{"title":"Type UF \/ NMC-B Cable, 600 Volt, 2 and 3 Conductor With or Without Ground","description":"","products":[{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground","title":"Type UF\/NMC-B Cable 600 Volt, Multi Conductor With or Without Ground","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eUF\/NMC-B is Type UF cable which is an underground power transmission cable with two or three phase conductors. The cable may or may not be fitted with a ground wire depending on the type of application anticipated. The high ampacity of 600v and the copper conductor gives the cable optimum and stable conductivity, drawing high electric power over time.\u003c\/p\u003e\n\u003cp\u003eThe conductors are individually insulated and then an overall jacket is put to maintain the dryness required in underground environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eThis Type UF cable is basically constructed for underground applications. It is applicable for both industrial and do-it-yourself home applications. Below are the applications;\u003cbr\u003e• Underground power distribution\u003cbr\u003e• Applications involving direct burial\u003cbr\u003e• Used in wiring branch circuits below or above ground\u003cbr\u003e• Wet and dry locations\u003cbr\u003e• corrosive locations\u003cbr\u003e• Cable trays\u003cbr\u003e• Concealed and exposed interior wiring\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e• Fully annealed soft copper conductor; optimum and stable conductivity\u003cbr\u003e• Available in two or three phase conductors\u003cbr\u003e• A single ground copper wire or none at all\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e• Lead free Polyvinyl Chloride, PVC insulator\u003cbr\u003e• Individual conductor insulation\u003cbr\u003e• Dry insulator with water and moisture resistance\u003cbr\u003e• Individual insulation with color codes for easy identification\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacketing:\u003c\/strong\u003e\u003cbr\u003e• PVC armor individual conductor jacketing.\u003cbr\u003e• An overall PVC armor jacket\u003cbr\u003e• The PVC jacket has excellent dryness with high resistance to water and moisture\u003cbr\u003e• Good resistance to fungus and bites from underground organisms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003cbr\u003eThere are two types of stranding used for Type UF cable;\u003cbr\u003e• Compressed stranding technique; used for high flexibility applications.\u003cbr\u003e• The solid wire technique; is preferred for outdoor hazardous ground applications because of its low surface area exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e• Type UF\/NMC Cable\u003cbr\u003e• Excellent resistance to fungus and insect bites\u003cbr\u003e• Lead free\u003cbr\u003e• 600V ampacity\u003cbr\u003e• 60°C temperature rating\u003cbr\u003e• Water and moisture resistance\u003cbr\u003e• Resistance to UV and weather\u003cbr\u003e• Applicable in both wet and dry environments\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e• UL Listing\u003cbr\u003e• OSHA approved\u003cbr\u003e• National Electrical Code (NEC) article 336 and 339.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor Size AWG\u003c\/td\u003e\n\u003ctd\u003eno. of Isolated conductors\u003c\/td\u003e\n\u003ctd\u003eCable Weight lb\/mft\u003c\/td\u003e\n\u003ctd\u003eAmpacity (1) 40 Degrees C\u003cbr\u003e Ambient Temp\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e123\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-4-awg\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-4-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-2-awg\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-2-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-1-0-awg\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-1-0-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-2-0-awg\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e508\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-2-0-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-3-0-awg\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e634\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-3-0-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-4-0-awg\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-4-0-awg\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-4-0-awg-2-conductors\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-4-0-awg-2-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-2-conductors\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-2-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-2-conductors\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-2-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-2-conductors\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-2-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-2-conductors\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e326\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-2-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-3-conductors\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-3-conductors\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-3-conductors\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e172\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-3-conductors\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e308\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-3-conductors\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e469\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-3-conductors\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-2-conductors-14-ground-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e78\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-2-conductors-14-ground-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-2-conductors-12-ground-\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-2-conductors-12-ground-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-2-conductors-10-ground-\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-2-conductors-10-ground-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-2-conductors-10-ground-s\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-2-conductors-10-ground-s\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-2-conductors-10-ground-s\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e383\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-2-conductors-10-ground-s\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-3-conductors-14-ground-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-3-conductors-14-ground-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-3-conductors-12-ground-\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-3-conductors-12-ground-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-3-conductors-10-ground-\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e218\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-3-conductors-10-ground-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-3-conductors-10-ground-s\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e346\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-3-conductors-10-ground-s\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-3-conductors-10-ground-s\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/submersible-pump-cable\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-3-conductors-10-ground-s\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163677376575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-1-0-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 1\/0 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\/.0745\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.573\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.544\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163677802559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_a655d512-c8bc-4781-bfff-db086ad490e2.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163677900863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_b2ede23a-fa43-4483-8ded-fce1f518a98b.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-2-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.240 x .475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.096 x 12.065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163677933631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_048baac1-266c-4710-b156-cff4d6e748b5.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-2-conductors-10-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG - 2 Conductors - 10 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.240 x .570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.096 x 14.478\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163678031935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_311d0d48-01fb-492c-a101-3431d5e1c047.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-3-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.245 x .700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.223 x 17.78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e172\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163678064703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_04b7bdbc-7b4c-43e7-9450-fa93268e1378.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-10-awg-3-conductors-10-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 10 AWG - 3 Conductors - 10 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.245 x .800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.223 x 20.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163678982207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_3acb5e73-61dc-49af-ba17-b0cbbbb6ea84.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163680587839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_354f1a32-699e-408c-9d5e-37b8a4145393.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-2-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.220 x .445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.588 x 11.303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163681407039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_d9eb24f0-6d7f-448c-8735-9dff220dc507.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-2-conductors-12-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG - 2 Conductors - 12 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.235 x .495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.969 x 12.573\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163681505343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_af81e16f-2a9a-44ee-b722-799166780ca7.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-3-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.215 x .640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.461 x 16.256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163681538111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_0b148b40-993d-4a9b-83d8-802a6f294896.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-12-awg-3-conductors-12-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 12 AWG - 3 Conductors - 12 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.225 x .720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.7150 x 18.288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163681570879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_83e218d8-7181-4758-8b8b-bf7fcbb1da12.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.188\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163681931327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_f51ed97c-984f-4042-bf99-7408b4f1e6a2.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-2-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.210 x .435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.334 x 11.049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163682259007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_ef938bc1-44f7-48aa-a580-443883028dd3.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-2-conductors-14-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG - 2 Conductors - 14 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.210 x .445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.334 x 11.303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163684192319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_cf761aea-a59f-4f00-bb6f-9872e329308a.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-3-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.210 x .600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.334 x 15.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685273663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_eed69f41-9e66-4ce2-98fb-6a2bbbba976f.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-14-awg-3-conductors-14-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 14 AWG - 3 Conductors - 14 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.210 x .650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.334 x 16.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685306431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_1534698b-7304-4d58-8f42-e22378ef7e19.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-2-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 2 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0972\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.684\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685404735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_ecf941f0-6808-47c9-ac61-346e12641591.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-2-0-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 2\/0 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\/.0837\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.697\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685437503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_df3339d7-774b-456c-99ac-7726900dee81.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-3-0-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 3\/0 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\/.0940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685535807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_44ae6a82-b696-4951-847e-240aaef9a73f.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-4-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 4 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0772\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685601343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_2dceaa5e-1e8d-4e2b-bebb-8838cf77bb05.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-4-0-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 4\/0 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\/.1055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685699647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_da56dddc-9524-46ca-9094-b1af18ab9e9f.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685732415,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_1ab96d28-8f3f-4985-9546-31ab6908fde7.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-2-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.410 x .900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.414 x 22.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685830719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_5e6b10e3-29e0-4e30-8cd9-e51b6e0f40d0.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-2-conductors-10-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG - 2 Conductors - 10 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.410 x .900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.414 x 22.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e383\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685863487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_bc6c526c-8e37-4d57-bc9e-62fd65930337.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-3-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.415 x 1.260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.541 x 32.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e469\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163685929023,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_d0880737-49e9-4463-b593-e8e3ff3cd65c.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-6-awg-3-conductors-10-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 6 AWG - 3 Conductors - 10 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163686027327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_c530b1c7-6f52-4d8e-97c7-e5d2d920b5ed.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.296\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.518\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163686060095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_5ffb1169-45aa-4166-86f7-b58bc58f55e5.jpg?v=1571728295"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-2-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.340 x .700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.636 x 17.780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163686092863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_30a9633a-3c72-4e2d-b1e4-78538b233725.jpg?v=1571728309"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-2-conductors-10-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG - 2 Conductors - 10 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.340 x .700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.636 x 17.780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163686715455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_59c31e2a-0359-4a4b-a61c-0a20b6a87627.jpg?v=1571728309"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-3-conductors","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.345 x 1.040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.763 x 26.416\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163686846527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_00b59cd4-72ac-4a80-9813-868763eb3acc.jpg?v=1571728309"},{"product_id":"type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground-8-awg-3-conductors-10-ground-size-awg","title":"TYPE UF \/ NMC-B CABLE, 600 VOLT, 2 AND 3 CONDUCTOR WITH OR WITHOUT GROUND - 8 AWG - 3 Conductors - 10 Ground Size AWG","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 392px;\"\u003e\u003cstrong\u003eConductor Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 142px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Insulated Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Conductor Stranding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\/.0486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.345 x 1.040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable O.D. (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7630 x 26.416\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight lb\/mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity UF or NMC-B 60 Degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE UF \/ NMC-B CABLE\u003c\/li\u003e\n\u003cli\u003e600 VOLT, 2 AND 3 CONDUCTOR\u003c\/li\u003e\n\u003cli\u003eWITH OR WITHOUT GROUND\u003c\/li\u003e\n\u003cli\u003e60°C Dry\/Wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e UL Listed and OSHA acceptable. In accordance with Articles 336 and 339 of the National Electrical Code (and subject to local code requirements), Type UF cables may be used for underground feeder or branchcircuit wiring for installation above or below ground, including direct burial, and in wet or corrosive locations. Multi-conductor Type UF (Type NMC-B) cables may also be used for exposed or concealed interior wiring in wet, dry or corrosive locations and in cable trays\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJACKET:\u003c\/strong\u003e\u003cbr\u003e POLYVINYL CHLORIDE (PVC)\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163686944831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/P7295-SP-lg_8ebfd0b1-695b-4d08-b4e5-d096c30d440a.jpg?v=1571728309"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/type-uf-nmc-b-cable-600-volt-2-and-3-conductor-with-or-without-ground.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}