test for cables used in trays should burn the cables for 20 minutes and not exceed 1.5 meters after the test is finished.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeets EPA 40 CFR, Part 261 for leachable lead content per TCLP method\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOSHA acceptable\u003c\/strong\u003e– Cable is approved for safety and efficiency by Occupational Safety and Health Administration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003ePolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:  \u003c\/strong\u003eCoated with nylon\u003cstrong\u003e, \u003c\/strong\u003epolyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:  \u003c\/strong\u003e100% annealed stranded tinned copper. Aligns with ASTM B33, B8.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e226430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW15435003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNexans item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e665042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOmni Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA335003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSouthwire item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e443507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuperior Essex item Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE3BEA-A31B03CE00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160438390847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-tray-cable-new_2df38801-64bd-4c12-8dcf-32d3c9ced561.jpg?v=1571727674","url":"https:\/\/nassauelectricalspot.com\/products\/350-3-w-grnd-vntc-tray-cable","provider":"NassauElectrical","version":"1.0","type":"link"}