{"title":"Prysmian And Draka Cable Low Voltage Airguard VFD 600 Volt Power Cable","description":"","products":[{"product_id":"prysmian-and-draka-cable-1-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394049","title":"Prysmian And Draka Cable 1\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394049","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 1\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394049\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  1\/0 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 1\/0 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394049\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 1\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394049.Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #1\/0 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e55\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e10 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.360\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.476\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e1.445\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e1719\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e17.3\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e170\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT06\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394049\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185872551999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg.jpg?v=1571728919"},{"product_id":"prysmian-and-draka-cable-10-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394043","title":"Prysmian And Draka Cable 10 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394043","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 10 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394043\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 10 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394043.Click for a free quote.\n        \"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  10 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 10AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394043.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #10 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e14 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.113\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.177\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.725\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e364\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e8.7\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e30\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT03\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394043\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185878614079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_091c30f8-8c23-4560-884d-3ca4bc272f21.jpg?v=1571728921"},{"product_id":"prysmian-and-draka-cable-12-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394041","title":"Prysmian And Draka Cable 12 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394041","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 12 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394041\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD 12 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 12 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394041.\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 12 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394041.  Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #12 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround\n                    wires\n                    size AWG\u003c\/td\u003e\n                    \u003ctd\u003e16AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.089\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.153\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.670\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e296\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e8.1\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e20\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT03\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394041\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185888313407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_abc68afb-8f2e-4e41-890c-a06da9ff44dd.jpg?v=1571728938"},{"product_id":"prysmian-and-draka-cable-14-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394039","title":"Prysmian And Draka Cable 14 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394039","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 14 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394039\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of 600 Prysmian And Draka Cable 14 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394039. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD 14 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 14 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394039.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/c #14 AWG\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround\n                    wires\n                    size AWG\u003c\/td\u003e\n                    \u003ctd\u003e18 AWG\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.071\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.135\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.630\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e247\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e7.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394039\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185907744831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_54bb81c9-c4e9-48cd-ad84-e33431721fee.jpg?v=1571728944"},{"product_id":"prysmian-and-draka-cable-2-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394048","title":"Prysmian And Draka Cable 2 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394048","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 2 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394048\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 2 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394048.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  2 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 2 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394048\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e 3\/C #2 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e45\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e10 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.283\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.379\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e1.225\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e1236\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e14.7\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e130\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT15\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394048\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185937301567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_8248f947-3f05-40a2-b378-535316fb52ac.jpg?v=1571728969"},{"product_id":"prysmian-and-draka-cable-2-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394050","title":"Prysmian And Draka Cable 2\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394050","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 2\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394050\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  2\/0 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 2\/0 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394050\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 2\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394050.Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #2\/0 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e55\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e10 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.402\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.518\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e1.540\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e2017\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e18.5\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e195\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT06\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394050\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185985404991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_441464c8-78ea-47d2-8668-3051333d09ea.jpg?v=1571728975"},{"product_id":"prysmian-and-draka-cable-250-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127514","title":"Prysmian And Draka Cable 250 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127514","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 250 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127514\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD 250 MCM 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote 250 MCM 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 20127514\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 250 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127514.Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #250 MCM\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e65\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e8 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.558\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.70\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e1.98\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e4024\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e14\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e290\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT07\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e20127514\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185999986751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_1b079308-92d9-49d4-af3d-b5034db993bb.jpg?v=1571728998"},{"product_id":"prysmian-and-draka-cable-350-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127942","title":"Prysmian And Draka Cable 350 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127942","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 350 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127942\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 350 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127942.Click for a free quote.\n        \"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD 350 MCM 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote 350 MCM 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 20127942\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #350 MCM\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e65\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e7 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.661\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.80\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e2.22\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e5312\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e16\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e350\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT08\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e20127942 \u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187582877759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_93de2c27-50a8-429f-bbd6-3d8d657d81e4.jpg?v=1571729223"},{"product_id":"prysmian-and-draka-cable-4-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394047","title":"Prysmian And Draka Cable 4 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394047","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 4 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394047\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 4 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394047.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  4 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 4 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394047\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e 3\/C #4 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e45\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e12 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.225\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.321\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e1.095\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e898\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum ending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e13.2\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e95\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT15\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394046\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187589660735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_56a9521f-9427-4355-98ab-9cbbc2e4fff1.jpg?v=1571729245"},{"product_id":"prysmian-and-draka-cable-4-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127515","title":"Prysmian And Draka Cable 4\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127515","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 4\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127515\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  4\/0 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 4\/0 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 20127515\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 4\/0 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127515.Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #4\/0 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e55\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e8 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.512\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.63\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e1.83\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable\n                    weight lbs\/mft\u003c\/td\u003e\n                    \u003ctd\u003e3450\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e13\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e260\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT07\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e20127515\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187604832319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_a397b264-e922-41ba-abb0-bd760149127f.jpg?v=1571729249"},{"product_id":"prysmian-and-draka-cable-400-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127513","title":"Prysmian And Draka Cable 400 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127513","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 400 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127513\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 400 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20127513.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  400 MCM 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote 400 MCM 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 20127513\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #400 MCM\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e65\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e7 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.706\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.85\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e2.41\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e6008\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e17\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e380\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT09\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e20127513\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187607322687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_981de4f1-3b74-4882-9583-9cd64ce86c80.jpg?v=1571729249"},{"product_id":"prysmian-and-draka-cable-500-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20147056","title":"Prysmian And Draka Cable 500 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20147056","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 500 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20147056\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 500 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 20147056.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  500 MCM 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote 500 MCM 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 20147056\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #500 MCM\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e65\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e6 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.789\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.93\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e2.53\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e7194\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e18\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e430\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT09\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable part Number\u003c\/td\u003e\n                    \u003ctd\u003e20147056 \u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187619151935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_333f6b06-15a4-404a-a6e2-cb7bb7c3d379.jpg?v=1571729250"},{"product_id":"prysmian-and-draka-cable-6-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394046","title":"Prysmian And Draka Cable 6 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394046","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 6 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394046\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 6  AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394046 Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  6 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 6 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394046.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #6 AWG \u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e45\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e12 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.178\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.274\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.990\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e696\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e11.9\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e75\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT04\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394046\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187624460351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_548c14a9-e46f-47b7-8c29-6b335d7d5094.jpg?v=1571729251"},{"product_id":"prysmian-and-draka-cable-750-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-306451a","title":"Prysmian And Draka Cable 750 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 306451A","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 750 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 306451A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 750 MCM 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 306451.Click for a free quote.\n        \"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  750 MCM 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote 750 MCM 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 20147056\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #750 MCM\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e80\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor  #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e5 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.973\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e1.09\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e3.02\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e10518\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e22\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e535 \u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e--------\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e306451A\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187654377535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_3b92f307-8e15-4f1d-b365-c2268562da9d.jpg?v=1571729256"},{"product_id":"prysmian-and-draka-cable-8-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394045","title":"Prysmian And Draka Cable 8 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394045","description":"\n    \n        \u003ctitle\u003ePrysmian And Draka Cable 8 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394045\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian And Draka Cable 8 AWG 3 Conductors Low Voltage AIRGUARD VFD 600 Volt Power Cable 394045. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian And Draka Cable, Low Voltage Cable, AIRGUARD VFD 600 Cable, Volt Power Cable, Prysmian  And  Draka Price, Low Voltage Price, AIRGUARD VFD  8 AWG 3 Conductors 600 Cable Price, Volt Power Cable Price, Prysmian And Draka Quote, 8 AWG 3 Conductors Low Voltage Quote, AIRGUARD VFD 600 Quote, Volt Power Quote 394045.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003ePrysmian’s Low Voltage AIRGUARD™ Power Cables\n        are primarily designed for applications in the harsh\n        environments found in the heavy industrial and offshore\n        markets. Its rugged polymeric Airbag™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance\n        in areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation, and substantially reduced cost of cable glands.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eClass B stranded bare, soft drawn coppercircuit conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eHeat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of UL-44\n        for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers: \u003c\/strong\u003eExtruded filler belt\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires: \u003c\/strong\u003eClass B stranded bare, soft drawn\n        copper ground conductors (3)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eEmi Shield: \u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolymeric Armor\/Environmental Barrier: \u003c\/strong\u003eFoamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003cbr\u003e\n        • ICEA S-82-558(NEMA WC70) Power Cable Rating\u003cbr\u003e\n        • UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        Oil Resistant\u003cbr\u003e\n        • UL 1202\/FT-4 Flame Retardant\u003cbr\u003e\n        • UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating\u003cbr\u003e\n        • UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1\n        Hazardous Locations\u003cbr\u003e\n        • NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003cbr\u003e\n        • CSA 22.2 No. 03 -40oC\/-35oC Cold Bend\/\n        Cold Impact\u003cbr\u003e\n        • MSHA Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber\n                    and Circuit Conductor Size\u003c\/td\u003e\n                    \u003ctd\u003e3\/C #8 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n                    \u003ctd\u003e45\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNumber of Grounding Conductor #\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGround Wires Size AWG\u003c\/td\u003e\n                    \u003ctd\u003e14 AWG\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eConductor Diameter Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.142\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Insulation\n                    (od) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.238\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Overall Cable\n                    (od ) Inches\u003c\/td\u003e\n                    \u003ctd\u003e0.905\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Cable Weight lbs\/Mft\u003c\/td\u003e\n                    \u003ctd\u003e544\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bending Radius Inches\u003c\/td\u003e\n                    \u003ctd\u003e10.9\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ Ampacity\n                    (amps) ‡90°c\u003c\/td\u003e\n                    \u003ctd\u003e55\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eGland, Explosion Proof, Class 1 Division 1, Barrier Type\u003c\/td\u003e\n                    \u003ctd\u003e424BT04\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePrysmian and Draka Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003e394045\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187658670143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_f2b5e252-efda-4aee-9f05-871effdbd3cc.jpg?v=1571729257"},{"product_id":"prysmian-and-draka-cable-low-voltage-airguard-vfd-600-volt-power-cable","title":"Prysmian Low Voltage AIRGUARD™ VFD Cable 600V","description":"\u003cp\u003eVFD Power Cable soft drawn copper conductors are insulated with XLP as per UL-44. XLP insulation offers protection to the conductors against heat and moisture damage. Insulated conductors are wrapped with an extruded filler belt and then twisted together with a grounding wire to form an assembly. This assembly is shielded with a metallic tape which holds the conductors firmly together and armored by a polymeric airbag that is sheathed with a thermoplastic material.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy go for this cable?\u003c\/strong\u003e \u003cbr\u003eThe cross linked polyethylene (XLP) insulation ensures no contact between the copper conductors and the grounding wire, thus improving the power conductivity of the cable. Emi shield and the extruded filler belt both ensures that the phase identification of the core is held firmly in place, hence keeping the conductors away from overlapping each other.\u003c\/p\u003e\n\u003cp\u003ePolymeric armor acts as barrier to abrasion. It is a tough coat that prevents harsh environmental conditions from damaging the cable. Heavy duty industrial and offshore environment is very demanding more so if it presents the cable with corrosive chemicals, wear and tear due to moving parts. Therefore only special cables with superior polymeric armor can withstand such conditions and not an ordinary standard cable protection. Go for Prysmian’s VDF Power Cable to enjoy a long term power service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e \u003cbr\u003eA power cable with more advanced adaptive insulation and armor features like this Prysmian Cable, is meant to serve in punishing conditions and is applied in various industrial fields and marine offshore drills.\u003c\/p\u003e\n\u003cp\u003eThere are lots of low voltage onshore and offshore cables at Nassau Electrical and other types available include; Prysmian \u003ca href=\"https:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-usa-600-volt-3-c-airguard-low-voltage-commercial-industrial-cables\"\u003e3\/C Air-guard Commercial\u003c\/a\u003e and Industrial Cable and Prysmian 2 AWG Copper Air-guard Cable.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003enumber and circuit \u003cbr\u003e conductor size\u003c\/td\u003e\n\u003ctd\u003eInsulation Thickness Mils\u003c\/td\u003e\n\u003ctd\u003egland, explosion proof, \u003cbr\u003e class 1, division 1, barrier type\u003c\/td\u003e\n\u003ctd\u003eprysmian and draka \u003cbr\u003e cable Part Number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-14-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394039\"\u003e3\/C #14 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e424BT03\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-14-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394039\"\u003e394039\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-14-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394039\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-12-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394041\"\u003e3\/C #12 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e424BT03\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-12-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394041\"\u003e394041\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-12-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394041\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-10-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394043\"\u003e3\/C #10 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e424BT03\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-10-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394043\"\u003e394043\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-10-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394043\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-8-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394045\"\u003e3\/C #8 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e424BT04\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-8-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394045\"\u003e394045\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-8-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394045\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-6-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394046\"\u003e3\/C #6 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e424BT04\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-6-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394046\"\u003e394046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-6-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394046\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-4-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394047\"\u003e3\/C #4 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e424BT15\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-4-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394047\"\u003e394047\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-4-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394047\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-2-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394048\"\u003e3\/C #2 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e424BT15\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-2-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394048\"\u003e394048\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-2-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394048\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-1-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394049\"\u003e3\/C #1\/0 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e424BT06\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-1-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394049\"\u003e394049\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-1-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394049\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-2-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394050\"\u003e3\/C #2\/0 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e424BT06\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-2-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394050\"\u003e394050\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-2-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-394050\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-4-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127515\"\u003e3\/C #4\/0 AWG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e424BT07\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-4-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127515\"\u003e20127515\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-4-0-awg-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127515\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-250-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127514\"\u003e3\/C#250 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e424BT07\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-250-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127514\"\u003e20127514\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-250-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127514\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-350-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127942\"\u003e3\/C #350 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e424BT08\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-350-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127942\"\u003e20127942\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-350-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127942\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-400-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127513\"\u003e3\/C #400 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e424BT09\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-400-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127513\"\u003e20127513\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-400-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20127513\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-500-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20147056\"\u003e3\/C #500 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e424BT09\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-500-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20147056\"\u003e20147056\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-500-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-20147056\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-750-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-306451a\"\u003e3\/C #750 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e--------\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-750-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-306451a\"\u003e306451A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/copper-tray-cable-tc\/low-volt-onshore-and-offshore-cable\/prysmian-and-draka-cable-750-mcm-3-conductors-low-voltage-airguard-vfd-600-volt-power-cable-306451a\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187701760063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Airguard-lg_59344f29-8272-4455-8e11-0c43e17841f2.jpg?v=1571729278"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/prysmian-and-draka-cable-low-voltage-airguard-vfd-600-volt-power-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}