{"title":"Superior Essex Cable Interlock Armored 3mm Microarray Breakout OFCR\/OFCP Cable","description":"","products":[{"product_id":"superior-essex-cable-interlock-armored-3mm-microarray-breakout-ofcr-ofcp-cable-1","title":"Superior Essex Cable Interlock Armored 3mm Microarray Breakout OFCR\/OFCP Cable","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003elisting\u003c\/td\u003e\n\u003ctd\u003epackage\u003c\/td\u003e\n\u003ctd\u003esuperior essex cable \u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-interlock-armored-3-mm-microarray-breakout-ofcr-ofcp-cable-l3024\"\u003e24\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-interlock-armored-3-mm-microarray-breakout-ofcr-ofcp-cable-l3024\"\u003eL3024XPB1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-interlock-armored-3-mm-microarray-breakout-ofcr-ofcp-cable-l3024\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-36-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3036xpb1\"\u003e36\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-36-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3036xpb1\"\u003eL3036XPB1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-36-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3036xpb1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-48-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3048xp01\"\u003e48\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-48-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3048xp01\"\u003eL3048XP01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-48-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3048xp01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-72-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3072xp01\"\u003e72\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-72-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3072xp01\"\u003eL3072XP01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-72-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3072xp01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-96-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3096xp01\"\u003e96\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-96-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3096xp01\"\u003eL3096XP01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-96-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3096xp01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-144-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3144xp01\"\u003e144\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-144-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3144xp01\"\u003eL3144XP01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-144-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3144xp01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3024xpb1\"\u003e24\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3024xpb1\"\u003eL3024XPB1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3024xpb1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-36-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3036xpb1\"\u003e36\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-36-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3036xpb1\"\u003eL3036XPB1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-36-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3036xpb1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-48-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3048xp01\"\u003e48\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-48-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3048xp01\"\u003eL3048XP01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-48-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3048xp01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-72-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3072xp01\"\u003e72\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-72-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3072xp01\"\u003eL3072XP01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-72-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3072xp01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-96-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3096xp01\"\u003e96\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-96-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3096xp01\"\u003eL3096XP01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-96-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3096xp01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-144-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3144xp01\"\u003e144\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-144-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3144xp01\"\u003eL3144XP01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-144-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3144xp01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373361414207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3.jpg?v=1571729400"},{"product_id":"superior-essex-cable-144-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3144xp01-1","title":"Superior Essex Cable 144 Fiber Count Interlock Armored 3mm Microarray Breakout OFCR Cable L3144XP01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e144 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.08 (27.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e424 (632)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,340)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e16.2 (411)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e10.8 (274)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL3144xP01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373430915135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_26d42f3b-cd8b-4989-bc88-69c625b961af.jpg?v=1571729400"},{"product_id":"superior-essex-cable-96-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3096xp01-1","title":"Superior Essex Cable 96 Fiber Count Interlock Armored 3mm Microarray Breakout OFCR Cable L3096XP01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.95 (24.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e290 (432)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,340)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e14.3 (363)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e9.5 (242)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL3096xP01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373458899007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_f4d8edcd-6066-4f7f-91da-f608b96dfd11.jpg?v=1571729400"},{"product_id":"superior-essex-cable-72-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3072xp01-1","title":"Superior Essex Cable 72 Fiber Count Interlock Armored 3mm Microarray Breakout OFCR Cable L3072XP01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.87 (22.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e248 (370)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (670)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e50 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e13.0 (330)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e8.7 (220)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL3072xP01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373460930623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_03295944-7381-4d26-bf43-b1fd6d321a2c.jpg?v=1571729400"},{"product_id":"superior-essex-cable-48-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3048xp01-1","title":"Superior Essex Cable 48 Fiber Count Interlock Armored 3mm Microarray Breakout OFCR Cable L3048XP01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.77 (19.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e196 (293)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (670)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e50 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e11.6 (294)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e7.7 (196)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL3048xP01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373462306879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_ddc1b34c-4183-46d7-b076-60ac72b71e41.jpg?v=1571729400"},{"product_id":"superior-essex-cable-36-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3036xpb1-1","title":"Superior Essex Cable 36 Fiber Count Interlock Armored 3mm Microarray Breakout OFCR Cable L3036XPB1","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.77 (19.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e195 (291)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (670)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e50 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e11.6 (294)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e7.7 (196)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL3036XPB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373465485375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_c18b50eb-47d3-43ac-9314-ce12b6ce420a.jpg?v=1571729400"},{"product_id":"superior-essex-cable-24-fiber-count-interlock-armored-3mm-microarray-breakout-ofcr-cable-l3024xpb-1","title":"Superior Essex Cable 24 Fiber Count Interlock Armored 3mm Microarray Breakout OFCR Cable L3024XPB","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.77 (19.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e195 (291)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (670)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e50 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e11.6 (294)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e7.7 (196)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL3024XPB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373466009663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_4ce9cec1-9dc1-49f2-a049-b058383b038e.jpg?v=1571729400"},{"product_id":"superior-essex-cable-144-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3144xp01-1","title":"Superior Essex Cable 144 Fiber Count Interlock Armored 3mm Microarray Breakout OFCP Cable L3144XP01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"background-color: #ffffff;\"\u003eTechnical Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.08 (27.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e424 (632)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,340)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e16.2 (411)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e10.8 (274)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan style=\"white-space: pre-wrap; background-color: #ffffff; font-family: arial; font-size: 13px;\"\u003eSuperior Essex \u003c\/span\u003ePart Pumber¹\u003c\/td\u003e\n\u003ctd\u003eL4144xP01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373514244159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_dfd7f2e2-e78e-4aec-8e4d-d8a659132bbe.jpg?v=1571729400"},{"product_id":"superior-essex-cable-96-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3096xp01-1","title":"Superior Essex Cable 96 Fiber Count Interlock Armored 3mm Microarray Breakout OFCP Cable L3096XP01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.95 (24.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e290 (432)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,340)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e14.3 (363)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e9.5 (242)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL4096xP01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373514702911,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_d24460a2-2296-4bd7-9a1f-f3132cd3336d.jpg?v=1571729400"},{"product_id":"superior-essex-cable-36-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3036xpb1-1","title":"Superior Essex Cable 36 Fiber Count Interlock Armored 3mm Microarray Breakout OFCP Cable L3036XPB1","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e UL 1651\u003cbr\u003e CSA C22.2 No. 232\u003cbr\u003e UL 1666\u003cbr\u003e UL 910\u003cbr\u003e NFPA 262\u003cbr\u003e Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e ANSI\/ICEA S-83-596\u003cbr\u003e ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e UL, c(UL) Listed OFCR\u003cbr\u003e UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e UL Certified EPD\u003cbr\u003e HPD\u003cbr\u003e USGBC® Member\u003cbr\u003e RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e REACH-compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.77 (19.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e195 (291)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (670)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e50 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e11.6 (294)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e7.7 (196)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL3036XPB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373516374079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_ec0fc2c5-d5de-41c2-be8f-dbdba646f0bc.jpg?v=1571729400"},{"product_id":"superior-essex-cable-24-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3024xpb1-1","title":"Superior Essex Cable 24 Fiber Count Interlock Armored 3mm Microarray Breakout OFCP Cable L3024xPB1","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.77 (19.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e195 (291)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (670)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e50 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e11.6 (294)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e7.7 (196)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL3024XPB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373517291583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_b6e75a98-b88f-41e1-bc18-876619462f97.jpg?v=1571729400"},{"product_id":"superior-essex-cable-48-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3048xp01-1","title":"Superior Essex Cable 48 Fiber Count Interlock Armored 3mm Microarray Breakout OFCP Cable L3048XP01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.77 (19.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e196 (293)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (670)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e50 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e11.6 (294)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e7.7 (196)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL4048xP01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373518700607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_540f6744-df5b-4d93-8db5-aa67c2099387.jpg?v=1571729400"},{"product_id":"superior-essex-cable-72-fiber-count-interlock-armored-3mm-microarray-breakout-ofcp-cable-l3072xp01-1","title":"Superior Essex Cable 72 Fiber Count Interlock Armored 3mm Microarray Breakout OFCP Cable L3072XP01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlock Armored Microarray Breakout cable from Superior Essex is designed for high performance with robust mechanical protection. The premises loose tube design consists of 12-fiber 3 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. A RoHS-compliant flexible jacket protects the core while providing fire protection. Finally, the cable is interlock armored with either aluminum (standard) or steel and jacketed. The cable is available with TeraFlex® single mode or laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) or 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e • Health Product Declaration™ (HPD™)  • 12-fiber 3 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Interlock armor\u003cbr\u003e • Riser (OFCR) and plenum (OFCP) rated designs\u003cbr\u003e • Available with TeraFlex single mode and TeraFlex laseroptimized 50\/125 micron multimode bend-insensitive fiber types\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors Worry-free installation and performance Provides exceptional mechanical protection and crush resistance\u003cbr\u003e • UL listed cables meet NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e Subunit Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm simplex loose tube cable with twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003cbr\u003e 3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking\u003cbr\u003e \u003c\/strong\u003e Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element\u003c\/strong\u003e\u003cbr\u003e Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Cable\/Outer Jacket\u003c\/strong\u003e\u003cbr\u003e OFCR: Flame retardant (FR), PVC OFCP: FR, LSPVC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003cbr\u003e Flexible, heavy duty interlocking aluminum (standard) or steel tape helically applied over the inner cable core; further protection is provided by a flame retardant outer jacket\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • UL 1666\u003cbr\u003e • UL 910\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFCR\u003cbr\u003e • UL, c(UL) Listed OFCP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.87 (22.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e248 (370)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (670)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e50 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e13.0 (330)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e8.7 (220)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eReel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperior Essex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eL4072xP01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7373519388735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_43ad9b7d-615d-4d8a-97e2-af5a73edafed.jpg?v=1571729400"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/3_ed4558c5-33ee-4148-b6d4-f68cd1d15a68.jpg?v=1523951265","url":"https:\/\/nassauelectricalspot.com\/collections\/superior-essex-cable-interlock-armored-3mm-microarray-breakout-ofcr-ofcp-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}