{"title":"Superior Essex Cable 2 mm Microarray Breakout OFNP Cable","description":"","products":[{"product_id":"superior-essex-cable-2-mm-microarray-breakout-ofnp-cable-1","title":"Superior Essex Cable 2 mm Microarray Breakout OFNP Cable","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e \u003cbr\u003e • UL® Certified Environmental  \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™) \u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits \u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable \u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e \u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc) \u003cbr\u003e • Contributes toward 1 LEED point under the MRc \u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors \u003cbr\u003e • Worry-free installation and performance \u003cbr\u003e • Meets NEC requirements \u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e \u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e \u003cbr\u003e • UL 1651 \u003cbr\u003e • CSA C22.2 No. 232 \u003cbr\u003e • NFPA 262 \u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2 \u003cbr\u003e • ANSI\/ICEA S-83-596 \u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e \u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e \u003cbr\u003e • UL Certified EPD \u003cbr\u003e • HPD \u003cbr\u003e • USGBC® Member \u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant \u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e \u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds \u003cbr\u003e • Data centers \u003cbr\u003e • Trunk applications \u003cbr\u003e • High density installations \u003cbr\u003e • MTP\/MPO array connectors \u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003epackage\u003c\/td\u003e\n\u003ctd\u003esuperior essex cable \u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eBASE-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-024uxx-t991\"\u003e24\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-024uxx-t991\"\u003eF447-024UXX-T991\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superior-essex-cable-24-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-024uxx-t991\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-32-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-032uxx-t991\"\u003e32\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-32-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-032uxx-t991\"\u003eF447-032UXX-T991\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-32-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-032uxx-t991\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-48-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-048uxx-t991\"\u003e48\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-48-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-048uxx-t991\"\u003eF447-048UXX-T991\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-48-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-048uxx-t991\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-64-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-064uxx-t991\"\u003e64\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-64-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-064uxx-t991\"\u003eF447-064UXX-T991\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-64-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-064uxx-t991\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-96-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-096uxx-t991\"\u003e96\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-96-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-096uxx-t991\"\u003eF447-096UXX-T991\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-96-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-096uxx-t991\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eBASE-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-24-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4024zzb1\"\u003e24\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-24-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4024zzb1\"\u003eV4024ZZB1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-24-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4024zzb1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-36-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4036zzb1\"\u003e36\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-36-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4036zzb1\"\u003eV4036ZZB1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-36-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4036zzb1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-48-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4048zz01\"\u003e48\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-48-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4048zz01\"\u003eV4048ZZ01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-48-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4048zz01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-72-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4072zz01\"\u003e72\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-72-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4072zz01\"\u003eV4072ZZ01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-72-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4072zz01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-96-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4096zz01\"\u003e96\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-96-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4096zz01\"\u003eV4096ZZ01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-96-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4096zz01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-144-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4144zz01\"\u003e144\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12-around-1\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-144-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4144zz01\"\u003eV4144ZZ01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/loose-tube-fiber-cable\/superioressex-cable-144-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4144zz01\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7375907913791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7.jpg?v=1571729403"},{"product_id":"superior-essex-cable-24-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-024uxx-t991-1","title":"Superior Essex Cable 24 Fiber Count Base-8 2mm Microarray Breakout OFNP Cable F447-024UXX-T991","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.26 (6.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e29 (43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (710)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e45 (198)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.8 (98)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e2.6 (65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eF447-024UXX-T991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376076898367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_c0eef40a-3886-403f-8eb3-05f368e99c9b.jpg?v=1571729403"},{"product_id":"superior-essex-cable-32-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-032uxx-t991-1","title":"Superior Essex Cable 32 Fiber Count Base-8 2mm Microarray Breakout OFNP Cable F447-032UXX-T991","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.26 (6.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e29 (43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (710)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e45 (198)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.8 (98)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e2.6 (65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eF447-032Uxx-t991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376092135487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_38558323-580c-4927-a14e-c7d357337e8e.jpg?v=1571729403"},{"product_id":"superior-essex-cable-48-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-048uxx-t991-1","title":"Superior Essex Cable 48 Fiber Count Base-8 2mm Microarray Breakout OFNP Cable F447-048UXX-T991","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e6-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.31 (7.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e29 (43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,420)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (396)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.8 (98)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e2.6 (65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eF447-048UXX-T991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376097902655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_bac284dc-53dd-40af-acc0-348d1c01b7a1.jpg?v=1571729403"},{"product_id":"superior-essex-cable-64-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-064uxx-t991-1","title":"Superior Essex Cable 64 Fiber Count Base-8 2mm Microarray Breakout OFNP Cable F447-064UXX-T991","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e8-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.36 (9.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e44 (66)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,420)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (396)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e5.4 (138)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.6 (92)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eF447-064UXX-T991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376105144383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_1e4a6140-0f06-44fc-8908-c8b86a039d35.jpg?v=1571729403"},{"product_id":"superior-essex-cable-96-fiber-count-base-8-2mm-microarray-breakout-ofnp-cable-f447-096uxx-t991-1","title":"Superior Essex Cable 96 Fiber Count Base-8 2mm Microarray Breakout OFNP Cable F447-096UXX-T991","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e12-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.47 (12.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e101 (152)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,420)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (396)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e7.0 (180)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e4.7 (120)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eF447-096UXX-T991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376110420031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_d5130c01-f2b3-4690-b10c-2da7491b8911.jpg?v=1571729403"},{"product_id":"superior-essex-cable-24-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4024zzb1-1","title":"Superior Essex Cable 24 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4024ZZB1","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.26 (6.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e29 (43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (660) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e45 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.8 (98)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e2.6 (65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eV4024zzB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376192340031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_9339245e-1d41-4818-b44f-06d964f06ec1.jpg?v=1571729403"},{"product_id":"superior-essex-cable-48-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4048zz01-1","title":"Superior Essex Cable 48 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4048ZZ01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.26 (6.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e29 (43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (660)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e45 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.8 (98)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e2.6 (65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eV4048ZZ01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376196108351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_30423b45-0b99-4696-9120-a69304244f38.jpg?v=1571729403"},{"product_id":"superior-essex-cable-36-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4036zzb1-1","title":"Superior Essex Cable 36 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4036ZZB1","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e4-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.26 (6.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e29 (43)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e150 (660)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e45 (200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.8 (98)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e2.6 (65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eV4036ZZB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376205250623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_ac4e54cd-8765-49cb-8e61-2f88ede99dfc.jpg?v=1571729403"},{"product_id":"superior-essex-cable-72-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4072zz01-1","title":"Superior Essex Cable 72 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4072ZZ01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e6-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.31 (7.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e32 (47)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,334) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e4.7 (119)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.1 (79)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eV4072ZZ01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376209117247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_dd7cfdb7-a595-4ec0-a67d-90f68afaee4a.jpg?v=1571729403"},{"product_id":"superior-essex-cable-96-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4096zz01-1","title":"Superior Essex Cable 96 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4096ZZ01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e8-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.36 (9.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e44 (66) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,334)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e5.4 (138)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e3.6 (92)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eV4096ZZ01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376210657343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_a423c19d-e39f-479d-974f-a096fced1ce4.jpg?v=1571729403"},{"product_id":"superior-essex-cable-144-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4144zz01-1","title":"Superior Essex Cable 144 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4144ZZ01","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits, each of which contain twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/ MPO connector. The 2 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing plenum fire protection. The cable is available with TeraFlex® single mode, and TeraFlex laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • UL® Certified Environmental \u003cbr\u003e • Health Product Declaration\u0026amp;trade (HPD™)\u003cbr\u003e • 8 or 12-fiber 2 mm loose tube interconnect subunits\u003cbr\u003e • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e • Plenum (OFNP) rated design \u003cbr\u003e • Available with TeraFlex single mode, and TeraFlex laseroptimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e • Contributes toward 1 LEED point under the MRc\u003cbr\u003e • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e • Worry-free installation and performance\u003cbr\u003e • Meets NEC requirements\u003cbr\u003e • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e • UL 1651\u003cbr\u003e • CSA C22.2 No. 232\u003cbr\u003e • NFPA 262\u003cbr\u003e • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e • ANSI\/ICEA S-83-596\u003cbr\u003e • ANSI\/TIA-568-C.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e • UL, c(UL) Listed OFNP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e • UL Certified EPD\u003cbr\u003e • HPD\u003cbr\u003e • USGBC® Member\u003cbr\u003e • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e • REACH-compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e • Data centers\u003cbr\u003e • Trunk applications\u003cbr\u003e • High density installations\u003cbr\u003e • MTP\/MPO array connectors\u003cbr\u003e • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Count\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003e12-around-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Diameter in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.47 (12.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Weight lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e101 (152)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Install lbs (n)\u003c\/td\u003e\n\u003ctd\u003e300 (1,334)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Loading Long Term lbs (n)\u003c\/td\u003e\n\u003ctd\u003e90 (400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Install in (mm)\u003c\/td\u003e\n\u003ctd\u003e7.0 (180)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius Long Term in (mm)\u003c\/td\u003e\n\u003ctd\u003e4.7 (120)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eplywood reel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eOFNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n\u003ctd\u003eV4144ZZ01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7376212000831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/7_c02c7fa2-365e-4a4a-976f-83d63ab5ef4e.jpg?v=1571729403"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/7_e65184b9-4428-44ab-a2d1-22659285a8a4.jpg?v=1523975820","url":"https:\/\/nassauelectricalspot.com\/collections\/superior-essex-cable-2-mm-microarray-breakout-ofnp-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}