{"title":"General Cable NextGen® Tight Buffer Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"","products":[{"product_id":"nextgen-tight-buffer-12-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 12 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 12 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy our Product NextGen Tight Buffer 12 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 12 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature:  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)\u003c\/span\u003e\u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e1423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0121PNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152398925887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_de1f0f75-9a1c-406e-a5f7-121e70155f9f.jpg?v=1571727495"},{"product_id":"nextgen-tight-buffer-120-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 120 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 120 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 120 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 120 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature: \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e374\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e556\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e6672\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e2224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX1201P1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152399024191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_0a385616-b75a-4f17-9737-6b69cb88252c.jpg?v=1571727495"},{"product_id":"nextgen-tight-buffer-144-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 144 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 144 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 144 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 144 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature: \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e6672\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e2224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX1441P1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152399188031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_86d44039-1ab6-455b-b5a0-4f58e1946108.jpg?v=1571727495"},{"product_id":"nextgen-tight-buffer-18-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 18 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 18 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 18 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 18 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature:  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)\u003c\/span\u003e\u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e1423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0181PNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152399351871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_e3dc895f-4e4b-480d-8680-354454c07ae2.jpg?v=1571727495"},{"product_id":"nextgen-tight-buffer-2-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 2 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 2 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 2 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 2 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature:  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)\u003c\/span\u003e \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0021PNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152399581247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_bdeba8b0-417d-483c-9f37-78fba04050bb.jpg?v=1571727495"},{"product_id":"nextgen-tight-buffer-24-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 24 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 24 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 24 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 24 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature:  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)\u003c\/span\u003e \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e1423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0241PNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152400793663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_d32b9481-8c84-4c8c-90bd-e186338dad64.jpg?v=1571727495"},{"product_id":"nextgen-tight-buffer-36-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 36 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 36 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 36 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 36 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40\u003cspan\u003e°\u003c\/span\u003eF) to +70\u003cspan\u003e°\u003c\/span\u003eC (+158\u003cspan\u003e°\u003c\/span\u003eF) \u003cbr\u003e      Installation 0\u003cspan\u003e°\u003c\/span\u003eC (+32\u003cspan\u003e°\u003c\/span\u003eF) to +50\u003cspan\u003e°\u003c\/span\u003eC (+122\u003cspan\u003e°\u003c\/span\u003eF) \u003cbr\u003e      Operating -20\u003cspan\u003e°\u003c\/span\u003eC (-4\u003cspan\u003e°\u003c\/span\u003eF) to +70\u003cspan\u003e°\u003c\/span\u003eC (+158\u003cspan\u003e°\u003c\/span\u003eF) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e4448\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e1490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0361P1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152402497599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_d2d33434-333f-4607-a36a-e3114115f357.jpg?v=1571727496"},{"product_id":"nextgen-tight-buffer-4-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 4 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 4 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 4 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 4 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature:  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)\u003c\/span\u003e \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0041PNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152402661439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_48f8bdf5-2643-4645-9a9c-19b9213b4899.jpg?v=1571727496"},{"product_id":"nextgen-tight-buffer-48-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 48 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 48 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 48 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 48 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature: \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e4448\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e1490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0481P1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152402923583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_3d182e0e-3716-4a44-b486-bc90e904f090.jpg?v=1571727496"},{"product_id":"nextgen-tight-buffer-6-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 6 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 6 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 6 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 6 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature:  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)\u003c\/span\u003e \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0061PNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152403218495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_6571a924-ec88-4824-8d6c-0921456ee67c.jpg?v=1571727496"},{"product_id":"nextgen-tight-buffer-60-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 60 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 60 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 60 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 60 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature: \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e4448\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e1490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0601P1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152403316799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_3d71b4af-406a-470a-a5d7-60e942ad92e1.jpg?v=1571727496"},{"product_id":"nextgen-tight-buffer-72-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 72 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 72 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 72 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 72 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature: \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e4448\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e1490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0721P1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152403546175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_6251b15b-5beb-437a-a552-5d61ee381243.jpg?v=1571727496"},{"product_id":"nextgen-tight-buffer-8-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 8 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 8 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 8 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 8 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature:  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF)\u003c\/span\u003e\u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e1090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0081PNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152405119039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_f9d391ba-66b3-4646-a7c6-8d10394775d2.jpg?v=1571727496"},{"product_id":"nextgen-tight-buffer-96-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer 96 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"NextGen Tight Buffer 96 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen Tight Buffer 96 Fiber Count Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen Tight Buffer 96 Fiber Count,Type OFNP CSA FT6, Fiber Optic Cable, Indoor Fiber Optic Cable, Plenum Indoor Fiber Optic Cable, NextGen, Tight Buffer Distribution Plenum, Type OFNP Cable, CSA FT6,\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–144 fibers \u003cbr\u003e • 900 μm tight buffer \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant compound or fluoropolymer \u003cbr\u003e • Sequential footage markings* \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps) \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Lightweight, flexible design simplifies installation \u003cbr\u003e • Tight buffer provides individual fiber protection \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e\u003cspan\u003e• Temperature: \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Storage -40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-40\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Installation 0\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+32\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +50\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+122\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e     Operating -20\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (-4\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) to +70\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eC (+158\u003c\/span\u003e\u003cspan\u003e°\u003c\/span\u003e\u003cspan\u003eF) \u003c\/span\u003e\u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm) \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Intrabuilding voice or data communication backbones \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • ETL Listed Type OFNP \u003cbr\u003e • CSA FT6 \u003cbr\u003e • TIA 568 C.3 \u003cbr\u003e • ICEA S-83-596 \u003cbr\u003e • GR-409 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of sub-units\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e464\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e6672\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e2224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0961P1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152406364223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_0e7c6497-af3f-4c40-acea-65dbc43a03ef.jpg?v=1571727496"},{"product_id":"nextgen-tight-buffer-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6","title":"General Cable NextGen® Tight Buffer Distribution Plenum Indoor Fiber Optic Cable Type OFNP CSA FT6","description":"\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e  \u003cbr\u003e • 2–144 fibers  \u003cbr\u003e • 900 \u003cspan\u003eμ\u003c\/span\u003em tight buffer  \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member:\u003c\/strong\u003e Epoxy\/glass rod (P1D) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Strength Member:\u003c\/strong\u003e Aramid fiber yarn \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e \u003cbr\u003e • Flame-retardant compound or fluoropolymer  \u003cbr\u003e • Sequential footage markings*  \u003cbr\u003e • Orange jacket—multimode fibers (except 10 Gbps)  \u003cbr\u003e • Aqua jacket—10 Gbps multimode fibers  \u003cbr\u003e • Yellow jacket—singlemode fibers \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e \u003cbr\u003e • Lightweight, flexible design simplifies installation  \u003cbr\u003e • Tight buffer provides individual fiber protection  \u003cbr\u003e • Tight buffered fibers are easy to handle and strip for field connectorization  \u003cbr\u003e • Sub-units are numbered for identification \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e  \u003cbr\u003e • Temperature:  \u003cbr\u003e      Storage -40°C (-40\u003cspan\u003e°\u003c\/span\u003eF) to +70\u003cspan\u003e°\u003c\/span\u003eC (+158\u003cspan\u003e°\u003c\/span\u003eF)  \u003cbr\u003e      Installation 0\u003cspan\u003e°\u003c\/span\u003eC (+32\u003cspan\u003e°\u003c\/span\u003eF) to +50\u003cspan\u003e°\u003c\/span\u003eC (+122\u003cspan\u003e°\u003c\/span\u003eF)  \u003cbr\u003e      Operating -20\u003cspan\u003e°\u003c\/span\u003eC (-4\u003cspan\u003e°\u003c\/span\u003eF) to +70\u003cspan\u003e°\u003c\/span\u003eC (+158\u003cspan\u003e°\u003c\/span\u003eF)  \u003cbr\u003e • Minimum Bend Radius:  \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD—In-Service  \u003cbr\u003e • Maximum Crush Resistance: 850 lbs\/in (1485 N\/cm)  \u003cbr\u003e • Maximum Vertical Rise—1,640 ft (500 m) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e  \u003cbr\u003e • Intrabuilding voice or data communication backbones  \u003cbr\u003e • ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article 770.154 and 770.179 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e \u003cbr\u003e • ETL Listed Type OFNP  \u003cbr\u003e • CSA FT6  \u003cbr\u003e • TIA 568 C.3  \u003cbr\u003e • ICEA S-83-596  \u003cbr\u003e • GR-409  \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOption: \u003c\/strong\u003eRipcord available on PNUs, comes as standard on P1Ds\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003eno.of loose tubes\u003c\/td\u003e\n\u003ctd\u003emaximum tensile load \u003cbr\u003e in-service N\u003c\/td\u003e\n\u003ctd\u003egeneral cable and nextgen \u003cbr\u003e brand part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003exx0021pnu\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-2-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003exx0041pnu\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-4-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003exx0061pnu\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-6-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e311\u003c\/td\u003e\n\u003ctd\u003exx0081pnu\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-8-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003exx0121pnu\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-12-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003exx0181pnu\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-18-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003exx0241pnu\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-24-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e1490\u003c\/td\u003e\n\u003ctd\u003exx0361p1d\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-36-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e1490\u003c\/td\u003e\n\u003ctd\u003exx0481p1d\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-48-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e1490\u003c\/td\u003e\n\u003ctd\u003exx0601p1d\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-60-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e1490\u003c\/td\u003e\n\u003ctd\u003exx0601p1d\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-72-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2224\u003c\/td\u003e\n\u003ctd\u003exx0961p1d\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-96-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2224\u003c\/td\u003e\n\u003ctd\u003exx1201p1d\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-120-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2224\u003c\/td\u003e\n\u003ctd\u003exx1441p1d\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/indoor-outdoor-cables\/nextgen-tight-buffer-144-fiber-count-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152407314495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_9b9c631c-80a2-4de8-9650-f51056490e7c.jpg?v=1571727497"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/general-cable-nextgen%c2%ae-tight-buffer-distribution-plenum-indoor-fiber-optic-cable-type-ofnp-csa-ft6.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}