{"title":"General Cable VNTC® Nylon PVC Type TC-ER1 Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"","products":[{"product_id":"vntc-nylon-pvc-type-tc-er1-10-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 10\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 10\/2 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 10\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243770* Click for a free quote.TC-ER1 10\/4 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 10\/2 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e177\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243770*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163845279807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_6b700b26-4dcb-4326-9290-86c0b01dd1bd.jpg?v=1571728346"},{"product_id":"vntc-nylon-pvc-type-tc-er1-10-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 10\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 10\/3 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 10\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243820* Click for a free quote.TC-ER1 10\/3 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 10\/3 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243820*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163845410879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_ff91998b-d660-4ea7-9266-946bf1321611.jpg?v=1571728346"},{"product_id":"vntc-nylon-pvc-type-tc-er1-10-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 10\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 10\/4 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 10\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243690* Click for a free quote.TC-ER1 10\/4 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\" TC-ER1 10\/4 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e12.70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243690*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163845574719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_d343b887-6b51-4c7c-8dfc-bcb7090eb67d.jpg?v=1571728346"},{"product_id":"vntc-nylon-pvc-type-tc-er1-12-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 12\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 12\/2 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 12\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243670 Click for a free quote.TC-ER1 12\/2 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 12\/2 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163846099007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_deaa13e3-59a3-4e9d-9d9d-0b4ff32242f0.jpg?v=1571728347"},{"product_id":"vntc-nylon-pvc-type-tc-er1-12-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 12\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 12\/3 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 12\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243810* Click for a free quote.TC-ER1 12\/3 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 12\/3 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.390\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243810*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163847802943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_6b6cf041-9b9e-4adb-838b-641cedb65d11.jpg?v=1571728347"},{"product_id":"vntc-nylon-pvc-type-tc-er1-12-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 12\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 12\/4 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 12\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243840 Click for a free quote.TC-ER1 12\/4 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 12\/4 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e139\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163849900095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_671fada9-e24e-4195-bb67-52836e67bde1.jpg?v=1571728347"},{"product_id":"vntc-nylon-pvc-type-tc-er1-14-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 14\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 14\/2 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 14\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243660 Click for a free quote.TC-ER1 14\/2 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 14\/2 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e8.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163853701183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_4c6d715d-3b68-4496-a58e-52550675ca27.jpg?v=1571728347"},{"product_id":"vntc-nylon-pvc-type-tc-er1-14-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 14\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 14\/3 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 14\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243720 Click for a free quote.TC-ER1 14\/3 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 14\/3 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e8.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163853930559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_94d57532-5188-4d71-9662-6aaf073652fd.jpg?v=1571728347"},{"product_id":"vntc-nylon-pvc-type-tc-er1-14-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 14\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 14\/4 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 14\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243650 Click for a free quote.TC-ER1 14\/4 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\" TC-ER1 14\/4 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163854127167,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_c97a447e-46fb-4269-b0c0-cf9b28b9ec8e.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-14-5-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 14\/5 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 14\/5 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 14\/5 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243570* Click for a free quote.TC-ER1 14\/5 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 14\/5 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e123\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243570*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163854258239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_24feaaa3-d445-42a7-aa18-33bef0783357.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-14-7-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 14\/7 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 14\/7 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 14\/7 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243580 Click for a free quote.TC-ER1 14\/7 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 14\/7 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163854389311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_1cf7cdcf-f12b-49b5-9b2a-687e00bfcb2b.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-16-12-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 16\/12 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 16\/12 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 16\/7 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-229600* Click for a free quote.TC-ER1 16\/7 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\" TC-ER1 16\/12 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e12.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e149\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e229600*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163854651455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_e8e67950-c419-44de-a85d-aad0e90e4ded.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-16-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 16\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 16\/2 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 16\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-247620 Click for a free quote.TC-ER1 16\/2 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 16\/2 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e7.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e247620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163855536191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_43806fa6-97fa-4892-b2ed-c81166a8fcf3.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-16-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 16\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 16\/3 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 16\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-261160 Click for a free quote.TC-ER1 16\/3 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 16\/3 Gauge , vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e8.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e261160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163855634495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_884fc4e9-fbb3-4573-93ca-2e8eaeff8462.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-16-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 16\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 16\/4 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 16\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243710 Click for a free quote.TC-ER1 16\/4 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 16\/4 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e8.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163855896639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_bdfd7e1f-f7d4-461c-a9b1-87668e054a3c.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-16-5-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 16\/5 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 16\/5 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 16\/5 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-266580* Click for a free quote.TC-ER1 16\/5 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 16\/5 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e266580*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163856027711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_c4c6895f-b327-49cf-ab9c-f9fa750e672b.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-16-7-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 16\/7 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 16\/7 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 16\/7 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243740* Click for a free quote.TC-ER1 16\/7 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 16\/7 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e177\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243740*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163856093247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_a5ae25e6-8230-4fed-8827-43e9f3d133ed.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-16-9-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 16\/9 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 16\/9 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 16\/7 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-243560* Click for a free quote.TC-ER1 16\/7 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 16\/9 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e243560*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163856224319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_0a5dbaad-f176-4222-8dd0-3c3fde6a2a43.jpg?v=1571728348"},{"product_id":"vntc-nylon-pvc-type-tc-er1-18-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 18\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC Nylon PVC Type TC-ER1 18\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 18\/2 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-261130 Click for a free quote.TC-ER1 18\/2 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\" TC-ER1 18\/2 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e7.11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e261130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163856781375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_39f8faac-b7f4-4261-8b18-59e110e30fd0.jpg?v=1571728349"},{"product_id":"vntc-nylon-pvc-type-tc-er1-18-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 18\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 18\/3 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 18\/3 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-261140 Click for a free quote.TC-ER1 18\/3 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 18\/3 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e7.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e261140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163858092095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_b3717865-fdeb-4513-8ab5-adb0ccccd84c.jpg?v=1571728349"},{"product_id":"vntc-nylon-pvc-type-tc-er1-18-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 18\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 18\/4 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 18\/4 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-261150 Click for a free quote.TC-ER1 18\/4 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 18\/4 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e7.87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e261150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163860385855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_632d6daf-eece-4176-8627-c8568bae4062.jpg?v=1571728349"},{"product_id":"vntc-nylon-pvc-type-tc-er1-18-5-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 18\/5 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 18\/5 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 18\/5 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-260000* Click for a free quote.TC-ER1 18\/5 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 18\/5 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e8.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e260000*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163860451391,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_73cc5461-9063-43c9-922e-14e9e92459b1.jpg?v=1571728349"},{"product_id":"vntc-nylon-pvc-type-tc-er1-18-7-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 18\/7 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC NYLON PVC TYPE TC-ER1 18\/7 GAUGE OVERALL SHIELDED E-2 COLOR CODE CONTROL SHIELDED 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 18\/7 Gauge Overall Shielded E-2 Color Code Control Shielded 600V UL-259980* Click for a free quote.TC-ER1 18\/7 Gauge 7W  stranding.\"\u003e\u003cmeta name=\"Keywords\" content=\"TC-ER1 18\/7 Gauge, vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e259980*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163860582463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_5f6e94de-d454-443a-9694-38772a675262.jpg?v=1571728349"},{"product_id":"vntc-nylon-pvc-type-tc-er1-overall-shielded-e-2-color-code-control-shielded-600v-ul","title":"General Cable VNTC® Nylon PVC Type TC-ER1 Overall Shielded E-2 Color Code Control Shielded 600V UL","description":"VNTC Nylon PVC Type TC-ER1 Overall Shielded E-2 Color Code Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  VNTC Nylon PVC Type TC-ER1 Overall Shielded E-2 Color Code Control Shielded 600V UL Click for a free quote.        \"\u003e\u003cmeta name=\"Keywords\" content=\"vntc cable, vntc tray cable, vntc cable quote, vntc cable price, vntc wire, tray cable, vntc tray cable, tc cable, tc er cable, type tc cable, er1 cable, PVC cable, PVC wire, Type TC-ER1 wire, Type TC-ER1 cable, , Type TC-ER1 cable quote,  Type TC-ER1 cable price, Shielded wire, Shielded cable price, Shielded cable , Shielded cable quote, Shielded 600V cable, Shielded 600V wire, Shielded 600V cable quote, Shielded 600V cable price, 600V cable, 600V wire, ul approved cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Flame-retardant Polyvinyl Chloride (PVC) with Polyamide (nylon)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 plus alpha-numeric printed numbers (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer, in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceways and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Approved for direct burial\u003cbr\u003e • Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C dry, 75?C wet\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Provides outstanding sunlight, cold bend and cold impact resistance\u003cbr\u003e • Offers the smallest cable O.D. available for suitable applications\u003cbr\u003e • Provides long service life\u003cbr\u003e • Provides good oil and chemical resistance\u003cbr\u003e • Meets cold bend test at -25?C\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179\u003cbr\u003e • UL 1581\u003cbr\u003e • UL 66 NEC Type TFN conductors (16 \u0026amp; 18 AWG)\u003cbr\u003e • UL 83 NEC Type THHN\/THWN conductors (14 through 10 AWG)\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 383\u003cbr\u003e • IEEE 1202\u003cbr\u003e • CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable style=\"width: 542px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 122px;\"\u003econd. Size (AWG\/kcmil)\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 62px;\"\u003eNo. of cond.\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 119px;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 124px;\"\u003eGeneral cable part number\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 77px;\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd style=\"color: #ffffff; width: 76px;\"\u003eLbs\/1000Ft\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff; width: 43px;\"\u003eKg\/Km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" style=\"width: 504px;\"\u003e18 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e18\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e40\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e60\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e261130\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-18-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e18\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e49\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e73\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e261140\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-18-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e18\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e58\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e86\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e261150\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-18-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e18\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e70\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e104\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e260000*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-18-5-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e18\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e89\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e132\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e259980*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-18-7-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" style=\"width: 504px;\"\u003e16 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e52\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e77\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e247620\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-16-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e63\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e94\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e261160\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-16-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e77\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e115\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243710\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-16-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e91\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e135\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e266580*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-16-5-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e119\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e177\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243740*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-16-7-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e9\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e150\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e223\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243560*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-16-9-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e185\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e275\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e229600*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-16-12-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" style=\"width: 504px;\"\u003e14 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e14\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e67\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e100\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243660\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-14-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e14\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e84\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e125\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243720\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-14-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e14\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e104\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e155\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243650\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-14-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e14\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e123\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e183\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243570*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-14-5-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e14\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e161\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e240\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243580\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-14-7-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" style=\"width: 504px;\"\u003e12 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e83\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e124\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243670\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-12-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e111\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e165\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243810*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-12-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e139\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e207\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243840\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-12-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" style=\"width: 504px;\"\u003e10 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e119\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e177\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243770*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-10-2-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e162\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e241\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243820*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-10-3-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 122px;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"width: 62px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 76px;\"\u003e205\u003c\/td\u003e\n\u003ctd style=\"width: 43px;\"\u003e305\u003c\/td\u003e\n\u003ctd style=\"width: 124px;\"\u003e243690*\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/vntc-nylon-pvc-type-tc-er1-10-4-gauge-overall-shielded-e-2-color-code-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163865366591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_03b2b8f6-5470-4ac9-9999-3edbd4ad4fff.jpg?v=1571728350"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/01_adb91885-0805-4e8b-943f-d785d4aa297b.jpg?v=1524289976","url":"https:\/\/nassauelectricalspot.com\/collections\/general-cable-vntc%c2%ae-nylon-pvc-type-tc-er1-overall-shielded-e-2-color-code-control-shielded-600v-ul.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}