{"title":"Interlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors","description":"","products":[{"product_id":"interlocked-armor-power-cable-1-gauge-3-conductor-15kv","title":"Interlocked Armor Power Cable - 1 Gauge - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 1 Gauge - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"This cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 1 Gauge - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2835\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151867068479,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg.jpg?v=1571727223"},{"product_id":"interlocked-armor-power-cable-1-0-gauge-3-conductor-15kv","title":"Interlocked Armor Power Cable - 1\/0 Gauge - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 1\/0 Gauge - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"This cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable – 1\/0 Gauge - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151867658303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_64575c5f-a618-45c9-844b-d192a9b26ffa.jpg?v=1571727223"},{"product_id":"interlocked-armor-power-cable-2-gauge-3-conductor-15kv","title":"Interlocked Armor Power Cable - 2 Gauge - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 2 Gauge - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"The Interlocked Armor Power Cable - 2 Gauge - 3 Conductor - 15KV cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties. \"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 2 Gauge – 3 Conductor – 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable - 2 Gauge - 3 Conductor - 15KV cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable - 2 Gauge - 3 Conductor - 15KV is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151868018751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_e273c612-5f07-4160-a730-45afd7d99141.jpg?v=1571727223"},{"product_id":"interlocked-armor-power-cable-2-0-gauge-3-conductor-15kv","title":"Interlocked Armor Power Cable - 2\/0 Gauge - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 2\/0 Gauge - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"The Interlocked Armor Power Cable – 2\/0 Gauge - 3 Conductor - 15KV cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 2\/0 Gauge - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable – 2\/0 Gauge - 3 Conductor - 15KV cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable – 2\/0 Gauge - 3 Conductor - 15KV is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  The 2\/0-gauge construction of this cable is recommended if transmission of voltages nearing the maximum 15KV is required.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-                \u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151868182591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_9280f9be-3d04-4652-9f7a-5f97f99df962.jpg?v=1571727223"},{"product_id":"interlocked-armor-power-cable-250-mcm-3-conductor-15kv","title":"Interlocked Armor Power Cable - 250 MCM - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 250 MCM - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"This cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 250 MCM - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151868444735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_4e7a2b95-4f21-4ac2-99d1-702f2a8a4fc7.jpg?v=1571727223"},{"product_id":"interlocked-armor-power-cable-3-0-gauge-3-conductor-15kv","title":"Interlocked Armor Power Cable - 3\/0 Gauge - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 3\/0 Gauge - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"This cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 3\/0 Gauge - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151868510271,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_bef90233-3560-408a-ac90-fcf363c07566.jpg?v=1571727223"},{"product_id":"interlocked-armor-power-cable-350-mcm-3-conductor-15kv","title":"Interlocked Armor Power Cable - 350 MCM - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 350 MCM - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"The Interlocked Armor Power Cable – 350MCM - 3 Conductor - 15KV cable employs three 350MCM soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 350 MCM - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable – 350MCM - 3 Conductor - 15KV cable employs three 350MCM soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable – 350MCM - 3 Conductor - 15KV is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424MA09V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151869460543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_27d7056d-528e-4e47-a942-6468304a28cb.jpg?v=1571727224"},{"product_id":"interlocked-armor-power-cable-4-0-gauge-3-conductor-15kv","title":"Interlocked Armor Power Cable - 4\/0 Gauge - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 4\/0 Gauge - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"The Interlocked Armor Power Cable – 4\/0 Gauge - 3 Conductor - 15KV cable employs three 4\/0 gauge soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties. \"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 4\/0 Gauge - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable – 4\/0 Gauge - 3 Conductor - 15KV cable employs three 4\/0 gauge soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable – 4\/0 Gauge - 3 Conductor - 15KV is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The wide-diameter cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151869657151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_698bed35-5208-4945-96b1-9214301581c0.jpg?v=1571727224"},{"product_id":"interlocked-armor-power-cable-500-mcm-3-conductor-15kv","title":"Interlocked Armor Power Cable - 500 MCM - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 500 MCM - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"This cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 500 MCM - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424MA10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151869984831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_e8a67d61-7524-415f-9f31-0445537772c6.jpg?v=1571727224"},{"product_id":"interlocked-armor-power-cable-750-mcm-3-conductor-15kv","title":"Interlocked Armor Power Cable - 750 MCM - 3 Conductor - 15KV","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 750 MCM - 3 Conductor - 15KV\u003cmeta name=\"Description\" content=\"This cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties. \"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable - 750 MCM - 3 Conductor - 15KV,EPR Insulation, Insulated Cables,  Jacketed Cables,Aluminum Armor Cable,Copper Conductor Cable,Armor Cable,Shielded Cable,133% Insulation Level Aluminum Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, a compliance and regulations organization, is listed Type MC and is approved to transmit up to 600 volts at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eThis cable passes the UL 1581 70,000 BTU\/Hr flame test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components used in this cable are soft bare annealed Class B copper. \u003c\/li\u003e\n\u003cli\u003eAnnealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are individually insulated in a ethylene propylene rubber (EPR)\u003c\/li\u003e\n\u003cli\u003eThe insulation helps to protect the cables from corrosive elements and also adds mechanical strength to the cable. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are shielded by an uncoated copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe grounding wire that is included in the assembly is a soft bare annealed Class B copper conductor.\u003c\/li\u003e\n\u003cli\u003eThe grounding wire ensures steady conductivity over the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is an aluminum interlocked tape armor that is also available in galvanized steel.\u003c\/li\u003e\n\u003cli\u003eThe aluminum armor is a great economical alternative to installing cable in conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior coating is a red sunlight resistant PVC jacket.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424MA11V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151870214207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_45e1463d-a7e7-46b8-b59b-db2ea290cb82.jpg?v=1571727224"},{"product_id":"interlocked-armor-power-cable-shielded-epr-insulation-133-insulation-level-aluminum-armor-copper-conductors","title":"Interlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors cable employs 3 soft bare annealed Class B copper conductors that comply with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.  The copper conductors are insulated with an ethylene propylene rubber (EPR) insulation that adds mechanical strength to the cable and also helps to protect the conductors from corrosive elements.  An uncoated copper tape shield directly covers the insulation.  The shield helps to prevent the electric current from interfering with other devices nearby and also helps to prevent electric shock.  The assembly includes a soft bare annealed copper grounding conductor which meets ASTM standards B-3 and B-8.  The grounding conductor serves to ensure steady conductivity throughout the life of the cable. The external armor of the assembly is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor’s rigid frame protects the conductors from being jarred or interfered with by outside objects.  The aluminum armor is also an effective economical alternative to wire in conduit systems.  The outer surface of the cable is a black sunlight-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003eThe Interlocked Armor Power Cable Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductors cable is UL approved for use in wet or dry locations at continuous temperatures up to 90°C.  In emergency overload situations, the cable can tolerate temperatures up to 130°C and in short circuit situations the cable can handle temperatures up to 250°C.  The cable can be installed indoors or outdoors, in cable trays, conduits, ducts, or direct burial in circuits producing 15,000 volts or less.  The interlocking armor on this cable makes it suitable for use in harsh climates and hazardous environments as specified by NEC. \u003c\/p\u003e\n\u003ctable width=\"100%\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center; font-size: 0.9em;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize (AWG \u003cbr\u003e or kcmil)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNo. of\u003cbr\u003e Conductors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eGround Wire\u003cbr\u003e Size AWG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eProduct \u003cbr\u003e Code\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-2-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003e2 Gauge\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eHW303 00203 \/\u003cbr\u003e HW30300203\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-2-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-1-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003e1 Gauge\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eHW303 00103 \/\u003cbr\u003e HW30300103\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-1-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-1-gauge-3-conductor-4\" style=\"color: #0101ff;\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eHW303 10103 \/\u003cbr\u003e HW30310103\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-1-gauge-3-conductor-4\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-2-0-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eHW303 20103 \/\u003cbr\u003e HW30320103\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-2-0-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-3-0-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eHW303 30103 \/\u003cbr\u003e HW30330103\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-3-0-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-4-0-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eHW303 40103 \/\u003cbr\u003e HW30340103\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-4-0-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-250-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003e250 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eHW303 25003 \/\u003cbr\u003e HW30325003\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-250-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-350-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003e350 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eHW303 35003 \/\u003cbr\u003e HW30335003\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-350-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-500-gauge-3-conductor-2\" style=\"color: #0101ff;\"\u003e500 MCM\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eHW303 50003 \/\u003cbr\u003e HW30350003\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-500-gauge-3-conductor-2\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-750-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003e750 MCM\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eHW303 75003 \/\u003cbr\u003e HW30375003\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-power-cable-750-gauge-3-conductor-3\" style=\"color: #0101ff;\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151870476351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW303-00203-lg_2d8cd0a2-6df8-42f6-b1da-7a827864d8f4.jpg?v=1571727225"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/206.jpg?v=1523946187","url":"https:\/\/nassauelectricalspot.com\/collections\/interlocked-armor-power-cable-shielded-epr-insulation-133-insulation-level-aluminum-armor-copper-conductors.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}