{"title":"Helukabel JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable","description":"","products":[{"product_id":"helukabel-14-awg-12-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83698","title":"Helukabel 14 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83698","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83698\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83698.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 12 Cores Helukabel JZ-603, 83698\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e18,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e288,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e579,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83698\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133753737279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg.jpg?v=1571726457"},{"product_id":"helukabel-14-awg-18-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83699","title":"Helukabel 14 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83699","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83699\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83699.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 18 Cores Helukabel JZ-603, 83699\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e22,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e432,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e851,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83699\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133772644415,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_baf8e19f-ed7e-4418-bbfe-52b6a22915d5.jpg?v=1571726460"},{"product_id":"helukabel-14-awg-2-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83708","title":"Helukabel 14 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83708","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83708\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83708.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 2 Cores Helukabel JZ-603, 83708\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e9,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e48,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e125,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83708\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133780148287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_2a31572f-4406-4c7c-9a72-0301ff7ca5fe.jpg?v=1571726462"},{"product_id":"helukabel-14-awg-25-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83700","title":"Helukabel 14 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83700","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83700\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83700.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 25 Cores Helukabel JZ-603, 83700\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e26,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e600,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1175,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83700\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133793091647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_b55eff1c-9abe-4aea-9d9e-715af5bd5ffd.jpg?v=1571726465"},{"product_id":"helukabel-14-awg-3-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83694","title":"Helukabel 14 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83694","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83694\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83694.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 3 Cores Helukabel JZ-603, 83694\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e9,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e72,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e169,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83694\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133809672255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_6996b030-c234-4dfa-a062-c09a6c00e044.jpg?v=1571726468"},{"product_id":"helukabel-14-awg-34-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83701","title":"Helukabel 14 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83701","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83701\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83701.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 34 Cores Helukabel JZ-603, 83701\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e34 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e29,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e816,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1529,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83701\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133822779455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_c8d5b2a4-16bb-4c17-8aff-8fe3c1be477b.jpg?v=1571726470"},{"product_id":"helukabel-14-awg-4-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83695","title":"Helukabel 14 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83695","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83695\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83695.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 4 Cores Helukabel JZ-603, 83695\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e11,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e96,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e209,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83695\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133831430207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_03492b13-f66d-4564-97db-c0a3d64ccac5.jpg?v=1571726472"},{"product_id":"helukabel-14-awg-5-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83696","title":"Helukabel 14 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83696","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83696\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83696.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 5 Cores Helukabel JZ-603, 83696\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e12,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e120,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e256,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83696\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133842931775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_717d04ba-c8af-4afe-8c77-895b1dc7e1ec.jpg?v=1571726498"},{"product_id":"helukabel-14-awg-50-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83702","title":"Helukabel 14 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83702","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83702\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83702.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 50 Cores Helukabel JZ-603, 83702\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e50 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e35,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1200,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e2290,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83702\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133846110271,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_72bc4295-071a-4e1f-9e5f-0c3f4241db25.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-61-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83703","title":"Helukabel 14 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83703","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83703\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83703.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 61 Cores Helukabel JZ-603, 83703\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e61 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e38,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1464,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e2724,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83703\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133846765631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_c7041d85-143d-46c9-aa00-e7f2cd9da6dd.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-7-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83697","title":"Helukabel 14 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83697","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83697\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83697.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 14 AWG 7 Cores Helukabel JZ-603, 83697\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 2,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e14,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e168,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e340,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83697\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133848567871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_a94c192b-d9d4-4113-b6cb-4af0ff568d28.jpg?v=1571726502"},{"product_id":"helukabel-16-awg-12-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83687","title":"Helukabel 16 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83687","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83687\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83687.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 12 Cores Helukabel JZ-603, 83687\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e14,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e173,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e361,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83687\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133861773375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_fe61620e-ca28-40e3-8d81-774998282451.jpg?v=1571726508"},{"product_id":"helukabel-16-awg-18-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83688","title":"Helukabel 16 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83688","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83688\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83688.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 18 Cores Helukabel JZ-603, 83688\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e17,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e259,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e518,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83688\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133868621887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_d64565e7-39f0-4550-907b-9c65987b1ff0.jpg?v=1571726527"},{"product_id":"helukabel-16-awg-2-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83707","title":"Helukabel 16 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83707","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83707\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83707.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 2 Cores Helukabel JZ-603, 83707\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e28,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e91,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83707\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133874421823,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_21ee5899-912d-42b5-9261-086266f22da6.jpg?v=1571726530"},{"product_id":"helukabel-16-awg-25-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83689","title":"Helukabel 16 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83689","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83689\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83689.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 25 Cores Helukabel JZ-603, 83689\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e21,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e360,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e730,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83689\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133883498559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_d22f4098-8ef0-402e-96da-62574f567101.jpg?v=1571726534"},{"product_id":"helukabel-16-awg-3-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83683","title":"Helukabel 16 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83683","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83683\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83683.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 3 Cores Helukabel JZ-603, 83683\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e43,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e110,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83683\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133897162815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_69696e87-ff2b-45fb-a42a-5ae26f94a909.jpg?v=1571726552"},{"product_id":"helukabel-16-awg-34-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83690","title":"Helukabel 16 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83690","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83690\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83690.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 34 Cores Helukabel JZ-603, 83690\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e34 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e24,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e490,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e945,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83690\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133915873343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_640a4d3f-1265-47a5-8cbe-720a770bf746.jpg?v=1571726556"},{"product_id":"helukabel-16-awg-4-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83684","title":"Helukabel 16 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83684","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83684\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83684.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 4 Cores Helukabel JZ-603, 83684\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e58,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e141,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83684\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133927407679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_72811790-e40b-4764-b6ca-e0b69b931477.jpg?v=1571726559"},{"product_id":"helukabel-16-awg-41-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83691","title":"Helukabel 16 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83691","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83691\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83691.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 41 Cores Helukabel JZ-603, 83691\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e41 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e26,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e591,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1135,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83691\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133944709183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_7377d089-9a24-4635-95c9-629ede895907.jpg?v=1571726568"},{"product_id":"helukabel-16-awg-5-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83685","title":"Helukabel 16 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83685","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83685\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83685.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 5 Cores Helukabel JZ-603, 83685\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e9,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e72,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e167,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83685\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133955194943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_7370c9a9-a501-43f9-bbb7-f7fe816d4cb2.jpg?v=1571726570"},{"product_id":"helukabel-16-awg-50-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83692","title":"Helukabel 16 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83692","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83692\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83692.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 50 Cores Helukabel JZ-603, 83692\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e50 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e28,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e720,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1381,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83692\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133965254719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_441c0f43-ca64-48e4-ba62-86c010935a3a.jpg?v=1571726572"},{"product_id":"helukabel-16-awg-61-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83693","title":"Helukabel 16 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83693","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83693\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83693.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 61 Cores Helukabel JZ-603, 83693\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e61 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e31,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e878,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1640,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83693\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133972856895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_b2c683cd-3e7b-444d-94d2-7509bf32bd6e.jpg?v=1571726574"},{"product_id":"helukabel-16-awg-7-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83686","title":"Helukabel 16 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83686","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83686\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83686.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 16 AWG 7 Cores Helukabel JZ-603, 83686\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 1,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e11,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e101,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e225,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83686\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133981114431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_0381006d-a10d-4794-ab14-04f77188105d.jpg?v=1571726576"},{"product_id":"helukabel-18-awg-12-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83676","title":"Helukabel 18 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83676","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83676\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83676.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 12 Cores Helukabel JZ-603, 83676\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e12,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e115,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e285,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83676\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134006378559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_108131a7-87e6-4846-a512-989b0b5f1ddd.jpg?v=1571726599"},{"product_id":"helukabel-18-awg-18-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83677","title":"Helukabel 18 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83677","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83677\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83677.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 18 Cores Helukabel JZ-603, 83677\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e14,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e173,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e405,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83677\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134016667711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_fcef3126-b1ff-4c1a-bc13-d1cc8eb46e02.jpg?v=1571726618"},{"product_id":"helukabel-18-awg-2-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83706","title":"Helukabel 18 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83706","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83706\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83706.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 2 Cores Helukabel JZ-603, 83706\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e19,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e70,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83706\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134175625279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_19b63e89-c892-4bb8-8157-170028d1ef73.jpg?v=1571726621"},{"product_id":"helukabel-18-awg-25-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83678","title":"Helukabel 18 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83678","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83678\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83678.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 25 Cores Helukabel JZ-603, 83678\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e18,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e240,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e570,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83678\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134195253311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_dcbebdcb-c12c-4d41-85c4-d4228df94a7a.jpg?v=1571726624"},{"product_id":"helukabel-18-awg-3-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83672","title":"Helukabel 18 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83672","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83672\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83672.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 3 Cores Helukabel JZ-603, 83672\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e29,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e88,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83672\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134213898303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_4c6492b7-25e4-404f-ab2e-57ada0d5d28a.jpg?v=1571726628"},{"product_id":"helukabel-18-awg-34-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83679","title":"Helukabel 18 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83679","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83679\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83679.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 34 Cores Helukabel JZ-603, 83679\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e34 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e20,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e326,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e742,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83679\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134232870975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_714710d9-47dc-43ff-a1a3-7def57d3d4e5.jpg?v=1571726631"},{"product_id":"helukabel-18-awg-4-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83673","title":"Helukabel 18 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83673","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83673\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83673.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 4 Cores Helukabel JZ-603, 83673\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e39,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e99,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83673\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134245781567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_a6d33c7a-0127-46bd-b75b-d8718a4daf07.jpg?v=1571726645"},{"product_id":"helukabel-18-awg-41-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83680","title":"Helukabel 18 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83680","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83680\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83680.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 41 Cores Helukabel JZ-603, 83680\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e41 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e22,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e394,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e885,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83680\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134262198335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_11e2447a-786e-423a-b480-4e3bb1e833b7.jpg?v=1571726648"},{"product_id":"helukabel-18-awg-5-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83674","title":"Helukabel 18 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83674","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83674\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83674.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 5 Cores Helukabel JZ-603, 83674\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e48,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e132,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83674\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134273994815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_e6f529c2-5e5f-4539-b58e-c9e5f3a331a7.jpg?v=1571726650"},{"product_id":"helukabel-18-awg-50-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83681","title":"Helukabel 18 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83681","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83681\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83681.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 50 Cores Helukabel JZ-603, 83681\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e50 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e24,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e480,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1071,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83681\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134282580031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_281370dd-1a5b-4caa-8482-b397aced865b.jpg?v=1571726652"},{"product_id":"helukabel-18-awg-61-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83682","title":"Helukabel 18 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83682","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83682\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83682.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 61 Cores Helukabel JZ-603, 83682\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e60 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e26,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e586,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1265,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83682\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134291853375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_df691961-4679-420b-918f-3b7a29b98759.jpg?v=1571726654"},{"product_id":"helukabel-18-awg-7-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83675","title":"Helukabel 18 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83675","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83675\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83675.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 18 AWG 7 Cores Helukabel JZ-603, 83675\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 1 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e10,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e67,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e170,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83675\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134300274751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_1c724900-093c-4e54-8a5d-5c11efb3d922.jpg?v=1571726656"},{"product_id":"helukabel-19-awg-12-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83665","title":"Helukabel 19 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83665","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83665\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83665.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 12 Cores Helukabel JZ-603, 83665\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e11,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e86,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e245,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83665\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134327930943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_99425f08-e9b0-440c-b978-897f5aaa018c.jpg?v=1571726678"},{"product_id":"helukabel-19-awg-18-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83666","title":"Helukabel 19 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83666","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83666\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83666.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 18 Cores Helukabel JZ-603, 83666\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e13,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e130,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e327,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83666\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134342021183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_b4827c8a-91c3-4a32-84f3-0707e9033c84.jpg?v=1571726681"},{"product_id":"helukabel-19-awg-2-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83705","title":"Helukabel 19 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83705","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83705\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83705.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 2 Cores Helukabel JZ-603, 83705\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e14,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e66,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83705\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134351556671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_fa4fc869-3fac-4eb0-baa3-b6dadbb88eb1.jpg?v=1571726686"},{"product_id":"helukabel-19-awg-25-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83667","title":"Helukabel 19 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83667","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83667\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 25 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83667.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 25 Cores Helukabel JZ-603, 83667\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e17,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e180,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e466,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83667\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134373642303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_d6566e68-003a-49c2-8c0d-880dad97c7a5.jpg?v=1571726690"},{"product_id":"helukabel-19-awg-3-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83661","title":"Helukabel 19 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83661","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83661\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 3 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83661.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 3 Cores Helukabel JZ-603, 83661\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e22,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e76,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83661\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134389207103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_24081785-4b44-4ccf-b6fd-0aee510b550d.jpg?v=1571726693"},{"product_id":"helukabel-19-awg-34-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83668","title":"Helukabel 19 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83668","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83668\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 34 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83668.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 34 Cores Helukabel JZ-603, 83668\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e34 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e19,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e245,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e626,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83668\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134404771903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_b4f9f7ac-47c8-4e0f-a24f-bf2e01edec04.jpg?v=1571726696"},{"product_id":"helukabel-19-awg-4-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83662","title":"Helukabel 19 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83662","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83662\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 4 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83662.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 4 Cores Helukabel JZ-603, 83662\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e29,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e85,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83662\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134413422655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_1410922d-e737-426a-a36b-7325f697c04b.jpg?v=1571726717"},{"product_id":"helukabel-19-awg-41-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83669","title":"Helukabel 19 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83669","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83669\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 41 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83669.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 41 Cores Helukabel JZ-603, 83669\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e41 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e20,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e296,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e747,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83669\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134422597695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_e4b3fa54-8032-42f2-b911-0c65ec975fdd.jpg?v=1571726720"},{"product_id":"helukabel-19-awg-5-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83663","title":"Helukabel 19 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83663","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83663\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 5 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83663.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 5 Cores Helukabel JZ-603, 83663\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e36,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e113,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83663\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134429347903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_de66b578-f07c-4a34-83f8-b30e52711c85.jpg?v=1571726722"},{"product_id":"helukabel-19-awg-50-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83670","title":"Helukabel 19 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83670","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83670\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 50 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83670.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 50 Cores Helukabel JZ-603, 83670\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e50 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e23,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e360,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e896,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83670\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134440259647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_2443169e-798c-48a7-88cc-933e6ba80f14.jpg?v=1571726724"},{"product_id":"helukabel-19-awg-61-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83671","title":"Helukabel 19 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83671","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83671\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 61 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83671.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 61 Cores Helukabel JZ-603, 83671\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e61 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e25,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e439,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1070,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83671\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134444355647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_ba89c0b8-c6bf-4c4e-859d-b2a64c5306ee.jpg?v=1571726726"},{"product_id":"helukabel-19-awg-7-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83664","title":"Helukabel 19 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83664","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83664\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 7 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83664.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 19 AWG 7 Cores Helukabel JZ-603, 83664\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 0,75 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e9,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e50,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e144,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83664\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134450188351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_e255111e-a21d-45c2-870e-25d63064a21c.jpg?v=1571726728"},{"product_id":"helukabel-20-awg-12-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83654","title":"Helukabel 20 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83654","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83654\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 12 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83654.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 20 AWG 12 Cores Helukabel JZ-603, 83654\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 0,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e11,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e58,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e198,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83654\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134497407039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_ec23a21c-0e34-4691-aaa4-cb905fa0918e.jpg?v=1571726774"},{"product_id":"helukabel-20-awg-18-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83655","title":"Helukabel 20 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83655","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83655\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 18 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83655.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 20 AWG 18 Cores Helukabel JZ-603, 83655\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 0,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e12,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e86,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e266,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83655\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134510547007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_2a006761-8e7b-41f1-825d-3e66ac2d0bac.jpg?v=1571726779"},{"product_id":"helukabel-20-awg-2-cores-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable-83704","title":"Helukabel 20 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83704","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83704\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 2 Cores JZ-603 Multi Approval Control Cable Oil Resistant Meter Marking Cable 83704.Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Price, Helukabel Quote, Helukabel JZ-603, Helukabel JZ-603 Price, Helukabel JZ-603 Quote, Control Cable, Control Cable Price, Control Cable qutoe, Oil Resistant Cable, Oil Resistant Cable Price, Oil Resistant Cable Quote, 20 AWG 2 Cores Helukabel JZ-603, 83704\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e\n        • Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51\/ DIN EN 50525-2-51 and UL Style 2587\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e\n        • HAR\u003cbr\u003e\n        • flexing -5°C to +70°C\u003cbr\u003e\n        • fixed installation -40°C to +70°C\u003cbr\u003e\n        • UL\/CSA\u003cbr\u003e\n        • flexing -5°C to +90°C\u003cbr\u003e\n        • fixed installation -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e\n        • HAR U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e\n        • min. 6000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e\n        • up to 80x10\u003csup\u003e6\u003c\/sup\u003e cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of oil resistant special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        • G = with GN-YE conductor\u003cbr\u003e\n        • x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²\u003cbr\u003e\n        • Screened analogue type: JZ-603-CY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        • UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry, moist and wet rooms but not for open air.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 0,5 \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø\n                    app. mm\u003c\/td\u003e\n                    \u003ctd\u003e5,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop.\n                    weight\n                    kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e9,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight\n                    app.\n                    kg\/km\n                    \u003c\/td\u003e\n                    \u003ctd\u003e52,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e83704\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7147935268927,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-603_20Multi_20Approval_20Control_20Cable-lg_976ef264-5c10-4622-8c2a-0b48bbf0be25.jpg?v=1571726782"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/helukabel-jz-603-multi-approval-control-cable-oil-resistant-meter-marking-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}