{"title":"General Cable NextGen® Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"","products":[{"product_id":"nextgen-108-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 108 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 108 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 108 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 108 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX10841M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152374022207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_7f02e413-7ad7-474f-90b1-c9166c62831e.jpg?v=1571727465"},{"product_id":"nextgen-12-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 12 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 12 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 12 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 12 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0124M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152374349887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_3c92519c-81ae-42be-911a-1f3646373eb9.jpg?v=1571727465"},{"product_id":"nextgen-120-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 120 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 120 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 120 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 120 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX1204M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152375234623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_1f2720fe-1c2d-4c3a-94bd-883a1c7d11b5.jpg?v=1571727485"},{"product_id":"nextgen-144-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 144 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 144 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 144 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 144 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX1444M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152376053823,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_a48c4b5b-f047-4982-bfbb-ef0e467eb446.jpg?v=1571727485"},{"product_id":"nextgen-18-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 18 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 18 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 18 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 18 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0184M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152376610879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_3d6dbebd-4cc2-4d15-a132-a2a5ac3aa84f.jpg?v=1571727485"},{"product_id":"nextgen-192-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 192 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 192 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 192 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 192 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e179\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX1924M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152376938559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_b13818aa-79f4-497a-8524-7b6f0be4c12d.jpg?v=1571727485"},{"product_id":"nextgen-216-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 216 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 216 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 216 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 216 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e179\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX2164M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152377626687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_449b28e9-9df2-4e5e-96e3-18ec3844d5b0.jpg?v=1571727486"},{"product_id":"nextgen-24-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 24 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 24 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 24 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 24 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0244M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152378282047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_445389da-da76-44db-ae86-29fcf1c02616.jpg?v=1571727486"},{"product_id":"nextgen-240-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 240 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 240 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 240 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 240 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e17.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX2404M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152378839103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_e7859d04-8490-41c3-af45-0bfb2bff8e7b.jpg?v=1571727487"},{"product_id":"nextgen-264-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 264 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 264 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 264 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 264 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e17.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX2644M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152379363391,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_49f84681-beb8-483c-8701-fad667feb387.jpg?v=1571727487"},{"product_id":"nextgen-288-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 288 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 288 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 288 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 288 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e18.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX2884M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152379494463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_8c0590bf-f6db-4662-a7df-8b4ecbd88424.jpg?v=1571727487"},{"product_id":"nextgen-312-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 312 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 312 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 312 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 312 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e20.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX3124M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152379691071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_1a5d6665-9970-4837-a134-8f44c63fabab.jpg?v=1571727487"},{"product_id":"nextgen-36-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 36 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 36 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 36 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 36 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0364M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152380084287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_45e7d6d9-24a5-4193-bf60-b26e195def26.jpg?v=1571727487"},{"product_id":"nextgen-4-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 4 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 4 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 4 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 4 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0044M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152380837951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_300c09f1-2dd6-4f76-93bd-3ce29c2dd968.jpg?v=1571727488"},{"product_id":"nextgen-48-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 48 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 48 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 48 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 48 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0484M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152382771263,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_cba86a60-b664-46dd-954a-a58d4a1f6987.jpg?v=1571727488"},{"product_id":"nextgen-6-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 6 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 4 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 4 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 6 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0064M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152384606271,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_f8655aab-1bdc-4d8c-be7c-dca4e15db960.jpg?v=1571727489"},{"product_id":"nextgen-60-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 60 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 60 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 60 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 60 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0604M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152385818687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_2e660cd6-98fb-479b-8c4f-1e15df2413e4.jpg?v=1571727489"},{"product_id":"nextgen-72-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 72 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 72 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 72 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 72 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0724M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152386834495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_51528320-dc0c-4624-b9a1-7c34abd1013b.jpg?v=1571727490"},{"product_id":"nextgen-8-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 8 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 8 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 8 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 8 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0084M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152388309055,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_cc0d0311-76ed-4a41-921c-b5ed3e4d68ea.jpg?v=1571727490"},{"product_id":"nextgen-96-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 96 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"NextGen 96 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy Our Product NextGen 96 Fiber Count Loose Tube Single Jacket Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen 96 Fiber Count, Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e12.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(installation in n)\u003c\/td\u003e\n\u003ctd\u003e2700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in lbs)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load(in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0964M1A-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152389324863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_60099f94-5728-475e-8678-7bc459a0bd83.jpg?v=1571727491"},{"product_id":"nextgen-loose-tube-single-jacket-outside-plant-fiber-optic-cable","title":"General Cable NextGen® Loose Tube Single Jacket Outside Plant Fiber Optic Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our Product Loose Tube Single Jacket Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"Fiber Optic Cable, Outside Plant Fiber Optic Cable, NextGen Loose Tube, Single Jacket, Loose Tube Single Jacket, Loose Tube Cable, Single Jacket Outside Plant Fiber Optic Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 4–432 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e \u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings* \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance: \u003c\/strong\u003e\u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation  \u003cbr\u003e      10 X OD— In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduit or aerial\/lashed \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1A-DT) \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003eno. of loose tubes\u003c\/td\u003e\n\u003ctd\u003eMaximum Tensile Load\u003c\/td\u003e\n\u003ctd\u003eGeneral Cable And Nextgen \u003cbr\u003eBrand Part Number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-4-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0044m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-4-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-6-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0064m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-6-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-8-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0084m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-8-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-12-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0124m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-12-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-18-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0184m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-18-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-24-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e24\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0244m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-24-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-36-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e36\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0364m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-36-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-48-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e48\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0484m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-48-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-60-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e60\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0604m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-60-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-72-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e72\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0724m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-72-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-96-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e96\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0964m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-96-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-108-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e108\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx10841m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-108-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-120-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e120\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx1204m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-120-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-144-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e144\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx1444m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-144-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-192-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e192\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx1924m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-192-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-216-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e216\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx2164m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-216-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-240-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e240\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx2404m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-240-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-264-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e264\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx2644m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-264-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-288-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e288\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx2884m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-288-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-312-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003e312\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx3124m1a-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-312-fiber-count-loose-tube-single-jacket-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152396337215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_3c0347bd-63ed-48a5-8b52-821e7f24160b.jpg?v=1571727494"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/general-cable-nextgen%c2%ae-loose-tube-single-jacket-outside-plant-fiber-optic-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}