{"product_id":"3-4-3-w-grnd-xhhw-tray-cable","title":"3\/0-4 W\/GRND XHHW Tray Cable","description":"\u003ctrstyle\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eXHHW Power Cable – 4 Conductor with Ground – Type TC\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eFour XHHW insulated copper phase conductors and a bare copper ground wire make up this cable.  XHHW is a reference to the insulation that coats each phase conductor.  The acronym stands for Cross-linked High Heat resistant and Water resistant.  XHHW’s proven durability to resist abrasion, heat, dryness, moisture and wetness, corrosive gasses and liquids, and other corrosive materials. Each individual conductor is insulated with a cross-linked polyethylene jacket.  The assembly is altogether jacketed in a black PVC armor to further protect the conductors from corrosion and interference.  Class B stranded copper is used to make up the conductors in this product.  This type of copper offers better flexibility than class A or AA copper. \u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis cable can be used in a variety of applications and installations including duct and conduit, open air with support by messenger wire, and direct burial.  The product can be used in wet or dry locations in temperatures not to exceed 90°C.  This cable is a favorite for use in industrial applications because if its durability and flame resistant qualities.  The flame retardant insulation passes flame tests administered by Underwriters Laboratories.  The cable is often used to supply power to motors as well. \u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable meets UL Standard 44.  This standard is designed to ensure thermoset conductors are capable of carrying at least 600 volts and exhibit the ability to function at temperatures up to 90°C.\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe cable also is in alignment with UL Standard 1277 and UL Standard 1581, standards that ensure the ground cable is present and also that the assembly can function efficiently in wet or dry locations.\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product adheres UL Standard 1685, a standard that requires thermoset conductors to pass a Flame Exposure Test.\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eIn addition to meeting specifications of UL Standard 1685, this cable also passes the IEEE-383 Flame Test as well as the ICEA T-29-520 Vertical Cable Tray Flame Test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003e \u003c\/span\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 1in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.5in;\"\u003e-           This product employs the high conductive power of soft annealed copper.  Copper is often preferred over its aluminum counterpart because it is more resistant to corrosion and remains stable over a longer course of time.\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 1in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.5in;\"\u003e-           Copper conductors are concentric lay stranded.  The helical design -provides greater flexibility than solid copper.\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 1in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.5in;\"\u003e-           The copper conductors are individually insulated in cross-linked polyethylene.  This insulation protects the conductors from interference and corrosion due to excessive wetness or dryness, heat, sunlight, and corrosive gasses or liquids.  The insulation is colored black and is numbered for identification.\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eOuter Jacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 1in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.5in;\"\u003e-           The PVC outer jacket serves as the first line of defense to the electrical components of the cable.  The outer jacket prevents abrasion to the conductors and also helps defend the conductors from weather and other corrosive elements. \u003c\/p\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eName:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXHHW 3\/0 Gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.590\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160434917439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-copper-tray-cable-tc_142fb71a-3738-445d-b810-a5474b59032c.jpg?v=1571727673","url":"https:\/\/nassauelectricalspot.com\/products\/3-4-3-w-grnd-xhhw-tray-cable","provider":"NassauElectrical","version":"1.0","type":"link"}