{"title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor","description":"","products":[{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThis type THN wire is widely recommended for use in applications that do not require any traces of Electromagnetic Interference, EMI. This because the cable has 100% shielding and does not allow any EMI radiations into the cable. It can be broadly used in do-it yourself home applications, industrial applications or in commercial purposes.\u003c\/p\u003e\n\u003cp\u003eThe cable is certified for use in hazardous indoor and outdoor applications in an operation range of up to 90°C in dry areas. For applications involving direct burial, 600V should not be exceeded. Some of these applications are;\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSoft bare copper conductor. The copper is fully annealed per ASTM B-3.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIt is fully stranded per ASTM B-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e• XPLE material insulator\u003cbr\u003e• PVC insulation which is flame retardant according to the Standard 62 of the UL listing, for TFN wire and cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003eTransparent nylon insulation jacket, standard 83 of UL listing for overall THWN wire and THHN cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e• 100% coverage with Aluminum-polymer foil\/tape.\u003cbr\u003e• This aluminum shield has 0% EMI penetration with 7 strands of flexible tin-plated copper drain wire which earths excess currents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003eAn overall UV – resistant PVC jacket, according to standard 1277 of UL listing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e• PVC jacket\u003cbr\u003e• Copper conductor\u003cbr\u003e• TFN and PVC insulation\u003cbr\u003e• 600-volt rating\u003cbr\u003e• Type HW153 cable\u003cbr\u003e• Oil and water resistance jacket and insulation\u003cbr\u003e• Sturdy, abrasion-proof jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e• IEEE 383 Flame test, 70000 BTU per hour.\u003cbr\u003e• ICEA flame test, 210000 BTU per hour.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003eFor color codes refer to Table E-2 of the ICEA Method 1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Approval Standards:\u003c\/strong\u003e\u003cbr\u003e• Type TC of UL listing\u003cbr\u003e• NEC article 336 and 725, approved for signal circuit applications and remote control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e• Cable trays\u003cbr\u003e• Ducts\u003cbr\u003e• Conduits\u003cbr\u003e• Lighting and power circuits\u003cbr\u003e• Control circuits\u003cbr\u003e• Aerial applications\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize AWG\u003c\/td\u003e\n\u003ctd\u003econductors\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003einsullation thinckness mils\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eproduct code\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--1\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01402 \/\u003cbr\u003eHW15301402\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--2\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01403 \/\u003cbr\u003eHW15301403\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--3\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01404 \/\u003cbr\u003eHW15301404\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--4\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01405 \/\u003cbr\u003eHW15301405\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--4\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--5\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01407 \/\u003cbr\u003eHW15301407\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--5\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--6\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01409 \/\u003cbr\u003eHW15301409\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--7\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01412 \/\u003cbr\u003eHW15301412\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--7\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--8\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01419 \/\u003cbr\u003eHW15301419\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--9\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01425 \/\u003cbr\u003eHW15301425\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket--9\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-10\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01437 \/\u003cbr\u003eHW15301437\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-10\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-11\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01202 \/\u003cbr\u003eHW15301202\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-11\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-12\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01203\u003cbr\u003eHW15301203\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-12\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-13\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01204 \/\u003cbr\u003eHW15301204\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-13\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-14\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01205 \/\u003cbr\u003eHW15301205\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-14\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-15\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01207 \/\u003cbr\u003eHW15301207\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-15\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-16\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01209 \/\u003cbr\u003eHW15301209\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-16\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-17\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01212 \/\u003cbr\u003eHW15301212\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-17\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-18\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01219 \/\u003cbr\u003eHW15301219\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-18\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-19\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eHW153 01237 \/\u003cbr\u003eHW15301237\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-19\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"height: 29px;\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-20\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eHW153 01002 \/\u003cbr\u003eHW15301002\u003c\/td\u003e\n\u003ctd style=\"height: 29px;\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-20\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-21\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eHW153 01003 \/\u003cbr\u003eHW15301003\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-21\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-22\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eHW153 01004 \/\u003cbr\u003eHW15301004\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-22\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-23\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eHW153 01005 \/\u003cbr\u003eHW15301005\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-23\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-24\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eHW153 01012 \/\u003cbr\u003eHW15301012\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/copper-control-cable\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-24\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428553279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_68632b09-27b1-4352-93dc-4e21a855fb14.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-10-awg-12-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 10 AWG - 12 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428586047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_aba0f54b-dad6-481d-bfa4-c6af543306a3.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-10-awg-2-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 10 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428618815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_03e7b2d6-be5b-4010-8703-1a87ab591f11.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-10-awg-3-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 10 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e169\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428651583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_1221470b-2f33-4ff6-ab0f-2e828bbf8d2f.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-10-awg-4-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 10 AWG - 4 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428684351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_573a4297-635e-450c-a52c-73841d1ffcf0.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-10-awg-5-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 10 AWG - 5 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428717119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_5d137466-1d17-449d-970e-5e40c3989de2.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-12-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 12 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428749887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_6e3fdaa0-48ba-4743-9166-acb72a9c58a9.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-19-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 19 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428815423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_7eaaa759-21bf-4001-af39-9c827d639232.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-2-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428848191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_6c7fbee3-3381-450e-b998-49f016592d23.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-3-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428880959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_5c6ceb90-74d9-4f1d-a5d3-74a7a86387b8.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-37-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 37 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01237\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428913727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_46c85637-c9b2-4be5-a6c8-3e3d7245c0ca.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-4-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 4 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428946495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_6ec9e88c-5a53-459d-a7d8-b3d311c2ad6c.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-5-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 5 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150428979263,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_b085c744-b411-49de-a75e-c18554929ffe.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-7-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 7 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150429110335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_3004abac-8362-48a5-929b-32117371ede7.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-12-awg-9-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 12 AWG - 9 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e297\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150430748735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_d3a93a69-3d28-474f-9532-0fff80cf0a3e.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-12-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 12 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01412\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e267\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150430781503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_65aa80c1-6698-4a28-8346-1a02b4461c46.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-19-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 19 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01419\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e396\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150430814271,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_2c5fb855-b8da-4039-8f0a-7c9846754426.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-2-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150430847039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_cc497f55-5527-42e3-b6b9-f490108564c9.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-25-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 25 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150430879807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_9102f0ed-6ad2-4804-8963-17288e968157.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-3-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150430912575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_497f11c0-8d8a-419f-a70a-2540a8c480e7.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-37-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 37 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01437\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150430945343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_f755dec5-0b68-477a-ac91-1c94b84e273f.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-4-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 4 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150430978111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_f61337a5-d593-41d8-bd42-a237b1eac039.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-5-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 5 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150431010879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_c579f252-3200-4d96-8685-a11088372099.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-7-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 7 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e153\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150431043647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_c204262c-6e03-4344-9e84-4896fa68fd15.jpg?v=1571727127"},{"product_id":"hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor-14-awg-9-conductors","title":"HW153 Tray Cable - Shielded Control Cable 600 Volt UL Type TC-ER* THHN or THWN Insulation PVC Jacket Copper Conductor - 14 AWG - 9 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"width: 421px;\"\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003eHW153 01409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW153\u003c\/li\u003e\n\u003cli\u003eTray Cable - Shielded Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type TC-ER*\u003c\/li\u003e\n\u003cli\u003eTFN Insulation\u003c\/li\u003e\n\u003cli\u003ePVC Jacket Copper Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e General purpose cable for use where shielding from ambient electrical interference is required in power, control and lighting circuits in a broad range of commercial and industrial applications. Approved for continuous operation at 90°C in dry locations, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Flame-retardant PVC per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e Clear nylon per UL Standard 62 for Type TFN wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Sunlight-resistant PVC per UL Standard 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e IEEE 383 70,000 BTU\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Type TC per Article 336 of the NEC.\u003c\/li\u003e\n\u003cli\u003eApproved for Class 1 remote-control and signaling circuits per Article 725 of the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150431109183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW152-01802-lg_e5aaa1b3-f50e-46d0-8d5c-2f207c92cc54.jpg?v=1571727127"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/hw153-tray-cable-shielded-control-cable-600-volt-ul-type-tc-er-thhn-or-thwn-insulation-pvc-jacket-copper-conductor.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}