{"title":"Prysmian Cable 5kV EPR URD 100% Aluminum Medium Voltage Utility Cables","description":"","products":[{"product_id":"prysmian-cable-250-mcm-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qju010a","title":"Prysmian Cable 250 MCM 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJU010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 250 MCM 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJU010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJU010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJU010A, 250 MCM USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e250 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.561\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.87\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1104\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e288\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e179\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e179\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e386\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e179\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e179\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJU010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186380554303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_d4785651-2b33-4fea-bc8c-e0fb60d7b231.jpg?v=1571729017"},{"product_id":"prysmian-cable-250-mcm-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qju000a","title":"Prysmian Cable 250 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJU000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 250 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJU000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJU000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJU000A, 250 MCM USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e250 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e13-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.561\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.87\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e721\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e284\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e37\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e360\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e377\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e356\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJU000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186380685375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_dd8ab14c-cc3e-4e1a-a569-c2b5c46549b0.jpg?v=1571729017"},{"product_id":"prysmian-cable-3-0-awg-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjs010a","title":"Prysmian Cable 3\/0 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJS010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 3\/0 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJS010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 3\/0 AWG USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJS010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJS010A, 3\/0 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e3\/0 solid al\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.458\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.76\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e759\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e224\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e275\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e275\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e307\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e275\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e275\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJS010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186400706623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_92b1a5c3-d227-49f0-9ae8-deabc256a519.jpg?v=1571729023"},{"product_id":"prysmian-cable-3-0-awg-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjs000a","title":"Prysmian Cable 3\/0 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJS000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 3\/0 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJS000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 3\/0 AWG USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJS000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJS000A, 3\/0 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e3\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e9-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.458\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.76\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.00\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e545\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e227\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e139\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e522\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e313\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e152\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e89\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e516\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJS000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186400772159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_b3b9f6c4-18a7-4989-9c36-361756c077a4.jpg?v=1571729023"},{"product_id":"prysmian-cable-350-mcm-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjv010a","title":"Prysmian Cable 350 MCM 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJV010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 350 MCM 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJV010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJV010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJV010A, 350 MCM USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e350 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.664\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.97\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1394\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e342\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e454\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJV010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186415517759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_a29a387c-3f67-4584-b5e8-5abda670dc53.jpg?v=1571729047"},{"product_id":"prysmian-cable-350-mcm-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjv000a","title":"Prysmian Cable 350 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJV000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 350 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJV000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJV000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJV000A, 350 MCM USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e350 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e18-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.664\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.97\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e919\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e343\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e260\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e433\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e88\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e258\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJV000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186415550527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_7fed1343-9b1c-4aeb-9f1b-8e5f99a78189.jpg?v=1571729047"},{"product_id":"prysmian-cable-4-0-awg-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjt010a","title":"Prysmian Cable 4\/0 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJT010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJT010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJT010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJT010A, 4\/0 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e13-#10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.515\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e941\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e258\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e216\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e348\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJT010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186434359359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_dd17bc78-4194-4405-8b99-ff32d7b9d1d5.jpg?v=1571729055"},{"product_id":"prysmian-cable-4-0-awg-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjt000a","title":"Prysmian Cable 4\/0 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJT000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJT000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJT000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJT000A, 4\/0 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e11-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.515\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e634\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e258\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e38\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e425\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e350\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e126\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJT000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186434621503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_993db243-2447-4a78-be51-fea42ddbbf58.jpg?v=1571729055"},{"product_id":"prysmian-cable-500-mcm-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjw000a","title":"Prysmian Cable 500 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJW000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 500 MCM USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJW000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 500 MCM USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJW000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJW000A, 500 MCM USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e500 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.794\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1256\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e416\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e34\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e183\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e489\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e72\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e182\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJW000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186474860607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_d769de00-acc7-489f-b760-dca9ad75db99.jpg?v=1571729073"},{"product_id":"prysmian-cable-5kv-epr-urd-100-aluminum-medium-voltage-utility-cables","title":"Prysmian Cable 5kV EPR URD 100% Aluminum Medium Voltage Utility Cables","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Black LLDPE jacket with no stripes \u003cbr\u003e • Black PVC jacket sleeved over separator tape \u003cbr\u003e • No Jacket \u003cbr\u003e • Multiplex cables \u003cbr\u003e • Tinned round and flat strap neutrals \u003cbr\u003e • Strandseal® \u003cbr\u003e • Compact stranded conductors \u003cbr\u003e • UL MV-90 Rating if required \u003cbr\u003e • 46kV \u003cbr\u003e • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e • Conduit in Air \u003cbr\u003e • Underground Duct \u003cbr\u003e • Wet Locations \u003cbr\u003e • With Messenger \u003cbr\u003e • Direct Buried \u003cbr\u003e • Isolated in Air \u003cbr\u003e • Dry Locations \u003cbr\u003e • Utility Primary \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e • AEIC- AEIC CS8 \u003cbr\u003e • ICEA- ICEA S-94-649 \u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003econductor\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003einsulation\u003cbr\u003e thickness\u003cbr\u003e (mils)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003econcentric\u003cbr\u003e neutral\u003c\/td\u003e\n\u003ctd\u003econd.\u003cbr\u003e dia.(in)\u003c\/td\u003e\n\u003ctd\u003eins.\u003cbr\u003e dia.\u003cbr\u003e (in)\u003c\/td\u003e\n\u003ctd\u003eins.\u003cbr\u003e shield\u003cbr\u003e diameter (in)\u003c\/td\u003e\n\u003ctd\u003ejacket\u003cbr\u003e dia.(in)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003ecable\u003cbr\u003e weight\u003cbr\u003e (lbs\/kft)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003emin.\u003cbr\u003e bending\u003cbr\u003e radius (in)\u003c\/td\u003e\n\u003ctd\u003e†\u003cbr\u003e amp.\u003cbr\u003e (amps)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e resistance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e reactance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e†\u003cbr\u003e amp.\u003cbr\u003e (amps)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e resistance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e reactance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eprysmian Cable Part\u003cbr\u003e number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003e(a)\u003c\/td\u003e\n\u003ctd\u003e(b)\u003c\/td\u003e\n\u003ctd\u003e(c)\u003c\/td\u003e\n\u003ctd\u003e(d)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e105°c in duct\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e105°c direct buried\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"16\" style=\"text-align: center;\"\u003e5kv 100% aluminum single phase - full neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-solid-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003e2 solid al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e10-#14\u003c\/td\u003e\n\u003ctd\u003e0.258\u003c\/td\u003e\n\u003ctd\u003e0.49\u003c\/td\u003e\n\u003ctd\u003e0.56\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003ctd\u003e376\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e694\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e182\u003c\/td\u003e\n\u003ctd\u003e694\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-solid-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003eQJL010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-c\"\u003e2 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e10-#14\u003c\/td\u003e\n\u003ctd\u003e0.284\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003ctd\u003e0.58\u003c\/td\u003e\n\u003ctd\u003e0.82\u003c\/td\u003e\n\u003ctd\u003e392\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003ctd\u003e701\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003ctd\u003e701\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-c\"\u003eQJM010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-solid-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003e1 solid al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e13-#14\u003c\/td\u003e\n\u003ctd\u003e0.289\u003c\/td\u003e\n\u003ctd\u003e0.52\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003ctd\u003e0.83\u003c\/td\u003e\n\u003ctd\u003e439\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e149\u003c\/td\u003e\n\u003ctd\u003e542\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003ctd\u003e542\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-solid-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003eQJN010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-c\"\u003e1 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e13-#14\u003c\/td\u003e\n\u003ctd\u003e0.324\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003ctd\u003e0.86\u003c\/td\u003e\n\u003ctd\u003e457\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e547\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e547\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-c\"\u003eQJO010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-0-solid-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utili\"\u003e1\/0 solid al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e16-#14\u003c\/td\u003e\n\u003ctd\u003e0.325\u003c\/td\u003e\n\u003ctd\u003e0.56\u003c\/td\u003e\n\u003ctd\u003e0.63\u003c\/td\u003e\n\u003ctd\u003e0.86\u003c\/td\u003e\n\u003ctd\u003e508\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e169\u003c\/td\u003e\n\u003ctd\u003e435\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e236\u003c\/td\u003e\n\u003ctd\u003e435\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-0-solid-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utili\"\u003eQJP010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-0-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003e1\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e16-#14\u003c\/td\u003e\n\u003ctd\u003e0.364\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003ctd\u003e0.66\u003c\/td\u003e\n\u003ctd\u003e0.90\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e171\u003c\/td\u003e\n\u003ctd\u003e440\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003ctd\u003e440\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-0-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003eQJQ010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-0-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003e2\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e13-#12\u003c\/td\u003e\n\u003ctd\u003e0.408\u003c\/td\u003e\n\u003ctd\u003e0.64\u003c\/td\u003e\n\u003ctd\u003e0.71\u003c\/td\u003e\n\u003ctd\u003e0.98\u003c\/td\u003e\n\u003ctd\u003e649\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e197\u003c\/td\u003e\n\u003ctd\u003e343\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e271\u003c\/td\u003e\n\u003ctd\u003e343\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-0-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003eQJR010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-3-0-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003e3\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e16-#12\u003c\/td\u003e\n\u003ctd\u003e0.458\u003c\/td\u003e\n\u003ctd\u003e0.69\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003ctd\u003e1.03\u003c\/td\u003e\n\u003ctd\u003e759\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e224\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e307\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-3-0-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003eQJS010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-4-0-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003e4\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e13-#10\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e0.82\u003c\/td\u003e\n\u003ctd\u003e1.13\u003c\/td\u003e\n\u003ctd\u003e941\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e348\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-4-0-awg-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003eQJT010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-250-mcm-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003e250 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e16-#10\u003c\/td\u003e\n\u003ctd\u003e0.561\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003ctd\u003e0.87\u003c\/td\u003e\n\u003ctd\u003e1.18\u003c\/td\u003e\n\u003ctd\u003e1104\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003ctd\u003e179\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e386\u003c\/td\u003e\n\u003ctd\u003e179\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-250-mcm-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003eQJU010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-350-mcm-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003e350 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e16-#9\u003c\/td\u003e\n\u003ctd\u003e0.664\u003c\/td\u003e\n\u003ctd\u003e0.90\u003c\/td\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003ctd\u003e1.31\u003c\/td\u003e\n\u003ctd\u003e1394\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e454\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-350-mcm-usa-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility\"\u003eQJV010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"16\" style=\"text-align: center;\"\u003e5kv 100% aluminum three phase \u003cspan style=\"text-align: center;\"\u003e- one third neutral\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-solid-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e2 solid al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e6-#14\u003c\/td\u003e\n\u003ctd\u003e0.258\u003c\/td\u003e\n\u003ctd\u003e0.49\u003c\/td\u003e\n\u003ctd\u003e0.56\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003ctd\u003e344\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e355\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-solid-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJL000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utili\"\u003e2 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e6-#14\u003c\/td\u003e\n\u003ctd\u003e0.284\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003ctd\u003e0.58\u003c\/td\u003e\n\u003ctd\u003e0.82\u003c\/td\u003e\n\u003ctd\u003e346\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003ctd\u003e351\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e361\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utili\"\u003eQJM000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-solid-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e1 solid al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e6-#14\u003c\/td\u003e\n\u003ctd\u003e0.289\u003c\/td\u003e\n\u003ctd\u003e0.52\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003ctd\u003e0.83\u003c\/td\u003e\n\u003ctd\u003e358\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e152\u003c\/td\u003e\n\u003ctd\u003e273\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e218\u003c\/td\u003e\n\u003ctd\u003e284\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-solid-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJN000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utili\"\u003e1 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e6-#14\u003c\/td\u003e\n\u003ctd\u003e0.324\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003ctd\u003e0.86\u003c\/td\u003e\n\u003ctd\u003e376\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e153\u003c\/td\u003e\n\u003ctd\u003e279\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e218\u003c\/td\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utili\"\u003eQJO000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-0-solid-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-u\"\u003e1\/0 solid al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e6-#14\u003c\/td\u003e\n\u003ctd\u003e0.325\u003c\/td\u003e\n\u003ctd\u003e0.56\u003c\/td\u003e\n\u003ctd\u003e0.63\u003c\/td\u003e\n\u003ctd\u003e0.86\u003c\/td\u003e\n\u003ctd\u003e392\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003ctd\u003e217\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003ctd\u003e247\u003c\/td\u003e\n\u003ctd\u003e227\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-0-solid-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-u\"\u003eQJP000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-0-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e1\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e6-#14\u003c\/td\u003e\n\u003ctd\u003e0.364\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003ctd\u003e0.66\u003c\/td\u003e\n\u003ctd\u003e0.90\u003c\/td\u003e\n\u003ctd\u003e413\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003ctd\u003e222\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e247\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1-0-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJQ000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-0-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e2\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e7-#14\u003c\/td\u003e\n\u003ctd\u003e0.408\u003c\/td\u003e\n\u003ctd\u003e0.64\u003c\/td\u003e\n\u003ctd\u003e0.71\u003c\/td\u003e\n\u003ctd\u003e0.95\u003c\/td\u003e\n\u003ctd\u003e469\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e279\u003c\/td\u003e\n\u003ctd\u003e187\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-2-0-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJR000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-3-0-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e3\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e9-#14\u003c\/td\u003e\n\u003ctd\u003e0.458\u003c\/td\u003e\n\u003ctd\u003e0.69\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e227\u003c\/td\u003e\n\u003ctd\u003e139\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003ctd\u003e152\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-3-0-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJS000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-4-0-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e4\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e11-#14\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e0.82\u003c\/td\u003e\n\u003ctd\u003e1.05\u003c\/td\u003e\n\u003ctd\u003e634\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003ctd\u003e111\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e126\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-4-0-awg-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJT000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-250-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e250 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e13-#14\u003c\/td\u003e\n\u003ctd\u003e0.561\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003ctd\u003e0.87\u003c\/td\u003e\n\u003ctd\u003e1.11\u003c\/td\u003e\n\u003ctd\u003e721\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e284\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e377\u003c\/td\u003e\n\u003ctd\u003e111\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-250-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJU000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-350-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e350 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e18-#14\u003c\/td\u003e\n\u003ctd\u003e0.664\u003c\/td\u003e\n\u003ctd\u003e0.90\u003c\/td\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003ctd\u003e1.21\u003c\/td\u003e\n\u003ctd\u003e919\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e343\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e433\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-350-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJV000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-500-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e500 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e16-#12\u003c\/td\u003e\n\u003ctd\u003e0.794\u003c\/td\u003e\n\u003ctd\u003e1.03\u003c\/td\u003e\n\u003ctd\u003e1.12\u003c\/td\u003e\n\u003ctd\u003e1.39\u003c\/td\u003e\n\u003ctd\u003e1256\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e416\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e489\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-500-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJW000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-750-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003e750 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e24-#12\u003c\/td\u003e\n\u003ctd\u003e0.974\u003c\/td\u003e\n\u003ctd\u003e1.22\u003c\/td\u003e\n\u003ctd\u003e1.31\u003c\/td\u003e\n\u003ctd\u003e1.58\u003c\/td\u003e\n\u003ctd\u003e1735\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e508\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e552\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-750-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-uti\"\u003eQJX000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1000-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-ut\"\u003e1000 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e20-#10\u003c\/td\u003e\n\u003ctd\u003e1.124\u003c\/td\u003e\n\u003ctd\u003e1.37\u003c\/td\u003e\n\u003ctd\u003e1.46\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003ctd\u003e2305\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e574\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e591\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/prysmian-cable-1000-mcm-usa-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-ut\"\u003eQJY000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\u003c!--\n.listing-a .item-details table td {\n            padding: 10px 1px;\n--\u003e\u003c\/style\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186478530623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_6764f27f-22cd-423d-baa9-dd6e3dcda783.jpg?v=1571729075"},{"product_id":"prysmian-cable-750-mcm-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjx000a","title":"Prysmian Cable 750 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJX000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 750 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJX000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 750 MCM USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJX000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJX000A, 750 MCM USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e750 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e24-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.974\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.58\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1735\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e508\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e36\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e32\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e122\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e552\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e122\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJX000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186487345215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_88d37b6e-8a42-4c2f-af1b-aedb52fe9200.jpg?v=1571729079"},{"product_id":"prysmian-cable-1-awg-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjo010a","title":"Prysmian Cable 1 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJO010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJO010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1 AWG USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJO010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJO010A, 1 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e13-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.324\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.86\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e457\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e150\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e547\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e547\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e210\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e547\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e547\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJO010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187726630975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_1508a4ed-c1b5-4b9b-8ab7-77f69c0f4b49.jpg?v=1571729308"},{"product_id":"prysmian-cable-1-awg-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjo000a","title":"Prysmian Cable 1 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJO000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJO000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1 AWG USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJO000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJO000A, 1 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e6-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.324\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.86\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e376\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e153\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e279\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e851\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e218\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e288\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e838\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJO000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187726729279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_dfee6a97-2e03-4287-86a0-5f8809746e1b.jpg?v=1571729308"},{"product_id":"prysmian-cable-1-solid-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjn010a","title":"Prysmian Cable 1 Solid 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJN010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1 Solid 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJN010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1 Solid USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJN010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJN010A, 1 Solid USA 5kV  Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1 solid al\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e13-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.289\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e439\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e149\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e542\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e542\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e208\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e542\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e542\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJN010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187750486079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_7c827755-cbbf-4049-aa36-25c5a049e07b.jpg?v=1571729312"},{"product_id":"prysmian-cable-1-solid-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjn000a","title":"Prysmian Cable 1 Solid 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJN000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1 Solid 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJN000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1 Solid USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJN000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJN000A, 1 Solid USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1 SOLID AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e6-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.289\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e358\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e152\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e273\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e845\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e218\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e284\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e100\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e831\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJN000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187750518847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_e6bd216a-f46e-4fde-854f-7e98e483affa.jpg?v=1571729312"},{"product_id":"prysmian-cable-1-0-awg-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjq010a","title":"Prysmian Cable 1\/0 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJQ010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJQ010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJQ010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJQ010A, 1\/0 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.364\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.66\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e530\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e171\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e440\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e440\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e238\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e440\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e440\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJQ010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187771785279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_81fa7f4d-c5d5-47e4-abe9-1322a801dee8.jpg?v=1571729317"},{"product_id":"prysmian-cable-1-0-awg-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjq000a","title":"Prysmian Cable 1\/0 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJQ000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJQ000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJQ000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJQ000A, 1\/0 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e6-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.364\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.66\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e413\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e174\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e222\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e42\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e795\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e247\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e231\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e103\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e784\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJQ000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187771818047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_ff6c0763-05a9-45f2-83bf-847295bbb98d.jpg?v=1571729317"},{"product_id":"prysmian-cable-1-0-solid-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjp010a","title":"Prysmian Cable 1\/0 Solid 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJP010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 Solid 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJP010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 Solid USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJP010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJP010A, 1\/0 Solid USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 SOLID AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.325\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.63\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.86\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e508\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e169\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e435\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e435\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e236\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e435\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e435\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJP010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187805863999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_40baa04c-6cce-48bb-b870-b1f8a6572afa.jpg?v=1571729336"},{"product_id":"prysmian-cable-1-0-solid-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjp000a","title":"Prysmian Cable 1\/0 Solid 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJP000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 Solid USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJP000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 Solid USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJP000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJP000A, 1\/0 Solid USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 SOLID AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e6-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.325\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.63\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.86\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e392\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e174\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e217\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e43\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e789\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e247\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e227\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJP000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187806191679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_aa906455-3702-4dac-984a-5efa1654b032.jpg?v=1571729336"},{"product_id":"prysmian-cable-1000-mcm-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjy000a","title":"Prysmian Cable 1000 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJY000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1000 MCM 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJY000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1000 MCM USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJY000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJY000A, 1000 MCM USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1000 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e20-#10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e1.124\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.37\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.46\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e2305\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e574\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e29\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e591\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e46\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJY000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187822706751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_844f2385-1711-45cf-acfe-d54e4adf5f45.jpg?v=1571729339"},{"product_id":"prysmian-cable-2-awg-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjm010a","title":"Prysmian Cable 2 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJM010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJM010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2 AWG USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJM010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJM010A, 2 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e2 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e10-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.284\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.51\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.58\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e392\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e131\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e701\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e701\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e183\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e701\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e701\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJM010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187845447743,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_fc26f5bc-0530-4ae2-b654-2155b7a6f813.jpg?v=1571729342"},{"product_id":"prysmian-cable-2-awg-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjm000a","title":"Prysmian Cable 2 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJM000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2 AWG USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJM000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2 AWG USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJM000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJM000A, 2 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e2 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e6-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.284\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.51\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.58\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e346\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e134\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e351\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e46\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e922\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e192\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e361\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e102\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e909\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJM000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187845480511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_a732140d-7f7b-4f69-8711-8f48f414eac6.jpg?v=1571729342"},{"product_id":"prysmian-cable-2-solid-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjl010a","title":"Prysmian Cable 2 Solid 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJL010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2 Solid 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJL010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2 Solid USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJL010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJL010A, 2 Solid USA 5Kv Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e2 solid al\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e10-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.258\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.49\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e376\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e130\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e694\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e694\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e182\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e694\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e694\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJL010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187863568447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_ec562a7f-a379-4df3-9d2c-a19ec7e80d79.jpg?v=1571729345"},{"product_id":"prysmian-cable-2-solid-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjl000a","title":"Prysmian Cable 2 Solid 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJL000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2 Solid 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJL000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2 Solid USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJL000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJL000A, 2 Solid USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e2 solid al\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e6-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.258\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.49\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e330\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e134\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e344\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e46\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e915\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e192\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e355\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e103\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e900\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJL000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187863633983,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_2c63e99f-193c-4e0c-9bde-390cb1dec9bd.jpg?v=1571729345"},{"product_id":"prysmian-cable-2-0-awg-5kv-epr-urd-100-aluminum-single-phase-full-neutral-medium-voltage-utility-cables-qjr010a","title":"Prysmian Cable 2\/0 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJR010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJR010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG USA 5kV EPR URD 100% Aluminum Single Phase Full Neutral Medium Voltage Utility Cables QJR010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJR010A, 2\/0 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e13-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.408\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.64\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.71\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e649\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e197\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e343\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e343\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e271\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e343\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e343\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJR010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187886178367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_2f6f23eb-c8d6-4da7-8310-3020e88f9dd1.jpg?v=1571729361"},{"product_id":"prysmian-cable-2-0-awg-5kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qjr000a","title":"Prysmian Cable 2\/0 AWG 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJR000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJR000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG USA 5kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QJR000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Price, Prysmian USA 5kV Quote, Aluminum Medium Voltage Utility Cable, Aluminum Medium Voltage Utility Price, Aluminum Medium Voltage Utility Cable Quote, 5kV EPR URD 100% Cable Price, 5kV EPR URD 100% Quote, 5kV EPR URD 100% Cable, 5kV EPR URD 100% Cable, QJR000A, 2\/0 AWG USA 5kV Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e7-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.408\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.64\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.71\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e0.95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e469\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e199\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e176\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e668\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e279\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e187\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e659\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQJR000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187886211135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_e593e2d4-3a9b-4f70-9a52-930a6967ff03.jpg?v=1571729361"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/prysmian-cable-5kv-epr-urd-100-aluminum-medium-voltage-utility-cables.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}