{"title":"Prysmian Cable 35kV EPR URD 133% Copper Medium Voltage Utility Cables","description":"","products":[{"product_id":"prysmian-cable-250-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qrc000a","title":"Prysmian Cable 250 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRC000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 250 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRC000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRC000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRC000A, 250 MCM 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e250 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e21-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.561\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.46\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e2167\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e375\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e47\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e218\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e28\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e443\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e76\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e79\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e216\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e28\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRC000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186379309119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_5e60e307-0566-4471-8e6d-ee188b18effd.jpg?v=1571729016"},{"product_id":"prysmian-cable-3-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cables-qra010a","title":"Prysmian Cable 3\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QRA010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 3\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QRA010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 3\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QRA010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRA010A, 3\/0 AWG 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e3\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.458\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e2111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e306\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e386\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRA010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186398937151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_4ab3bb2c-3309-4ace-8409-633991633bc0.jpg?v=1571729023"},{"product_id":"prysmian-cable-3-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qra000a","title":"Prysmian Cable 3\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRA000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 3\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRA000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 3\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRA000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRA000A, 3\/0 AWG 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e3\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e14-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.458\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.74\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1717\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e302\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e86\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e49\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e326\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e376\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e99\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e88\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRA000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186399035455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_7ca3b238-0f65-4de0-af5c-3117234c7238.jpg?v=1571729023"},{"product_id":"prysmian-cable-350-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qrd000a","title":"Prysmian Cable 350 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRD000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 350 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRD000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRD000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRD000A, 350 MCM 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e350 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e18-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.664\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.57\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e2.02\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e2757\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e445\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e159\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e501\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e64\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e71\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e158\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRD000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186412798015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_6d73cbdc-1a39-4306-9417-036ee4ae6238.jpg?v=1571729027"},{"product_id":"prysmian-cable-35kv-epr-urd-133-copper-medium-voltage-utility-cables","title":"Prysmian Cable 35kV EPR URD 133% Copper Medium Voltage Utility Cables","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Black LLDPE jacket with no stripes \u003cbr\u003e • Black PVC jacket sleeved over separator tape \u003cbr\u003e • No Jacket \u003cbr\u003e • Multiplex cables \u003cbr\u003e • Tinned round and flat strap neutrals \u003cbr\u003e • Strandseal® \u003cbr\u003e • Compact stranded conductors \u003cbr\u003e • UL MV-90 Rating if required \u003cbr\u003e • 46kV \u003cbr\u003e • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation: \u003c\/strong\u003e\u003cbr\u003e • Conduit in Air \u003cbr\u003e • Underground Duct \u003cbr\u003e • Wet Locations \u003cbr\u003e • With Messenger \u003cbr\u003e • Direct Buried \u003cbr\u003e • Isolated in Air \u003cbr\u003e • Dry Locations \u003cbr\u003e • Utility Primary \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e\u003cbr\u003e • AEIC- AEIC CS8 \u003cbr\u003e • ICEA- ICEA S-94-649 \u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003econductor\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003einsulation\u003cbr\u003e thickness\u003cbr\u003e (mils)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003econcentric\u003cbr\u003e neutral\u003c\/td\u003e\n\u003ctd\u003econd.\u003cbr\u003e dia.(in)\u003c\/td\u003e\n\u003ctd\u003eins.\u003cbr\u003e dia.\u003cbr\u003e (in)\u003c\/td\u003e\n\u003ctd\u003eins.\u003cbr\u003e shield\u003cbr\u003e diameter (in)\u003c\/td\u003e\n\u003ctd\u003ejacket\u003cbr\u003e dia.(in)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003ecable\u003cbr\u003e weight\u003cbr\u003e (lbs\/kft)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003emin.\u003cbr\u003e bending\u003cbr\u003e radius (in)\u003c\/td\u003e\n\u003ctd\u003e†\u003cbr\u003e amp.\u003cbr\u003e (amps)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e resistance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e reactance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e†\u003cbr\u003e amp.\u003cbr\u003e (amps)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e resistance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e reactance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eprysmian Cable\u003cbr\u003e part\u003cbr\u003e number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003e(a)\u003c\/td\u003e\n\u003ctd\u003e(b)\u003c\/td\u003e\n\u003ctd\u003e(c)\u003c\/td\u003e\n\u003ctd\u003e(d)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e105°c in duct\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e105°c direct buried\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"16\" style=\"text-align: center;\"\u003e35kv 133% copper single phase - full neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1-0-solid-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-ca\"\u003e1\/0 solid cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e16-#12\u003c\/td\u003e\n\u003ctd\u003e0.325\u003c\/td\u003e\n\u003ctd\u003e1.22\u003c\/td\u003e\n\u003ctd\u003e1.31\u003c\/td\u003e\n\u003ctd\u003e1.58\u003c\/td\u003e\n\u003ctd\u003e1498\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e298\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1-0-solid-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-ca\"\u003eQR7010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cabl\"\u003e1\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e16-#12\u003c\/td\u003e\n\u003ctd\u003e0.364\u003c\/td\u003e\n\u003ctd\u003e1.26\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003ctd\u003e1.62\u003c\/td\u003e\n\u003ctd\u003e1542\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e236\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cabl\"\u003eQR8010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-2-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cabl\"\u003e2\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e13-#10\u003c\/td\u003e\n\u003ctd\u003e0.408\u003c\/td\u003e\n\u003ctd\u003e1.30\u003c\/td\u003e\n\u003ctd\u003e1.39\u003c\/td\u003e\n\u003ctd\u003e1.77\u003c\/td\u003e\n\u003ctd\u003e1865\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-2-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cabl\"\u003eQR9010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-3-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cabl\"\u003e3\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e16-#10\u003c\/td\u003e\n\u003ctd\u003e0.458\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003ctd\u003e1.82\u003c\/td\u003e\n\u003ctd\u003e2111\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e306\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e386\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-3-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cabl\"\u003eQRA010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-4-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cabl\"\u003e4\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e16-#9\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003ctd\u003e1.41\u003c\/td\u003e\n\u003ctd\u003e1.50\u003c\/td\u003e\n\u003ctd\u003e1.90\u003c\/td\u003e\n\u003ctd\u003e2457\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e348\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e434\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-4-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cabl\"\u003eQRB010A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"16\" style=\"text-align: center;\"\u003e35kv 133% copper three phase - one third neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1-0-solid-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utilit\"\u003e1\/0 solid cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e9-#14\u003c\/td\u003e\n\u003ctd\u003e0.325\u003c\/td\u003e\n\u003ctd\u003e1.22\u003c\/td\u003e\n\u003ctd\u003e1.31\u003c\/td\u003e\n\u003ctd\u003e1.55\u003c\/td\u003e\n\u003ctd\u003e1272\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003ctd\u003e132\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e299\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1-0-solid-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utilit\"\u003eQR7000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003e1\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e9-#14\u003c\/td\u003e\n\u003ctd\u003e0.364\u003c\/td\u003e\n\u003ctd\u003e1.26\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003ctd\u003e1.59\u003c\/td\u003e\n\u003ctd\u003e1314\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003eQR8000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-2-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003e2\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e11-#14\u003c\/td\u003e\n\u003ctd\u003e0.408\u003c\/td\u003e\n\u003ctd\u003e1.30\u003c\/td\u003e\n\u003ctd\u003e1.39\u003c\/td\u003e\n\u003ctd\u003e1.63\u003c\/td\u003e\n\u003ctd\u003e1463\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e267\u003c\/td\u003e\n\u003ctd\u003e107\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e337\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-2-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003eQR9000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-3-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003e3\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e14-#14\u003c\/td\u003e\n\u003ctd\u003e0.458\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003ctd\u003e1.74\u003c\/td\u003e\n\u003ctd\u003e1717\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e302\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003ctd\u003e376\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-3-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003eQRA000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-4-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003e4\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e18-#14\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003ctd\u003e1.41\u003c\/td\u003e\n\u003ctd\u003e1.50\u003c\/td\u003e\n\u003ctd\u003e1.80\u003c\/td\u003e\n\u003ctd\u003e1954\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-4-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003eQRB000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-250-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003e250 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e21-#14\u003c\/td\u003e\n\u003ctd\u003e0.561\u003c\/td\u003e\n\u003ctd\u003e1.46\u003c\/td\u003e\n\u003ctd\u003e1.55\u003c\/td\u003e\n\u003ctd\u003e1.85\u003c\/td\u003e\n\u003ctd\u003e2167\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e443\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-250-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003eQRC000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-350-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003e350 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e18-#12\u003c\/td\u003e\n\u003ctd\u003e0.664\u003c\/td\u003e\n\u003ctd\u003e1.57\u003c\/td\u003e\n\u003ctd\u003e1.69\u003c\/td\u003e\n\u003ctd\u003e2.02\u003c\/td\u003e\n\u003ctd\u003e2757\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e501\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-350-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003eQRD000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-500-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003e500 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e17-#10\u003c\/td\u003e\n\u003ctd\u003e0.794\u003c\/td\u003e\n\u003ctd\u003e1.70\u003c\/td\u003e\n\u003ctd\u003e1.82\u003c\/td\u003e\n\u003ctd\u003e2.19\u003c\/td\u003e\n\u003ctd\u003e3580\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e557\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-500-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003eQRE000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-750-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003e750 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e20-#9\u003c\/td\u003e\n\u003ctd\u003e0.974\u003c\/td\u003e\n\u003ctd\u003e1.88\u003c\/td\u003e\n\u003ctd\u003e2.00\u003c\/td\u003e\n\u003ctd\u003e2.40\u003c\/td\u003e\n\u003ctd\u003e4843\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e616\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e624\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-750-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-\"\u003eQRF000A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1000-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility\"\u003e1000 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e21-#8\u003c\/td\u003e\n\u003ctd\u003e1.124\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003ctd\u003e2.15\u003c\/td\u003e\n\u003ctd\u003e2.58\u003c\/td\u003e\n\u003ctd\u003e6073\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e671\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e682\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-power-cable-5kv-46kv\/underground-residential-5-46-kv-epr-cable\/prysmian-cable-1000-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility\"\u003eQRG0001A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\u003c!--\n.listing-a .item-details table td {\n            padding: 10px 1px;\n--\u003e\u003c\/style\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186420695103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_278274c1-b9f3-4bb3-a0fc-0f784e74ef01.jpg?v=1571729049"},{"product_id":"prysmian-cable-4-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cables-qrb010a","title":"Prysmian Cable 4\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QRB010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QRB010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QRB010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRB010A, 4\/0 AWG 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.515\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.41\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e2457\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e348\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e434\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRB010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186432327743,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_8fa45de0-b71c-494a-aa9c-dffe1ae1978d.jpg?v=1571729054"},{"product_id":"prysmian-cable-4-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qrb000a","title":"Prysmian Cable 4\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRB000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRB000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRB000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRB000A, 4\/0 AWG 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e18-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.515\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.41\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1954\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e342\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e47\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e255\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e29\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e415\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e251\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e29\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRB000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186432360511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_b0392fe3-53f7-4cba-ab1d-0311be8d6a84.jpg?v=1571729054"},{"product_id":"prysmian-cable-500-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qre000a","title":"Prysmian Cable 500 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRE000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 500 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRE000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 500 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRE000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRE000A, 500 MCM 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e500 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e17-#10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.794\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.70\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e2.19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e3580\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e525\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e42\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e108\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e557\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e54\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e107\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRE000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186472665151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_cc99924d-ea47-4191-90a5-c1da44ae8ad0.jpg?v=1571729073"},{"product_id":"prysmian-cable-750-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qrf000a","title":"Prysmian Cable 750 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRF000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 750 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRF000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 750 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRF000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRF000A, 750 MCM 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e750 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e20-#9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.974\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.88\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e2.00\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e2.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e4843\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e616\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e74\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e624\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e48\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e74\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRF000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186486263871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_93a2cf9e-db03-4e2a-b2c9-17235e524962.jpg?v=1571729079"},{"product_id":"prysmian-cable-1-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cables-qr8010a","title":"Prysmian Cable 1\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR8010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR8010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR8010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QR8010A, 1\/0 AWG 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.364\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1542\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e236\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e34\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e34\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQR8010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187767066687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_c9371f71-073e-4ed9-960d-f89351c49839.jpg?v=1571729316"},{"product_id":"prysmian-cable-1-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qr8000a","title":"Prysmian Cable 1\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR8000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR8000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR8000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QR8000A, 1\/0 AWG 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e9-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.364\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1314\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e235\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e134\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e53\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e507\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e34\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e144\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e496\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e34\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQR8000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187767099455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_dd20c176-5290-4de7-baa7-78173bdc34f7.jpg?v=1571729316"},{"product_id":"prysmian-cable-1-0-solid-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cables-qr7010a","title":"Prysmian Cable 1\/0 Solid 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR7010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 Solid 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR7010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 Solid 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR7010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QR7010A, 1\/0 Solid 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 SOLID CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e16-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.325\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.58\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1498\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e234\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e268\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e36\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e268\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e36\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e298\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e268\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e36\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e268\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e36\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQR7010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187801997375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_a724a18a-3152-47a9-addb-e0d0fa6c6109.jpg?v=1571729336"},{"product_id":"prysmian-cable-1-0-solid-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qr7000a","title":"Prysmian Cable 1\/0 Solid 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR7000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 Solid 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR7000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 Solid 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR7000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QR7000A, 1\/0 Solid 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 SOLID CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e9-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.325\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1272\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e235\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e132\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e54\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e504\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e299\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e142\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e97\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e492\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQR7000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187802030143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_a7f20079-c58e-48a3-862b-3e8289688b7e.jpg?v=1571729336"},{"product_id":"prysmian-cable-1000-mcm-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qrg0001a","title":"Prysmian Cable 1000 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRG0001A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1000 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRG0001A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1000 MCM 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QRG0001A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QRG0001A, 1000 MCM 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1000 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e21-#8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e1.124\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e2.03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e2.15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e2.58\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e6073\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e671\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e36\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e682\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQRG0001A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187821723711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_81e04c38-f08d-436c-8dce-87e68632f1ed.jpg?v=1571729339"},{"product_id":"prysmian-cable-2-0-awg-35kv-epr-urd-133-copper-single-phase-full-neutral-medium-voltage-utility-cables-qr9010a","title":"Prysmian Cable 2\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR9010A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR9010A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG 35kV EPR URD 133% Copper Single Phase Full Neutral Medium Voltage Utility Cables QR9010A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QR9010A, 2\/0 AWG 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e13-#10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.408\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.77\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1865\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e212\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e212\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e341\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e212\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e212\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQR9010A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187883556927,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_ba4409f6-172c-4067-9c9d-ee4b97c6dc8e.jpg?v=1571729361"},{"product_id":"prysmian-cable-2-0-awg-35kv-epr-urd-133-copper-three-phase-one-third-neutral-medium-voltage-utility-cables-qr9000a","title":"Prysmian Cable 2\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR9000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR9000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG 35kV EPR URD 133% Copper Three Phase One Third Neutral Medium Voltage Utility Cables QR9000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 35kV EPR URD 133% Copper Medium Quote, 35kV EPR URD 133% Copper Medium Cable, 35kV EPR URD 133% Copper Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QR9000A, 2\/0 AWG 35kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e11-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.408\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e1.30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e1.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.63\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e1463\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e267\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e107\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e51\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e413\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e32\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e337\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e119\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e404\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e32\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQR9000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187883655231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_f2e1e3eb-a53b-4288-b049-40bae8aaf99a.jpg?v=1571729361"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/prysmian-cable-35kv-epr-urd-133-copper-medium-voltage-utility-cables.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}