{"title":"Shielded Cable \/ Wire","description":"","products":[{"product_id":"shielded-cable-wire","title":"Shielded Wire \/ Cable","description":"\u003cdiv class=\"product-name\"\u003e\n\u003ch2\u003eSHIELDED CABLE \/ WIRE\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"grouping-select\"\u003e\n\u003cp\u003e\u003cstrong\u003eSelect gauge from drop-down menu for prices:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"grouping-container\"\u003e\n\u003cdiv class=\"drop-select\"\u003e\n\u003cdiv\u003eSHIELDED CABLE \/ WIRE\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eShield Wire is used in overhead ground wire, shielding transmission lines from lightning and other sources of electromagnetic interference and physical damage. It is used by power utility companies and wire and optical cable manufacturers.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eShield Wire is composed of hard-drawn steel conductor cores covered with a thick coating of pure aluminum that comprises at least 10% of the wire radius, and is concentric-lay-stranded. The aluminum is bonded to the steel core with a continuous ductile weld that won't separate, flake, or crack. Its steel core comprises the majority of the cable for excellent tensile strength equivalent to or greater than other types of shield wires. This allows for greater span lengths, reduced sagging, and increased durability under heavy loads during harsh weather conditions. Aluminum cladding provides corrosion resistance that is superior to that of galvanized steel, reducing maintenance and replacement costs and resulting in a longer-lasting cable. Aluminum-clad steel is also more conductive than galvanized steel and has excellent thermal stability when exposed to high temperatures. In addition, aluminum is much lighter than steel, so cladding significantly reduces the weight of the cable. This makes installation easier, places less strain on support structures, and lowers overall costs.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eProduct Highlights\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eConcentric-lay-stranded bare aluminum-clad hard-drawn steel conductors.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eExcellent tensile strength for greater span lengths, reduced sagging, and heavier loads.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eSuperior corrosion resistance for a longer lifespan.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eLightweight aluminum cladding for ease of installation, lower cost, and reduced strain on support structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eTechnical Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eB-416 Bare concentric-lay-stranded conductors constructed using bare, round, hard-drawn, aluminum covered steel wires that have 20.3% conductivity and are used for electrical purposes\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Nos\/AWG\u003cbr\u003eConductor\u003c\/td\u003e\n\u003ctd\u003eIndividual Wire\u003cbr\u003eDiameter (in.)\u003c\/td\u003e\n\u003ctd\u003eCross Section (mils.)\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-5\"\u003e37\/5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1819\u003c\/td\u003e\n\u003ctd\u003e1,225,000\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-5\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-6\"\u003e37\/6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1620\u003c\/td\u003e\n\u003ctd\u003e971,300\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-7\"\u003e37\/7\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1443\u003c\/td\u003e\n\u003ctd\u003e770,300\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-7\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-8\"\u003e37\/8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1285\u003c\/td\u003e\n\u003ctd\u003e610,900\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-9\"\u003e37\/9\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1144\u003c\/td\u003e\n\u003ctd\u003e484,400\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-9\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-10\"\u003e37\/10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1019\u003c\/td\u003e\n\u003ctd\u003e384,200\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-37-10\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-5\"\u003e19\/5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1819\u003c\/td\u003e\n\u003ctd\u003e628,900\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-5\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-6\"\u003e19\/6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1620\u003c\/td\u003e\n\u003ctd\u003e498,800\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-7\"\u003e19\/7\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1443\u003c\/td\u003e\n\u003ctd\u003e395,500\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-7\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-8\"\u003e19\/8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1285\u003c\/td\u003e\n\u003ctd\u003e313,700\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-9\"\u003e19\/9\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1144\u003c\/td\u003e\n\u003ctd\u003e248,800\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-9\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-10\"\u003e19\/10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1019\u003c\/td\u003e\n\u003ctd\u003e197,300\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-19-10\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-5\"\u003e7\/5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1819\u003c\/td\u003e\n\u003ctd\u003e231,700\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-5\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-6\"\u003e7\/6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1620\u003c\/td\u003e\n\u003ctd\u003e183,800\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-7\"\u003e7\/7\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1443\u003c\/td\u003e\n\u003ctd\u003e145,700\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-7\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-8\"\u003e7\/8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1285\u003c\/td\u003e\n\u003ctd\u003e115,600\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-9-1\"\u003e7\/9\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1144\u003c\/td\u003e\n\u003ctd\u003e91,650\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-9-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-9\"\u003e7\/10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1019\u003c\/td\u003e\n\u003ctd\u003e72,680\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-9\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-11\"\u003e7\/11\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.0907\u003c\/td\u003e\n\u003ctd\u003e57,590\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-11\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-12\"\u003e7\/12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.0808\u003c\/td\u003e\n\u003ctd\u003e45,710\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-7-12\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-5\"\u003e3\/5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1819\u003c\/td\u003e\n\u003ctd\u003e99,310\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-5\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-6\"\u003e3\/6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1620\u003c\/td\u003e\n\u003ctd\u003e78,750\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-7\"\u003e3\/7\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1443\u003c\/td\u003e\n\u003ctd\u003e62,450\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-7\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-8\"\u003e3\/8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1285\u003c\/td\u003e\n\u003ctd\u003e49,530\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-9\"\u003e3\/9\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1144\u003c\/td\u003e\n\u003ctd\u003e39,280\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-9\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-10\"\u003e3\/10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e.1019\u003c\/td\u003e\n\u003ctd\u003e31,150\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/aluminum\/shield-wire-3-10\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165077291071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_8fa83e29-1a48-420e-bfe3-f10c457309de.jpg?v=1571728619"},{"product_id":"shield-wire-19-10","title":"SHIELD WIRE - 19\/10","description":"\r\n    \r\n    \r\n    \r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e        \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\/10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1019\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.509\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e27,190\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e448.7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.2622\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e197,300\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.1549\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165948395583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_f651a7ea-1acb-4582-b023-c0c62b1d9225.jpg?v=1571728767"},{"product_id":"shield-wire-19-5","title":"SHIELD WIRE - 19\/5","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e       \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\/5\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1819\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.910\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e73,350\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1,430\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.08224\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e628,900\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.4940\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165948428351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_9a24cb1e-1601-45ca-a375-2f036e240138.jpg?v=1571728767"},{"product_id":"shield-wire-19-6","title":"SHIELD WIRE - 19\/6","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e       \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\/6\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1620\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.810\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e61,700\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1,134\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.1037\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e498,800\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.3917\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165948526655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_6a62c0bb-7764-4e77-8250-e8ee75789892.jpg?v=1571728767"},{"product_id":"shield-wire-19-7","title":"SHIELD WIRE - 19\/7","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e  -\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman'; white-space: pre;\" class=\"Apple-tab-span\"\u003e       \t\t    \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\/7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1443\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.721\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e51,730\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e889.5\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.1308\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e395,500\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.3107\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165948559423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_52357555-ae1a-4c28-93e3-f0535adf86fa.jpg?v=1571728767"},{"product_id":"shield-wire-19-8","title":"SHIELD WIRE - 19\/8","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e        \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\/8\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1285\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.642\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e43,240\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e713.5\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.1649\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e313,700\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.2464\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165948592191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_a21e2968-27eb-4283-acdb-e80ec4376f32.jpg?v=1571728767"},{"product_id":"shield-wire-19-9","title":"SHIELD WIRE - 19\/9","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e        \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\/9\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1144\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.572\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e34,290\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e565.8\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.2079\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e248,800\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.1954\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165948821567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_6f9103b7-0ad3-4efd-ba44-57a04ba291a7.jpg?v=1571728767"},{"product_id":"shield-wire-3-10","title":"SHIELD WIRE 3\/10","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e3\/10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1019\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4,532\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e70.43\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.651\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e31,150\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.02446\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165948985407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_7883f47a-49dd-40ec-b553-9fd151bc305e.jpg?v=1571728767"},{"product_id":"shield-wire-3-5","title":"SHIELD WIRE 3\/5","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e3\/5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1819\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.392\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e12,230\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e224.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.5177\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e99,310\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.07800\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949018175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_4dd74979-f440-4d32-a698-45c1f3a7a6b5.jpg?v=1571728767"},{"product_id":"shield-wire-3-6","title":"SHIELD WIRE 3\/6","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e3\/6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1620\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.349\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e10,280\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e178.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.6528\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e78,750\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.06185\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949116479,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_4c0e0783-97b7-4950-8f2a-6d434b65c607.jpg?v=1571728767"},{"product_id":"shield-wire-3-7","title":"SHIELD WIRE 3\/7","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e3\/7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1443\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.311\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e8,621\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e141.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.8232\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e62,450\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.04905\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949182015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_c7a674d9-4de2-4bc2-9c8d-b5bf4a09bba1.jpg?v=1571728767"},{"product_id":"shield-wire-3-8","title":"SHIELD WIRE 3\/8","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e3\/8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1285\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.277\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7,206\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e112.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.038\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e49,530\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.03890\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949214783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_6d03f3e6-4b3d-4f4d-bb75-f8f90dd6cca1.jpg?v=1571728767"},{"product_id":"shield-wire-3-9","title":"SHIELD WIRE 3\/9","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e3\/9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1144\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.247\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e5,715\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e88.81\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.309\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e39,280\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.03085\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949313087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_98ee836d-a987-419e-b012-abc2e693f69c.jpg?v=1571728767"},{"product_id":"shield-wire-37-10","title":"SHIELD WIRE - 37\/10","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e       \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\/10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1019\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.713\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e52,950\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e879\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.1354\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e384,200\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.3017\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949345855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_c0bcf7fc-9d24-46a8-b102-7023aead0edd.jpg?v=1571728767"},{"product_id":"shield-wire-37-5","title":"SHIELD WIRE - 37\/5","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"font-weight: 700; line-height: 23.8px;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e       \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\/5\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1819\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e1.27\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e142,800\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2,802\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.04247\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1,225,000\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.9619\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949444159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_311000f4-f786-4410-914e-350ff2509fa6.jpg?v=1571728767"},{"product_id":"shield-wire-37-6","title":"SHIELD WIRE - 37\/6","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e       \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\/6\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1620\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e1.13\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e120,200\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2,222\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.05356\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e971,300\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.7629\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949542463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_4d2fb87c-922a-4710-8bf6-b0cf44d4ad26.jpg?v=1571728768"},{"product_id":"shield-wire-37-7","title":"SHIELD WIRE - 37\/7","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e       \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\/7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1443\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e1.01\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e100,700\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1,762\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.06754\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e770,300\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.6050\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949640767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_35cfd55f-4263-4b45-9d44-0bf753df7691.jpg?v=1571728768"},{"product_id":"shield-wire-37-8","title":"SHIELD WIRE - 37\/8","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e       \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\/8\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1285\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.899\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e84,200\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1,398\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.08516\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e610,900\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.4798\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949673535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_fd825767-42fb-41c0-a310-1a6bab853593.jpg?v=1571728768"},{"product_id":"shield-wire-37-9","title":"SHIELD WIRE - 37\/9","description":"\r\n    \r\n    \r\n    \r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eShield Wire\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eProduct Description:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis product consists of concentric-lay-stranded conductors.  The conductors are made of aluminum-clad steel wires.  The shield wire is a ground conductor that is used as a reference point for the voltage of an overhead transmission line.  The wire acts as a shield to protect primary lines from being affected by lightning, EMI, precipitation, and corrosive gasses.  A primarily steel structure makes this product extremely strong and durable.  The steel is clad with aluminum to resist corrosion. \u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003eThis conductor is commonly used for overhead shielding of transmission lines in areas where high corrosion is likely, such as coastal regions or at sea. This cable is commonly employed to shield communication lines as well.  The metal layer wraps around the primary conductors to protect against outside electromagnetic interference.\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e \u003c\/span\u003eIn accordance with specifications set forth by the American Society for Testing and Materials:\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eThis product meets with ASTM standard B416 for aluminum-clad steel hard drawn wire.\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003e\u003cbr style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003e\r\n        \u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-weight: 700;\"\u003eConstruction:\u003c\/span\u003e\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eConductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 0.75in; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px; text-indent: -0.25in;\"\u003e-\u003cspan style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e       \u003c\/span\u003eConductors are made using high strength steel wires.  Steel wires are aluminum-clad to improve resistance to corrosion.\u003c\/p\u003e\r\n        \u003cul style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px 32px; padding: 0px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e\r\n            \u003cli style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent;\"\u003eStranding\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; margin: 0px 0px 18px; font-family: latoregular, sans-serif; color: #475054; font-size: 17px; line-height: 23.8px;\"\u003e            -           Concentrically stranded.\u003c\/p\u003e\r\n        \u003cbr\u003e\r\n        \u003ctrstyle\u003e\r\n        \u003cbr\u003e\r\n        \u003cbr\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\/9\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e.1144\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\r\n                    \u003c\/td\u003e\r\n                    \u003ctd\u003e.801\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e66,700\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1,108\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.1074\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e484,400\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.3805\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cbr\u003e\r\n        \u003c\/p\u003e\r\n        \u003cul\u003e\r\n        \u003c\/ul\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949706303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_88a05af0-315c-4d01-be7c-f2a7c34a7a2e.jpg?v=1571728768"},{"product_id":"shield-wire-7-10","title":"SHIELD WIRE 7\/10","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\/10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1019\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.306\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e10,020\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e164.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.7088\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e72,680\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.05708\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949804607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_7245b137-ad68-4386-9f28-31a0216741ac.jpg?v=1571728768"},{"product_id":"shield-wire-7-11","title":"SHIELD WIRE 7\/11","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\/11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.0907\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.272\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7,945\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e130.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.8938\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e57,590\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.04523\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949837375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_c2ccb095-0ca6-4c75-99a6-825d1aebc3bf.jpg?v=1571728768"},{"product_id":"shield-wire-7-12","title":"SHIELD WIRE 7\/12","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\/12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.0808\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.242\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e6,301\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e103.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.127\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e45,710\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.03590\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949870143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_633dfc3c-a963-4625-b630-ae031a4c3509.jpg?v=1571728768"},{"product_id":"shield-wire-7-5","title":"SHIELD WIRE 7\/5","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\/5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1819\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.546\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e27,030\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e524.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.2264\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e231,700\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.1820\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165949968447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_a4d322e0-6869-4248-853a-2db4075f5546.jpg?v=1571728768"},{"product_id":"shield-wire-7-6","title":"SHIELD WIRE 7\/6","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\/6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1620\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.486\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e22,730\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e416.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.2803\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e183,800\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.1443\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165950001215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_fca75193-aaea-418e-a255-94d080008374.jpg?v=1571728768"},{"product_id":"shield-wire-7-7","title":"SHIELD WIRE 7\/7","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\/7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1443\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.433\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e19,060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e330.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.3535\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e145,700\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.1145\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165950033983,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_8161a962-8271-4011-8871-4d417aba88aa.jpg?v=1571728768"},{"product_id":"shield-wire-7-8","title":"SHIELD WIRE 7\/8","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\/8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1285\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.385\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15,930\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e261.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.4458\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e115,600\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.09077\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165950132287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_460f330a-f036-45dc-b6b8-a7591e8c3235.jpg?v=1571728768"},{"product_id":"shield-wire-7-9","title":"SHIELD WIRE 7\/9","description":"\n    \n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize Nos\/AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\/9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eIndividual Wire Diameter (in.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e.1144\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong\u003eStranded Diameter (in.)\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e.343\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eBreaking Load (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e12,630\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eWeight (lb.\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e207.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eResistance at 20°C (Ω\/1,000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.5621\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (C mils.)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e91,650\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCross Section (in²)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.07198\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eSHIELD WIRE\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003cbr\u003e\n        Concentric-lay-stranded conductors made of aluminum-clad steel wires.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        Commonly used for overhead shield wire in high corrosion areas such as industrial, seashore, and desert environments.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecification Data:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eASTM B-416\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7165950165055,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SHIELD-WIRE-lg_236811d7-a737-4b62-aff6-f9b47da71361.jpg?v=1571728768"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/shielded-cable-wire.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}