{"product_id":"3-0-3-xhhw-w-grnd-mc","title":"3\/0-3 XHHW W\/GRND MC","description":"3\/0-3 XHHW W\/GRND MC\u003cmeta name=\"Description\" content=\"This cable utilizes uncoated soft copper conductors that align with specifications set forth by the American Society of Testing and Materials standard B-3, B-8 for compressed stranded conductors, and B-496 for compact stranded conductors.  \"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor UL  Type MC 3\/0-3 XHHW W\/GRND MC Cable ,Copper Conductors, XHHW-2 Conductors, Insulated Cables,Type MC Cables,Interlocked Armor Cable,Armor Cable,XHHW-2 Cable,Power Cable,Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor UL Type MC Copper XHHW-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable utilizes uncoated soft copper conductors that align with specifications set forth by the American Society of Testing and Materials standard B-3, B-8 for compressed stranded conductors, and B-496 for compact stranded conductors.  The conductors are insulated with a cross-linked polyethylene rubber that adds mechanical strength to the cable and protects the conductors from corrosion.  Among the assembly of conductors is an uninsulated bare stranded copper grounding wire.  The grounding wire keeps the cable grounded for steady conductivity over the life of the cable.  Fillers and binder tape are included as necessary to keep the assembly firmly in place.  The assembly of conductors is encased in an aluminum interlocked armor that is also available in galvanized steel.  The external armor keeps the conductors safe from being jarred or interfered with by outside objects.  The armor is coated with a black polyvinyl chloride jacket that serves as a sunlight, flame, and moisture-resistant outer skin.  The interlocked armor system on this cable makes it a great economical alternative to wire installed in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor UL Type MC Copper XHHW-2 cable is intended for use in branch circuits, power distribution systems, and feeders.  It can be safely installed in exposed or concealed areas in wet or dry locations.  The cable is safe for direct burial applications and it can be embedded in concrete.  It may also be installed in cable trays troughs, metal racks, or supports.  When installing with supports, supports should be spaced no more than 6 feet apart.  This cable is deemed safe for use in hazardous locations as specified by NEC.  The cable offers excellent impact and crush resistance and its flexibility allows it to be easily re-routed. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriter Laboratories, a compliance and regulations organization, this cable aligns with UL standard 1569; a standard that measures the abilities of Type MC metal-clad cables.\u003c\/li\u003e\n\u003cli\u003eThis cable passes the vertical tray flame test requirements of IEEE 383-1974 and 1202-1991.\u003c\/li\u003e\n\u003cli\u003eThe cable passes ICEA T-29-520 standard, passing 210,000 BTU\/hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components in this cable are uncoated soft copper conductors.\u003c\/li\u003e\n\u003cli\u003eThe copper conductors align with specifications set forth by the American Society of Testing and Materials standard B-3, B-8 for compressed stranded conductors, and B-496 for compact stranded conductors. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with a cross-linked polyethylene rubber that adds mechanical strength to the cable and protects the conductors from corrosion. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a bare stranded copper ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor keeps the phase conductors transmitting steadily over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable fillers and binder tape are used to ensure that the assembly of conductors sits firmly in place inside the exterior armor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are encased by an interlocked aluminum armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe external armor keeps the conductors safe from being jarred or interfered with by outside objects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is coated with a  polyvinyl chloride jacket that is flame, sunlight, and moisture resistant. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Conductor Insulation Thickness:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 mls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Aluminum Armor (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Galvanized Armor (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity 90C (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160430460991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-interlocked-armor-mv-90-cables_cf2fd6e2-e025-4d7b-8ee6-6b369cac5dd1.jpg?v=1571727672","url":"https:\/\/nassauelectricalspot.com\/products\/3-0-3-xhhw-w-grnd-mc","provider":"NassauElectrical","version":"1.0","type":"link"}