{"product_id":"1000mcm-5-8kv-power-cable-115-mils","title":"1000MCM 5-8kV Power Cable 115 Mils","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e5kV-8kV Type MV-105 - 115 Mils EPR with PVC Jacket\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003eThe conductive component of this cable is a concentric compact stranded class B copper conductor.  The class B copper in this cable is annealed to make the conductor softer and more malleable.  The conductor is covered by triple single head extruded conductor shield.  The conductor shield is then insulated with a dry cured ethylene propylene insulation that bears an easy strippable bare copper insulation shield.  The bare copper insulation shield is made of 5 mils annealed copper with an overlap of 25%.  A black, surface printed polyvinyl chloride (PVC) jacket serves as the external layer of the cable.  The exterior jacket is flame-retardant and moisture and sunlight resistant. \u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003eThis cable is used in distribution, main feeder and branch circuits for commercial, industrial, and electric utility installations.  The cable can be installed in aerial applications, direct burial, conduit open tray, and underground duct installations. \u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003eWhen installed in accordance with NEC regulations, the cable is safe for use in wet or dry locations.  For direct burial applications, ensure the cable is installed in a system with a ground conductor that is in close proximity with NEC 250.4(A)(5).  Under normal operating conditions, this cable is able to function at temperatures up to 105°C.  At emergency operating conditions, the cable can tolerate temperatures up to 140°C.  In short circuit situations, the cable has a temperature rating of 250°C. \u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eIn accordance with standards set forth by Underwriters Laboratories, this product meets or exceeds UL standard 1072.  This standard sets the expectations for shielded and unshielded. Specifications require this cable to be able to function at temperatures. \u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis cable is Underwriters Laboratories listed as Type MV-105. MV-105 stands for the voltage (Medium Voltage) and the maximum operating temperature (105°C).\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis cable meets UL standard 1685.  This standard required the product to pass a flame exposure test in which the total smoke released is to be 95 m2 or less and the peak smoke release rate is to be 0.25 m2\/s or less.  The cable char height is to be less than 8 ft, 0 inch (244 cm) when measured from the bottom of the cable tray in accordance with Section 8.\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe cable passes the IEEE 1202 flame test, a test designed to measure the flame resistance qualities of cable in cable tray.\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis cable is deemed acceptable by Occupational Safety and Health Administration. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eConductor\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe conductive component of this cable is a concentric compact stranded class B copper conductor.  The class B copper in this cable is annealed to make the conductor softer and more malleable.\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eExtruded Strand Shield\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe extruded thermoset semi-conducting strand shield is a layer over the conductor that controls stress on the conductor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eInsulation\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe cable is insulated with Ethylene Propylene Rubber insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eExtruded Insulation Shield\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe extruded insulation shield is a thermoset semi-conducting polymeric layer free stripping from insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eMetallic Shield\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe metallic shield is a copper tape that covers the insulation.  The tape is 5 mils annealed copper with an overlap of 25%.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 20px 1in; font-family: lato, helvetica, arial, sans-serif; line-height: 1.6; color: #475054; font-size: 16px; text-indent: -0.5in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e \u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: bold;\"\u003eJacket\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: lato, sans-serif; color: #475054; font-size: 16px; line-height: 22.4px;\"\u003e\n\u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThe outer jacket is a black PVC jacket.  The PVC jacket is flame-retardant and moisture and sunlight resistant. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Over Insulation (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Over Insulation Shield (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity 1\/C in Cable Tray (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity 1\/C Conduit in Air (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e755\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity in Ducts (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160215568447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-5-35kV_7ed4573f-ffa0-41bd-a0e5-886005a31ff3.jpg?v=1571727595","url":"https:\/\/nassauelectricalspot.com\/products\/1000mcm-5-8kv-power-cable-115-mils","provider":"NassauElectrical","version":"1.0","type":"link"}