{"product_id":"16-20-vntc-tray-cable","title":"16\/20 VNTC Tray Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003eThis multi-conductor cable employs Class B, fully annealed stranded tinned copper conductors.  The copper conductors align with ASTM standards B33 and B8.  The annealed copper product used in this cable offers superior flexibility compared to standard copper conductors.  The annealed metal undergoes a process in which the copper is heated and then slowly cooled, removing internal stress to make the copper more malleable.   The VNTC Type TC Tray Cable is available with Type THHN or THWN conductors.  THHN conductors are high heat-resistant, while THWN offers heat resistance and water resistance as well.  The copper conductors are insulated in polyvinyl chloride (PVC) insulation that bears a clear polyamide (nylon) coat.  An exterior PVC jacket encases the conductors and protects them from abrasion and corrosion due to flame, moisture, oil, sunlight, ozone, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable’s construction allows it to be used in wet or dry locations in temperatures up to 90°C when dry, 75°C when wet.  The cable has a cold bend rating of -20°C and meets crush and impact requirements of Type MC cable.  The cable passes UL, IEEE, and CSA flame tests and is therefore deemed suitable for use in hazardous locations.   The cable offers great resistance to oil, so it is often used in motor leads or oil drilling applications.  The VNTC Type TC Tray Cable can be used in direct burial applications, free air, or installed in raceways or conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization established over 100 years ago, this cable adheres to UL standard 66 which states construction, testing, and marking requirements for fixture cables.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable also aligns with UL standard 1277 for Type TC-ER cables with three or more conductors.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets or exceeds UL 1581 requirements for jacketed conductors.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe VNTC Type TC Tray Cable is acceptable by the Occupational Safety and Health Administration.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis cable passes the following flame tests: UL 1277, IEEE 383, IEEE 1202, and CSA FT-4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis multi-conductor cable employs Class B, fully annealed stranded tinned copper conductors. \u003c\/li\u003e\n\u003cli\u003eThe copper conductors align with ASTM standards B33 and B8. \u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe VNTC Unshielded Tray cable is available with Type THHN or THWN conductors.\u003c\/li\u003e\n\u003cli\u003eTHHN conductors are high heat-resistant, while THWN offers heat resistance and water resistance as well. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe copper conductors are insulated in polyvinyl chloride (PVC) insulation that bears a clear polyamide (nylon) coat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAn exterior PVC jacket encases the conductors and protects them from abrasion and corrosion due to flame, moisture, oil, sunlight, ozone, and chemicals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160308269119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-Tray-Cable_976d6aa1-6ed3-48be-ab8c-b78f427e0e68.jpg?v=1571727625","url":"https:\/\/nassauelectricalspot.com\/products\/16-20-vntc-tray-cable","provider":"NassauElectrical","version":"1.0","type":"link"}