{"title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE","description":"","products":[{"product_id":"special-direct-burial-irrigation-control-cable","title":"Special Direct Burial Irrigation Control Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta charset=\"utf-8\"\u003eUntitled Document\n\u003cp\u003eThis cable is made using soft annealed tinned copper wire and is used in irrigation systems to offer connection for power to control circuits. It is insulated and jacketed for optimal performance in operations that require direct burial to underground without needing conduits. The tinned copper wire has excellent anti corrosion properties and this makes it ideal for use in areas that have high moisture such as residential and commercial irrigation schemes. The tinning process enhances the electrical conductivity of the wire while also allowing it to have easy workability such as soldering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e • Wiring valves to the controller of a sprinkler system\u003cbr\u003e • The tinned annealed copper wire has extensive use in wiring valves to connect them to the controller of a sprinkler. It is used for direct burials in outdoor environments where the need for conduits is not important.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e • Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C\u003cbr\u003e • The insulation is made of polyvinyl chloride or PVC which allows it to be resistant to fires, flames, heat, corrosion, water, acids, and sunlight.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacketing\u003c\/strong\u003e\u003cbr\u003e • Pressure extruded high density PE\u003cbr\u003e • The jacketing materials improves the performance of this tinned annealed copper cable when used in direct burial applications. The jacket is made using pressure extruded high density polyethylene material to reduce wear and tear, effects of abrasion, and enhance the installation and handling of the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e • Special direct burial\u003cbr\u003e • Irrigation control cable\u003cbr\u003e • Insulation: polyvinyl chloride\u003cbr\u003e • Jacket: impregnated polyethylene\u003cbr\u003e • Sizes: 14-12 AWG, 2 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • Soft annealed tinned copper\u003cbr\u003e • Applications up to 600 volts\u003cbr\u003e • Temperatures up to 75 degrees Celsius\u003c\/p\u003e\n\u003ctable width=\"100%\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center; font-size: 0.9em;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ffffff; height: 59px; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNo. of Conductors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eAction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-red\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e180115\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-red\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-white\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e180126\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-white\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-black\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e180127\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-black\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-orange\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e180114\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-orange\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-blue\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e180116\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-blue\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-yellow\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e180118\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-yellow\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-purple\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e1801181\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-purple\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-brown\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e1801182\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-brown\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-pink\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e1801151\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-pink\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-gray\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e1801183\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-gray\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-green\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.280'x.470'\u003c\/td\u003e\n\u003ctd\u003e180117\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-14-awg-green\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-red\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180161\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-red\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-black\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180160\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-black\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-orange\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180165\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-orange\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-blue\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180162\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-blue\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-yellow\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180163\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-yellow\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-purple\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180168\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-purple\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-brown\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180166\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-brown\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-gray\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180167\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"text-align: center; background-color: #f2f2f2; color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-gray\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-green\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\n\u003ctd\u003e180164\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/wire-accessories\/special-direct-burial-irrigation-control-cable-12-awg-green\" style=\"color: #0101ff;\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964386367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-black","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Black","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180160\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eBlack\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964419135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_e239953f-95b3-43f7-bf61-d9f837045835.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-blue","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Blue","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180162\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eBlue\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964451903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_820ac8df-a9a8-4ba7-87d9-af3687f98ef2.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-brown","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Brown","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180166\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eBrown\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964681279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_39c51099-8759-43e4-9529-f2a87f7ff93a.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-gray","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Gray","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180167\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eGray\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964746815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_9a9366ef-45a4-4f2d-9318-ef7269c58d37.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-green","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Green","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180164\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eGreen\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964779583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_49a7d660-be99-4f95-833a-6104ca88b217.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-orange","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Orange","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180165\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eOrange\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964877887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_1a24ee61-565a-4047-b060-345a54fed8e7.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-purple","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Purple","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180168\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003ePurple\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964910655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_f071ec19-8d3c-499b-8907-4da5fff9031b.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-red","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Red","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180161\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eRed\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165964943423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_f5ca487c-8a34-46af-a067-41137bcc0fa0.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-12-awg-yellow","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 12 AWG - Yellow","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180118\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eYellow\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.300\"x.505\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e105\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965041727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_1ae4ddc3-0118-4ed0-a244-45a20cc1036e.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-black","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Black","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180127\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eBlack\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965140031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_130c19d2-c8a8-4b29-a3f7-0a72d6f6d6d2.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-blue","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Blue","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180116\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eBlue\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965172799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_a742a1f2-7ca0-40e9-a7b9-ee1d53f42074.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-brown","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Brown","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1801182\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eBrown\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965336639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-sm.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-gray","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Gray","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1801183\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eGray\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965434943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_8ec37ecc-9590-4ffb-85f4-90bf0bc22c8f.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-green","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Green","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180117\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eGreen\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965467711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_fbb6f4d9-bcae-4da0-b75d-197ea64fa31f.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-orange","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Orange","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180114\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eOrange\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965566015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_f24bf15d-1563-4a77-8198-be2b356ace8a.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-pink","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Pink","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1801151\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003ePink\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965729855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_2ad5edb7-1662-4484-ad7e-2823a56904e3.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-purple","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Purple","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1801181\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003ePurple\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965959231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_a4ef3658-e155-4f09-9c97-1ddf4b258790.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-red","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Red","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180115\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eRed\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165965991999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_225b0309-7ada-4f03-954d-aa1c5257733b.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-white","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - White","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180126\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eWhite\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165966024767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_eb9e22a5-4c85-431e-8856-fc374fa31911.jpg?v=1571728769"},{"product_id":"special-direct-burial-irrigation-control-cable-14-awg-yellow","title":"SPECIAL DIRECT BURIAL IRRIGATION CONTROL CABLE - 14 AWG - Yellow","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e180118\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eAWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Color\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003eYellow\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIns. Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e60\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Walls (Mils)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e45\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eO.D.\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.280\"x.470\"\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight Lbs\/M\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cbr\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eSPECIAL DIRECT BURIAL\u003c\/li\u003e\r\n            \u003cli\u003eIRRIGATION CONTROL CABLE\u003c\/li\u003e\r\n            \u003cli\u003eINSULATION: POLYVINYL CHLORIDE\u003c\/li\u003e\r\n            \u003cli\u003eJACKET: IMPREGNATED POLYETHYLENE\u003c\/li\u003e\r\n            \u003cli\u003eSIZES: 14-12 AWG, 2 CONDUCTOR\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\r\n        This specification covers construction requirements for a 2-conductor control cable design consisting of tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as Type UF by UL or ETL or CSA.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft annealed tin coated solid copper conforming to ASTM B-33.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF\/TWU rated 75°C.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eCable Assembly:\u003c\/strong\u003e\u003cbr\u003e\r\n        Insulated conductors are laid parallel.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3\/64\" minimum jacket material to completely fill interstices between the two insulated conductors.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket Color:\u003c\/strong\u003e\u003cbr\u003e\r\n        Several\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Coding:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black, Red\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSurface Print:\u003c\/strong\u003e\u003cbr\u003e\r\n        \"PAIGE ELECTRIC P7072D SIZE 2C VOLTAGE1 DIRECT BURIAL SUNLIGHT RESISTANT FOR MAXI\/2-WIRE SYSTEMS\" RoHS.\r\n        Maxi is a trademarks of Rain Bird Corporation.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSPLICING RECOMMENDATIONS:\u003c\/strong\u003e\u003cbr\u003e\r\n        Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR\/Y-6, as manufactured by the 3M Company (Paige specification P7364D)\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003ePut-Ups:\u003c\/strong\u003e\u003cbr\u003e\r\n        2500' reels and odd lengths.\r\n        \u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eAdditional Notes:\u003c\/strong\u003e\u003cbr\u003e\r\n        The inner conductors are rated and labeled as 600V. The 48V rating on the print legend of the outer jacket is intentional, so as to prevent the use of this \"irrigation cable\" as \"building wire.\" The normal uses for this cable are for Rain Bird Maxi and 2-wire systems, for which the applied\/operating voltage is well below the 48V rating.\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165966123071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DIRECT-BURIAL-IRRIGATION-lg_1b34f469-3bb2-421a-af53-61c3a6b1363a.jpg?v=1571728769"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/118.jpg?v=1524023956","url":"https:\/\/nassauelectricalspot.com\/collections\/special-direct-burial-irrigation-control-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}