{"title":"Type SHD-GC-8kV","description":"","products":[{"product_id":"type-shd-gc-8kv","title":"Type SHD-GC-8kV","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our TYPE SHD-GC-8KV Cable. This cable is suitable for installation in Ducts, troughs, tray or direct burial for Non Flexing service.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable, EPR CPE Cable 8KV, TYPE SHD-GC 8KV Cable, XLPE Cable 8KV.\"\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cspan style=\"font-size: 11px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 11px; color: #ffffff;\"\u003eSize\u003cbr\u003e (AWG or KCMIL)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003eNumber of Conduc\u003cbr\u003e-tors in Cable\u003c\/td\u003e\n\u003ctd style=\"text-align: center; border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cspan style=\"font-size: 11px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 11px; color: #ffffff;\"\u003eDiameter Complete Cable (O.D.) (Inches)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cspan style=\"font-size: 11px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 11px; color: #ffffff;\"\u003eWeight Per 1000ft Total (Lbs.) \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-top-width: 2pt; border-top-style: solid; border-top-color: black; background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003ca href=\"\/products\/mining-cable\/shd-gc-4-gauge-2\"\u003eSHD-GC - 4 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1.94\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2240\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/mining-cable\/shd-gc-4-gauge-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003ca href=\"\/products\/mining-cable\/shd-gc-2-gauge-2\"\u003eSHD-GC - 2 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.12\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2730\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/mining-cable\/shd-gc-2-gauge-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003ca href=\"\/products\/mining-cable\/shd-gc-1-0-2\"\u003eSHD-GC - 1\/0\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.32\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3380\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/mining-cable\/shd-gc-1-0-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003ca href=\"\/products\/mining-cable\/shd-gc-2-0-2\"\u003eSHD-GC - 2\/0\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.46\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4030\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/mining-cable\/shd-gc-2-0-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003ca href=\"\/products\/mining-cable\/shd-gc-4-0-2\"\u003eSHD-GC - 4\/0\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.75\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5440\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/mining-cable\/shd-gc-4-0-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003ca href=\"\/products\/mining-cable\/shd-gc-250mcm-2\"\u003eSHD-GC - 250MCM\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.89\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6280\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/mining-cable\/shd-gc-250mcm-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003ca href=\"\/products\/mining-cable\/shd-gc-350mcm-2\"\u003eSHD-GC - 350MCM\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3.20\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e8300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/mining-cable\/shd-gc-350mcm-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"font-size: 12px;\"\u003e\u003ca href=\"\/products\/mining-cable\/shd-gc-500mcm-2\"\u003eSHD-GC - 500MCM\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3.56\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e12000\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/mining-cable\/shd-gc-500mcm-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163607285823,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_a832a6ac-e0b9-4df6-b472-bde0a6dfa466.jpg?v=1571728266"},{"product_id":"shd-gc-4-gauge-3","title":"SHD-GC - 4 Gauge","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire No. Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16243.310400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7386204962879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_1_5f0ffdc6-d0a2-49aa-9f56-8707694bb3cb.jpg?v=1571729419"},{"product_id":"shd-gc-2-gauge-3","title":"SHD-GC - 2 Gauge","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire No. Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16243.310200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7386276003903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_1_84ab2ffe-469b-42c3-a908-bb39116ab38d.jpg?v=1571729419"},{"product_id":"shd-gc-1-4","title":"SHD-GC - 1\/0","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire No. Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16243.615100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7386294779967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_1_1d67525f-dd13-4e65-9b2b-fe857c37e522.jpg?v=1571729419"},{"product_id":"shd-gc-2-4","title":"SHD-GC - 2\/0","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire No. Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16252.201837\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7386316963903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_1_aad58b5a-2c97-48f5-9091-ec84e4269089.jpg?v=1571729419"},{"product_id":"shd-gc-4-4","title":"SHD-GC - 4\/0","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire No. Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7386358120511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_1_a8e08375-f753-40c3-a24f-bce36a47d899.jpg?v=1571729419"},{"product_id":"shd-gc-250mcm-2","title":"SHD-GC - 250MCM","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire No. Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16243.616000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7386377289791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_1_6c3d3d73-6534-41ed-9fa4-371db7a81eb3.jpg?v=1571729419"},{"product_id":"shd-gc-350mcm-2","title":"SHD-GC - 350MCM","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire No. Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16243.616200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7386388070463,"sku":"","price":50.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_1_523c82be-99ff-46db-b5ec-f348a7495385.jpg?v=1571729420"},{"product_id":"shd-gc-500mcm-2","title":"SHD-GC - 500MCM","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Jacket Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size (AWG):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire No. Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16243.616500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003eThis cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003eConductor is stranded annealed copper enveloped in a strand shield. Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. A single faced rubber filled tape is applied overlapped. Jacket is Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-66-524 (NEMA WC8).\u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7386414153791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-SHD-GC_1_d48add4e-3d70-461b-a584-378eb7160bf3.jpg?v=1571729420"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/type-shd-gc-8kv.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}