{"title":"Service Wire Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable","description":"","products":[{"product_id":"service-wire-1-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp1-3","title":"Service Wire 1 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP1\/3","description":"Service Wire 1 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP1\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 1 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP1\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP1\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e1.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e1,332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP1\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165796646975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg.jpg?v=1571728718"},{"product_id":"service-wire-1-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp1-03","title":"Service Wire 1\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP1\/03","description":"Service Wire 1\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP1\/03\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 1\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP1\/03. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP1\/03\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e1.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e1,677\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP1\/03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165802053695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_58e9afbb-362b-400e-92eb-99082defbc41.jpg?v=1571728719"},{"product_id":"service-wire-10-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp10-3","title":"Service Wire 10 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP10\/3","description":"Service Wire 10 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP10\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 10 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP10\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP10\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e40†\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP10\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165812572223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_15f8864f-c237-445d-bc43-76447a3dabc3.jpg?v=1571728721"},{"product_id":"service-wire-12-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp12-3","title":"Service Wire 12 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP12\/3","description":"Service Wire 12 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP12\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 12 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP12\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP12\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e30†\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP12\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165823123519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_9e80c7ce-b248-4025-85a8-817fc85d2cb1.jpg?v=1571728723"},{"product_id":"service-wire-14-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp14-3","title":"Service Wire 14 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP14\/3","description":"Service Wire 14 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP14\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 14 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP14\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP14\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e0.57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e274\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e25†\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP14\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165830463551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_76c2b904-71bd-40ca-b12e-2c87f4b66f37.jpg?v=1571728725"},{"product_id":"service-wire-2-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp2-3","title":"Service Wire 2 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP2\/3","description":"Service Wire 2 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP2\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 2 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP2\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP2\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e0.98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e1,103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP2\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165842358335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_584ec37e-011e-4317-8386-5eea5283ac25.jpg?v=1571728727"},{"product_id":"service-wire-2-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp2-03","title":"Service Wire 2\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP2\/03","description":"Service Wire 2\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP2\/03\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 2\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP2\/03. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP2\/03\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e1.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e1,991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP2\/03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165848485951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_60a8dd3a-25de-4974-bba3-7d7be88831fe.jpg?v=1571728728"},{"product_id":"service-wire-250-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp250-3","title":"Service Wire 250 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP250\/3","description":"Service Wire 250 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP250\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 250 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP250\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP250\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e1.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e3,562\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP250\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165854089279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_b776bdcb-c9d3-4fca-9fa5-a31dd305eb57.jpg?v=1571728740"},{"product_id":"service-wire-3-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp3-3","title":"Service Wire 3 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP3\/3","description":"Service Wire 3 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP3\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 3 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP3\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP3\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e0.92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e889\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP3\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165862445119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_4fec86dc-a9c4-4f27-bcba-3d0c870d4ea1.jpg?v=1571728741"},{"product_id":"service-wire-3-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp3-03","title":"Service Wire 3\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP3\/03","description":"Service Wire 3\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP3\/03\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 3\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP3\/03. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP3\/03\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e1.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e2,513\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP3\/03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165865656383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_ad649b6c-ac15-45df-a24d-030315a9b209.jpg?v=1571728742"},{"product_id":"service-wire-350-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp350-3","title":"Service Wire 350 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP350\/3","description":"Service Wire 350 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP350\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 350 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP350\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP350\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e1.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e4,876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP350\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165875585087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_6774eddb-a70f-4196-b7b6-e4ec84af9aa1.jpg?v=1571728744"},{"product_id":"service-wire-4-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp4-3","title":"Service Wire 4 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP4\/3","description":"Service Wire 4 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP4\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 4 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP4\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP4\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e0.87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP4\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165885087807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_0a5de63b-9661-4d16-8309-c2305cf1d61a.jpg?v=1571728745"},{"product_id":"service-wire-4-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp4-03","title":"Service Wire 4\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP4\/03","description":"Service Wire 4\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP4\/03\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 4\/0 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP4\/03. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP4\/03\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e1.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e3,004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP4\/03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165889019967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_fcafb59e-c364-4dba-be62-92f39b01db64.jpg?v=1571728747"},{"product_id":"service-wire-500-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp500-3","title":"Service Wire 500 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP500\/3","description":"Service Wire 500 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP500\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 500 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP500\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP500\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e2.23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e6,638\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP500\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165898719295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_d5bcaef1-8c24-47d0-990e-3a2006a8a3ed.jpg?v=1571728748"},{"product_id":"service-wire-6-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp6-3","title":"Service Wire 6 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP6\/3","description":"Service Wire 6 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP6\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 6 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP6\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP6\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e0.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e539\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP6\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165903962175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_c622ebc3-3779-4379-87ae-f58336c5cd67.jpg?v=1571728749"},{"product_id":"service-wire-600-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp600-3","title":"Service Wire 600 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP600\/3","description":"Service Wire 600 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP600\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 600 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP600\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP600\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e2.49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e8,018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP600\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165911760959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_8b19941a-bca4-4f35-9c1f-686ca697662a.jpg?v=1571728750"},{"product_id":"service-wire-750-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp750-3","title":"Service Wire 750 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP750\/3","description":"Service Wire 750 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP750\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 750 MCM Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP750\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP750\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e2.70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e9,846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP750\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165916807231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_2fef886a-7129-4bd0-9196-668a09d657a6.jpg?v=1571728751"},{"product_id":"service-wire-8-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp8-3","title":"Service Wire 8 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP8\/3","description":"Service Wire 8 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP8\/3\u003cmeta name=\"Description\" content=\"Browse our Selection of Service Wire 8 AWG Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable ASDTCP8\/3. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Tray Cable, Tray Cable Price, Tray Cable quote, Shielded Cable, Shielded Cable Price, Copper Cable, Copper Cable Price, Copper Cable Quote, ASDTCP8\/3\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esize awg or kcmil\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estrand(no.)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrounding conductors(awg)\u003c\/td\u003e\n\u003ctd\u003e3-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC Jacket Thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. diameter overall(inch)\u003c\/td\u003e\n\u003ctd\u003e0.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. net weight(lb\/1000')\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity*(30°c ambient) 90°c wet\/dry\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eASDTCP8\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165918576703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_fa844e74-c952-4d31-933c-0e6899c1b595.jpg?v=1571728752"},{"product_id":"service-wire-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable","title":"Service Wire Tray Cable ASD\/VFD XHHW-2\/PVC Shielded Patented 600 Volt Copper Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall black PVC jacket. Jacket available in colors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in ASD\/VFD applications.\u003cbr\u003e Suitable for use in hazardous locations:\u003cbr\u003e • Class I - Div 2\u003cbr\u003e • Class II - Div 2\u003cbr\u003e • Class III - Div 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e • UL 1277\u003cbr\u003e • CSA C22.2 #230 TC\u003cbr\u003e • ICEA S-95-658\/NEMA WC-70\u003cbr\u003e • Exposed Runs Rated (TC-ER) (#4 AWG and larger)\u003cbr\u003e Flame Rated:\u003cbr\u003e • IEEE 383 (70,000 BTU)\u003cbr\u003e • ICEA T-29-520 (210,000 BTU) (1\/0 AWG and larger)\u003cbr\u003e • IEEE 1202\/CSA FT-4\u003cbr\u003e • Two-hour Firewall\u003cbr\u003e • Temperature Rated at 90°C Wet\/Dry Sunlight and Oil Resistant II Jacket Direct Burial\u003cbr\u003e • Code: Method 4\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize AWG\/kcmil\u003c\/td\u003e\n\u003ctd\u003estrand (no.)\u003c\/td\u003e\n\u003ctd\u003eampacity* (30°c ambient)\u003cbr\u003e 90ºc wet\/dry\u003c\/td\u003e\n\u003ctd\u003eservice wire part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-14-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp14-3\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e25†\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-14-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp14-3\"\u003eASDTCP14\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-14-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp14-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-12-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp12-3\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e30†\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-12-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp12-3\"\u003eASDTCP12\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-12-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp12-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-10-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp10-3\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e40†\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-10-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp10-3\"\u003eASDTCP10\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-10-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp10-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-8-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp8-3\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-8-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp8-3\"\u003eASDTCP8\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-8-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp8-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-6-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp6-3\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-6-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp6-3\"\u003eASDTCP6\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-6-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp6-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-4-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp4-3\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-4-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp4-3\"\u003eASDTCP4\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-4-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp4-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-3-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp3-3\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-3-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp3-3\"\u003eASDTCP3\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-3-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp3-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-2-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp2-3\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-2-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp2-3\"\u003eASDTCP2\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-2-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp2-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-1-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp1-3\"\u003e1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-1-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp1-3\"\u003eASDTCP1\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-1-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp1-3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-1-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp1-0\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-1-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp1-0\"\u003eASDTCP1\/03\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-1-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp1-0\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-2-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp2-0\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-2-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp2-0\"\u003eASDTCP2\/03\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-2-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp2-0\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-3-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp3-0\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-3-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp3-0\"\u003eASDTCP3\/03\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-3-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp3-0\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-4-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp4-0\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-4-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp4-0\"\u003eASDTCP4\/03\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-4-0-awg-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp4-0\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-250-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp250\"\u003e250\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-250-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp250\"\u003eASDTCP250\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-250-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp250\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-350-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp350\"\u003e350\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-350-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp350\"\u003eASDTCP350\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-350-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp350\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-500-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp500\"\u003e500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-500-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp500\"\u003eASDTCP500\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-500-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp500\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-600-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp600\"\u003e600\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-600-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp600\"\u003eASDTCP600\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-600-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp600\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-750-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp750\"\u003e750\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e535\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-750-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp750\"\u003eASDTCP750\/3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/tray-cable-vntc-vfd-festoon\/vfd-cable\/service-wire-750-mcm-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable-asdtcp750\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Service Wire","offers":[{"title":"Default Title","offer_id":7165938925631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/ASDVFD_20XHHW-2_20PVC_20Shielded_20Patented-lg_e3e59710-cb24-4fd5-8079-1a81548c90f4.jpg?v=1571728755"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/service-wire-tray-cable-asd-vfd-xhhw-2-pvc-shielded-patented-600-volt-copper-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}