{"product_id":"2-0-5kv-epr-hypalon-mv-90-non-shielded","title":"2\/0 5kV EPR Hypalon MV-90 Non Shielded","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-family: calibri;\"\u003eEPR-PVC 5kV Unshielded Type MV90 Power Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003eThe EPR-PVC Type MV-90 cable features a Class B concentrically stranded copper conductor that bears ethylene propylene (EPR) insulation and an external polyvinyl chloride (PVC) jacket.  The copper conductor is an uncoated annealed copper.  The process of annealing the copper makes the softens the metal and makes the product more flexible without compromising the copper’s powerful conductive properties.  The EPR insulation helps to stabilize the conductor’s current while providing mechanical strength and durability to the cable.  Directly covering the insulation layer is the PVC jacket,\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003eThe Type MV-90 cable is designed to transmit medium voltages (5,000 Volts) and can function in temperatures up to 90°C.  With a high tolerance for extreme temperatures and the ability to perform in wet and dry conditions, this cable can be used in many different applications.  The cable can be installed in tray, trough, conduit, ducts, strung aerially, or directly buried when in compliance with NEC specifications.  The cable is widely used in commercial, industrial, and electric utility operations as branch circuits, distribution, and main feeder cable. \u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis cable meets requirements set forth by Underwriters Laboratories, classifying the cable as Type MV-90.  This classification, as indicated by the MV-90 acronym, certifies the cable is safe to transmit medium voltages of up to 5,000 volts and can function continuously in temperatures up to 90°C. \u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eEthylene propylene components of this cable conform to ICEA pub no. S-68-516 and NEMA pub no. WC8.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eConstruction:\u003c\/span\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eConductors\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe conductive components of this cable are made with Class B stranded annealed uncoated copper.  Copper is an extremely powerful conductor and when the annealing process is applied, the conductor becomes more malleable; an admired quality in most applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eInsulation\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe Class B copper conductor is insulated by ethylene propylene rubber (EPR).  This insulation helps to stabilize the conductive current and add mechanical strength to the overall assembly. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eJacket\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe exterior PVC jacket serves as the cable’s first line of defense against corrosion to the conductors.  The PVC jacket is flame-retardant and it is resistant to sunlight and moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity Dwelling (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160350343231,"sku":"","price":8.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-epr-medium-voltage-cables_a756ef80-ff35-4f40-8334-2b1e89cd0158.jpg?v=1571727644","url":"https:\/\/nassauelectricalspot.com\/products\/2-0-5kv-epr-hypalon-mv-90-non-shielded","provider":"NassauElectrical","version":"1.0","type":"link"}