{"title":"Prysmian Cable 35kV 100% EPR Doubleseal Copper Medium Voltage Utility Cables","description":"","products":[{"product_id":"prysmian-cable-250-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qqc020a","title":"Prysmian Cable 250 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQC020A","description":"Prysmian Cable 250 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQC020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQC020A. Click for a free quote. 250 MCM.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQC030A, 250 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQC020A, QQC020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e250 MCM cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e21-#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1980\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQC020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186377998399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_425932b0-df80-418d-8838-5777cea8302a.jpg?v=1571729004"},{"product_id":"prysmian-cable-3-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utility-cables-qqa030a","title":"Prysmian Cable 3\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQA030A","description":"Prysmian Cable 3\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQA030A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 3\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQA030A. Click for a free quote. 3\/0 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQA030A, 3\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQA030A, QQA030A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e3\/0 awg cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e16-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e386\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQA030A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186395103295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_15ca4de0-cd69-4caa-b783-77f19941c4cf.jpg?v=1571729022"},{"product_id":"prysmian-cable-3-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qqa020a","title":"Prysmian Cable 3\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQA020A","description":"Prysmian Cable 3\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQA020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 3\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQA020A. Click for a free quote. 3\/0 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQA030A, 3\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQA020A, QQA020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e3\/0 awg cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e14-#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1476\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQA020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186396545087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_3a5bd0fe-c604-4338-95e0-396bc8f9a8d0.jpg?v=1571729022"},{"product_id":"prysmian-cable-350-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qqd020a","title":"Prysmian Cable 350 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQD020A","description":"Prysmian Cable 350 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQD020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQD020A. Click for a free quote. 350 MCM.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQD030A, 350 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQD020A, QQD020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e350 MCM cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e18-#12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e2520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQD020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186410963007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_2cb39938-9234-48f8-ac25-5c67c695a9ca.jpg?v=1571729027"},{"product_id":"prysmian-cable-35kv-100-epr-doubleseal-copper-medium-voltage-utility-cables","title":"Prysmian Cable 35kV 100% EPR Doubleseal Copper Medium Voltage Utility Cables","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003econductor\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003einsulation\u003cbr\u003e thickness\u003cbr\u003e (mils)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003econcentric\u003cbr\u003e neutral\u003c\/td\u003e\n\u003ctd\u003econd.\u003cbr\u003e dia.(in)\u003c\/td\u003e\n\u003ctd\u003eins.\u003cbr\u003e dia.\u003cbr\u003e (in)\u003c\/td\u003e\n\u003ctd\u003eins.\u003cbr\u003e shield\u003cbr\u003e diameter (in)\u003c\/td\u003e\n\u003ctd\u003ejacket\u003cbr\u003e dia.(in)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003ecable\u003cbr\u003e weight\u003cbr\u003e (lbs\/kft)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003emin.\u003cbr\u003e bending\u003cbr\u003e radius (in)\u003c\/td\u003e\n\u003ctd\u003e†\u003cbr\u003e amp.\u003cbr\u003e (amps)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e resistance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e reactance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e†\u003cbr\u003e amp.\u003cbr\u003e (amps)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e resistance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd\u003e+\/- sequence\u003cbr\u003e imp.\u003cbr\u003e reactance\u003cbr\u003e (µΩ\/ft)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eprysmian\u003cbr\u003e cable\u003cbr\u003e part\u003cbr\u003e number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003e(a)\u003c\/td\u003e\n\u003ctd\u003e(b)\u003c\/td\u003e\n\u003ctd\u003e(c)\u003c\/td\u003e\n\u003ctd\u003e(d)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e‡105°c in duct\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e‡105°c direct buried\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"16\" style=\"text-align: center;\"\u003e35kv 100% copper single phase - full neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1-0-solid-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-uti\"\u003e1\/0 solid cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e16-#12\u003c\/td\u003e\n\u003ctd\u003e0.325\u003c\/td\u003e\n\u003ctd\u003e1.07\u003c\/td\u003e\n\u003ctd\u003e1.16\u003c\/td\u003e\n\u003ctd\u003e1.43\u003c\/td\u003e\n\u003ctd\u003e1328\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e298\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1-0-solid-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-uti\"\u003eQQ7030A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-uti-1\"\u003e1\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e16-#12\u003c\/td\u003e\n\u003ctd\u003e0.364\u003c\/td\u003e\n\u003ctd\u003e1.11\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003ctd\u003e1.47\u003c\/td\u003e\n\u003ctd\u003e1371\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e236\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-uti-1\"\u003eQQ8030A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-2-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utili\"\u003e2\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e13-#10\u003c\/td\u003e\n\u003ctd\u003e0.408\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003ctd\u003e1.24\u003c\/td\u003e\n\u003ctd\u003e1.56\u003c\/td\u003e\n\u003ctd\u003e1620\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e341\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-2-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utili\"\u003eQQ9030A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-3-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utili\"\u003e3\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e16-#10\u003c\/td\u003e\n\u003ctd\u003e0.458\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003ctd\u003e1.29\u003c\/td\u003e\n\u003ctd\u003e1.61\u003c\/td\u003e\n\u003ctd\u003e1860\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e306\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e386\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-3-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utili\"\u003eQQA030A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-4-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utili\"\u003e4\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e16-#9\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003ctd\u003e1.26\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003ctd\u003e1.75\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e348\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e434\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-4-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utili\"\u003eQQB030A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"16\" style=\"text-align: center;\"\u003e35kv 100% copper three phase - one-third neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1-0-solid-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage\"\u003e1\/0 solid cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e9-#14\u003c\/td\u003e\n\u003ctd\u003e0.325\u003c\/td\u003e\n\u003ctd\u003e1.07\u003c\/td\u003e\n\u003ctd\u003e1.16\u003c\/td\u003e\n\u003ctd\u003e1.40\u003c\/td\u003e\n\u003ctd\u003e1105\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003ctd\u003e132\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e299\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1-0-solid-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage\"\u003eQQ7020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003e1\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e9-#14\u003c\/td\u003e\n\u003ctd\u003e0.364\u003c\/td\u003e\n\u003ctd\u003e1.11\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003ctd\u003e1147\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003eQQ8020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-2-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003e2\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e11-#14\u003c\/td\u003e\n\u003ctd\u003e0.408\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003ctd\u003e1.24\u003c\/td\u003e\n\u003ctd\u003e1.48\u003c\/td\u003e\n\u003ctd\u003e1292\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e267\u003c\/td\u003e\n\u003ctd\u003e107\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e337\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-2-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003eQQ9020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-3-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003e3\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e14-#14\u003c\/td\u003e\n\u003ctd\u003e0.458\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003ctd\u003e1.29\u003c\/td\u003e\n\u003ctd\u003e1.53\u003c\/td\u003e\n\u003ctd\u003e1476\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e302\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003ctd\u003e376\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-3-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003eQQA020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-4-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003e4\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e18-#14\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003ctd\u003e1.26\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003ctd\u003e1.59\u003c\/td\u003e\n\u003ctd\u003e1705\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-4-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003eQQB020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-250-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003e250 MCM cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e21-#14\u003c\/td\u003e\n\u003ctd\u003e0.561\u003c\/td\u003e\n\u003ctd\u003e1.31\u003c\/td\u003e\n\u003ctd\u003e1.40\u003c\/td\u003e\n\u003ctd\u003e1.70\u003c\/td\u003e\n\u003ctd\u003e1980\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e443\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-250-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003eQQC020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-350-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003e350 MCM cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e18-#12\u003c\/td\u003e\n\u003ctd\u003e0.664\u003c\/td\u003e\n\u003ctd\u003e1.42\u003c\/td\u003e\n\u003ctd\u003e1.51\u003c\/td\u003e\n\u003ctd\u003e1.84\u003c\/td\u003e\n\u003ctd\u003e2520\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e501\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-350-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003eQQD020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-500-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003e500 MCM cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e17-#10\u003c\/td\u003e\n\u003ctd\u003e0.794\u003c\/td\u003e\n\u003ctd\u003e1.55\u003c\/td\u003e\n\u003ctd\u003e1.67\u003c\/td\u003e\n\u003ctd\u003e2.04\u003c\/td\u003e\n\u003ctd\u003e3385\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e557\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-500-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003eQQE020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-750-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003e750 MCM cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e20-#9\u003c\/td\u003e\n\u003ctd\u003e0.974\u003c\/td\u003e\n\u003ctd\u003e1.73\u003c\/td\u003e\n\u003ctd\u003e1.85\u003c\/td\u003e\n\u003ctd\u003e2.25\u003c\/td\u003e\n\u003ctd\u003e4635\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e616\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e624\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-750-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-u\"\u003eQQF020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1000-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-\"\u003e1000 MCM cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e21-#8\u003c\/td\u003e\n\u003ctd\u003e1.124\u003c\/td\u003e\n\u003ctd\u003e1.88\u003c\/td\u003e\n\u003ctd\u003e2.00\u003c\/td\u003e\n\u003ctd\u003e2.43\u003c\/td\u003e\n\u003ctd\u003e5867\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e671\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e682\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/medium-voltage-double-seal-cable-5kv-46kv\/double-seal-epr-cable\/prysmian-cable-1000-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-\"\u003eQQG020A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\u003c!--\n.listing-a .item-details table td {\n            padding: 10px 1px;\n--\u003e\u003c\/style\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186420105279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_fa573a67-8a06-4925-9d5d-a4bed21d86fb.jpg?v=1571729049"},{"product_id":"prysmian-cable-4-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utility-cables-qqb030a","title":"Prysmian Cable 4\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQB030A","description":"Prysmian Cable 4\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQB030A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQB030A. Click for a free quote. 4\/0 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQB030A, 4\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQB030A, QQB030A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e4\/0 awg cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e16-#9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e348\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQB030A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186430001215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_410693fc-9bf3-4078-a51b-f7d494e112bc.jpg?v=1571729053"},{"product_id":"prysmian-cable-4-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qqb020a","title":"Prysmian Cable 4\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQB020A","description":"Prysmian Cable 4\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQB020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQB020A. Click for a free quote. 4\/0 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQB030A, 4\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQB020A, QQB020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e4\/0 awg cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e18-#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e251\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQB020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186430066751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_8e3e05d6-32b0-465e-8796-aa7e2bdca468.jpg?v=1571729053"},{"product_id":"prysmian-cable-500-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qqe020a","title":"Prysmian Cable 500 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQE020A","description":"Prysmian Cable 500 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQE020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 500 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQE020A. Click for a free quote. 500 MCM.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQE030A, 500 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQE020A, QQE020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e500 MCM cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e17-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e2.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e3385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e557\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQE020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186471911487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_56e752fc-9e53-44b7-8b25-8ababa2cb0c0.jpg?v=1571729059"},{"product_id":"prysmian-cable-750-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qqf020a","title":"Prysmian Cable 750 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQF020A","description":"Prysmian Cable 750 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQF020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 750 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQF020A. Click for a free quote. 750 MCM.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQF030A, 750 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQF020A, QQF020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e750 MCM cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e20-#9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.974\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e2.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e4635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e616\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQF020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186485248063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_1006b3ab-0d77-42f8-9138-f483764d195f.jpg?v=1571729078"},{"product_id":"prysmian-cable-1-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utility-cables-qq8030a","title":"Prysmian Cable 1\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ8030A","description":"Prysmian Cable 1\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ8030A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ8030A. Click for a free quote. 1\/0 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQ8030A, 1\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ8030A, QQ8030A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e1\/0 awg cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e16-#12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQ8030A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187763953727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_f21c1a0b-eb8d-4d67-b47d-59ee0adad9c6.jpg?v=1571729315"},{"product_id":"prysmian-cable-1-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qq8020a","title":"Prysmian Cable 1\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ8020A","description":"Prysmian Cable 1\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ8020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ8020A. Click for a free quote. 1\/0 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQ8030A, 1\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ8020A, QQ8020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e1\/0 awg cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e9-#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e496\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQ8020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187764084799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_bad75d10-f0e2-461a-9a3b-7ece88206fa3.jpg?v=1571729315"},{"product_id":"prysmian-cable-1-0-solid-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utility-cables-qq7030a","title":"Prysmian Cable 1\/0 Solid 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ7030A","description":"Prysmian Cable 1\/0 Solid 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ7030A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 Solid 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ7030A. Click for a free quote. 1\/0 Solid.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQ7030A, 1\/0 Solid 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ7030A, QQ7030A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e1\/0 Solid cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e16-#12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1328\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQ7030A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187797278783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_809826bb-6f56-447a-b75d-cfbe5e8e598c.jpg?v=1571729335"},{"product_id":"prysmian-cable-1-0-solid-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qq7020a","title":"Prysmian Cable 1\/0 Solid 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ7020A","description":"Prysmian Cable 1\/0 Solid 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ7020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 Solid 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ7020A. Click for a free quote. 1\/0 Solid.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQ7030A, 1\/0 Solid 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ7020A, QQ7020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e1\/0 Solid cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e9-#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e299\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e492\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQ7020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187797344319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_b9662b4a-def3-404f-8a9c-4b8998eb2b25.jpg?v=1571729335"},{"product_id":"prysmian-cable-1000-mcm-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qqg020a","title":"Prysmian Cable 1000 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQG020A","description":"Prysmian Cable 1000 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQG020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1000 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQG020A. Click for a free quote. 1000 MCM.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQG030A, 1000 MCM 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQG020A, QQG020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e1000 MCM cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e21-#8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e1.124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e2.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e2.43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e5867\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e671\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e682\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQG020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187820937279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_a84f51e5-1e5f-4f73-99cb-c8b05d3732d2.jpg?v=1571729338"},{"product_id":"prysmian-cable-2-0-awg-35kv-100-copper-epr-doubleseal-single-phase-full-neutral-medium-voltage-utility-cables-qq9030a","title":"Prysmian Cable 2\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ9030A","description":"Prysmian Cable 2\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ9030A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ9030A. Click for a free quote. 2\/0 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQ9030A, 2\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Single Phase Full Neutral Medium Voltage Utility Cables QQ9030A, QQ9030A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e2\/0 awg cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e13-#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQ9030A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187878903871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_77067fe8-3b53-4dff-a931-9918909ce80d.jpg?v=1571729360"},{"product_id":"prysmian-cable-2-0-awg-35kv-100-copper-epr-doubleseal-three-phase-one-third-neutral-medium-voltage-utility-cables-qq9020a","title":"Prysmian Cable 2\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ9020A","description":"Prysmian Cable 2\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ9020A\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ9020A. Click for a free quote. 2\/0 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QQ9030A, 2\/0 AWG 35kV 100% Copper EPR DOUBLESEAL Three Phase One Third Neutral Medium Voltage Utility Cables QQ9020A, QQ9020A, Medium Voltage Utility Cables, EPROTENAX EPR Insulation Cable, LLDPE Jacket Cable, Solid Aluminum Alloy Conductor Cable, Soft Conductor Annealed Copper Cable, DOUBLESEAL Cable, Medium Voltage Double Seal Cable, Double Seal EPR Cable, 35kV 100% EPR DOUBLESEAL Copper Medium Voltage Utility Cables\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e: Solid or Class B Compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM. Stranded conductors are water-blocked with STRANDSEAL® conductor filling compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to prevent longitudinal water penetration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with solid or filled strand aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water swellable agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • Black LLDPE jacket with no stripes\u003cbr\u003e • Multiplex cables\u003cbr\u003e • Tinned round and flat strap neutrals\u003cbr\u003e • Compact stranded conductors\u003cbr\u003e • UL MV-90 rating if required\u003cbr\u003e • 46kV\u003cbr\u003e • RUS Bulletin 1728F-U1 where applicable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003cbr\u003e • Conduit In Air\u003cbr\u003e • Direct Buried\u003cbr\u003e • Underground Duct\u003cbr\u003e • Isolated In Air\u003cbr\u003e • Wet Locations\u003cbr\u003e • Dry Locations\u003cbr\u003e • With Messenger\u003cbr\u003e • Utility Primary\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications and ratings\u003c\/strong\u003e:\u003cbr\u003e • AEIC- AEIC CS8\u003cbr\u003e • ICEA- ICEA S-94-649\u003cbr\u003e • ICEA- ICEA T-31-610\u003cbr\u003e • ICEA- ICEA T-34-664\u003cbr\u003e • For 105°C continuous, 140°C emergency, 250°C short-circuit operation\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor\u003c\/td\u003e\n\u003ctd\u003e2\/0 awg cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral\u003c\/td\u003e\n\u003ctd\u003e11-#14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n\u003ctd\u003e0.408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n\u003ctd\u003e1.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n\u003ctd\u003e1.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n\u003ctd\u003e1292\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e267\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - ‡105°c in duct\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e† ampacity (amps) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- ‡105°c direct buried\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n\u003ctd\u003eQQ9020A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187878969407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20EPR_20DOUBLESEAL-lg_7394b7a7-6a42-41e6-be9f-877dc3a388ac.jpg?v=1571729360"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/5-46kV_20EPR_20DOUBLESEAL-lg_600x_7a658b7e-4157-41c8-b34c-f69a537478af.jpg?v=1527397985","url":"https:\/\/nassauelectricalspot.com\/collections\/prysmian-cable-35kv-100-epr-doubleseal-copper-medium-voltage-utility-cables.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}