{"title":"General Cable EmPowr® CDC Underground Distribution Primary Combined Duct and Cable Primary Cable Installed in Polyethylene Duct","description":"","products":[{"product_id":"empowr-1-1-2-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-installed-in-polyethylene-duct","title":"General Cable EmPowr® 1 1\/2 Inches CDC Underground Distribution Primary Combined Duct and Cable Primary Cable Installed in Polyethylene Duct","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Assembly\u003c\/strong\u003e: EmPowr® CDC® Combined Duct \u0026amp; Cable consists of insulated conductor factory installed in a black high-density polyethylene conduit. The polyethylene conduit is extruded directly over any prior-made single medium-voltage cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: All underground distribution cables in EmPowr CDC are manufactured and tested in accordance with applicable industry standards and\/or individual customer specifications. See the appropriate catalog section for a complete cable description.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConduit\u003c\/strong\u003e: The high-density polyethylene EPEC-A Conduit is manufactured and tested in accordance with NEMA Standard TC7, “Smooth-wall Coilable Electrical Polyethylene Conduit.”\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr CDC Combined Duct \u0026amp; Cable offers an economical alternative to pulling cable in previously installed short lengths of duct joined with sleeve couplings. The inherent construction advantages and versatility of the EmPowr CDC design are ideally suited for underground primary distribution systems up to 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e: In addition to the initial labor savings achieved from installation of cable and conduit in a single operation, cable replacement costs and ground disruption are significantly less for the EmPowr CDC cable system. Tough, yet light and flexible, high-density polyethylene conduit provides ease of installation and high impact resistance for cable protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • EPEC-B, EPEC-40 or EPEC-80 smooth-wall coilable electrical polyethylene conduit TC7\u003cbr\u003e • Gray or red color\u003cbr\u003e • Extruded red stripes\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conduit size (inches)\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum i.d. (inches)\u003c\/td\u003e\n\u003ctd\u003e1.618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eo.d. (± 0.012\") (inches)\u003c\/td\u003e\n\u003ctd\u003e1.900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e2.056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (lb\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum* wall thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bend radius (inches)\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e2.056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum total cross-sectional area of conductors-53% fill one conductor (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e1.090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e1.618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum conductor diameter-one (1) conductor (inches)\u003c\/td\u003e\n\u003ctd\u003e1.178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129835798591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_dcda56c2-9c04-4654-b59d-c9e981057eb1.jpg?v=1571726256"},{"product_id":"empowr-1-1-4-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-installed-in-polyethylene-duct","title":"General Cable EmPowr® 1 1\/4 Inches CDC Underground Distribution Primary Combined Duct and Cable Primary Cable Installed in Polyethylene Duct","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\nconsists of insulated conductor factory installed in a black high-density polyethylene conduit. The polyethylene conduit is extruded directly over any prior-made single medium-voltage cable.\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: All underground distribution cables in EmPowr CDC are manufactured and tested in accordance with applicable industry standards and\/or individual customer specifications. See the appropriate catalog section for a complete cable description.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConduit\u003c\/strong\u003e: The high-density polyethylene EPEC-A Conduit is manufactured and tested in accordance with NEMA Standard TC7, “Smooth-wall Coilable Electrical Polyethylene Conduit.”\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr CDC Combined Duct \u0026amp; Cable offers an economical alternative to pulling cable in previously installed short lengths of duct joined with sleeve couplings. The inherent construction advantages and versatility of the EmPowr CDC design are ideally suited for underground primary distribution systems up to 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e: In addition to the initial labor savings achieved from installation of cable and conduit in a single operation, cable replacement costs and ground disruption are significantly less for the EmPowr CDC cable system. Tough, yet light and flexible, high-density polyethylene conduit provides ease of installation and high impact resistance for cable protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • EPEC-B, EPEC-40 or EPEC-80 smooth-wall coilable electrical polyethylene conduit TC7\u003cbr\u003e • Gray or red color\u003cbr\u003e • Extruded red stripes\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conduit size (inches)\u003c\/td\u003e\n\u003ctd\u003e1 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum i.d. (inches)\u003c\/td\u003e\n\u003ctd\u003e1.408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eo.d. (± 0.012\") (inches)\u003c\/td\u003e\n\u003ctd\u003e1.660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e1.557\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (lb\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum* wall thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bend radius (inches)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e1.557\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum total cross-sectional area of conductors-53% fill one conductor (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e0.825\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e1.408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum conductor diameter-one (1) conductor (inches)\u003c\/td\u003e\n\u003ctd\u003e1.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129835864127,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b3b1f7f4-7315-496a-bd70-abcdd5fe6979.jpg?v=1571726256"},{"product_id":"empowr-2-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-installed-in-polyethylene-duct","title":"General Cable EmPowr® 2 Inches CDC Underground Distribution Primary Combined Duct and Cable Primary Cable Installed in Polyethylene Duct","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Assembly\u003c\/strong\u003e: EmPowr® CDC® Combined Duct \u0026amp; Cable consists of insulated conductor factory installed in a black high-density polyethylene conduit. The polyethylene conduit is extruded directly over any prior-made single medium-voltage cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: All underground distribution cables in EmPowr CDC are manufactured and tested in accordance with applicable industry standards and\/or individual customer specifications. See the appropriate catalog section for a complete cable description.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConduit\u003c\/strong\u003e: The high-density polyethylene EPEC-A Conduit is manufactured and tested in accordance with NEMA Standard TC7, “Smooth-wall Coilable Electrical Polyethylene Conduit.”\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr CDC Combined Duct \u0026amp; Cable offers an economical alternative to pulling cable in previously installed short lengths of duct joined with sleeve couplings. The inherent construction advantages and versatility of the EmPowr CDC design are ideally suited for underground primary distribution systems up to 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e: In addition to the initial labor savings achieved from installation of cable and conduit in a single operation, cable replacement costs and ground disruption are significantly less for the EmPowr CDC cable system. Tough, yet light and flexible, high-density polyethylene conduit provides ease of installation and high impact resistance for cable protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • EPEC-B, EPEC-40 or EPEC-80 smooth-wall coilable electrical polyethylene conduit TC7\u003cbr\u003e • Gray or red color\u003cbr\u003e • Extruded red stripes\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conduit size (inches)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum i.d. (inches)\u003c\/td\u003e\n\u003ctd\u003e2.033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eo.d. (± 0.012\") (inches)\u003c\/td\u003e\n\u003ctd\u003e2.375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e3.246\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (lb\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum* wall thickness (inches)\u003c\/td\u003e\n\u003ctd\u003e0.145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum bend radius (inches)\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e3.246\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum total cross-sectional area of conductors-53% fill one conductor (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e1.720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum inside area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003e2.033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum conductor diameter-one (1) conductor (inches)\u003c\/td\u003e\n\u003ctd\u003e1.480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129864667199,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_12086074-c00f-4a6b-bac8-c2b5543a69db.jpg?v=1571726262"},{"product_id":"empowr-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-installed-in-polyethylene-duct","title":"General Cable EmPowr® CDC Underground Distribution Primary Combined Duct and Cable Primary Cable Installed in Polyethylene Duct","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Assembly\u003c\/strong\u003e: EmPowr® CDC® Combined Duct \u0026amp; Cable consists of insulated conductor factory installed in a black high-density polyethylene conduit. The polyethylene conduit is extruded directly over any prior-made single medium-voltage cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable\u003c\/strong\u003e: All underground distribution cables in EmPowr CDC are manufactured and tested in accordance with applicable industry standards and\/or individual customer specifications. See the appropriate catalog section for a complete cable description.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConduit\u003c\/strong\u003e: The high-density polyethylene EPEC-A Conduit is manufactured and tested in accordance with NEMA Standard TC7, “Smooth-wall Coilable Electrical Polyethylene Conduit.”\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: EmPowr CDC Combined Duct \u0026amp; Cable offers an economical alternative to pulling cable in previously installed short lengths of duct joined with sleeve couplings. The inherent construction advantages and versatility of the EmPowr CDC design are ideally suited for underground primary distribution systems up to 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e: In addition to the initial labor savings achieved from installation of cable and conduit in a single operation, cable replacement costs and ground disruption are significantly less for the EmPowr CDC cable system. Tough, yet light and flexible, high-density polyethylene conduit provides ease of installation and high impact resistance for cable protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e • EPEC-B, EPEC-40 or EPEC-80 smooth-wall coilable electrical polyethylene conduit TC7\u003cbr\u003e • Gray or red color\u003cbr\u003e • Extruded red stripes\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\" style=\"text-align: center;\"\u003eempowr cdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003enominal conduit\u003cbr\u003e size(inches)\u003c\/td\u003e\n\u003ctd\u003eminimum i.d.\u003cbr\u003e (inches)\u003c\/td\u003e\n\u003ctd\u003eo.d. (± 0.012\")\u003cbr\u003e (inches)\u003c\/td\u003e\n\u003ctd\u003emin. inside\u003cbr\u003e area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003eapprox. weight\u003cbr\u003e (lb\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003emin.* wall\u003cbr\u003e thickness (inches)\u003c\/td\u003e\n\u003ctd\u003emin. bend radius\u003cbr\u003e (inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-1-1-4-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-insta\"\u003e1 1\/4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.408\u003c\/td\u003e\n\u003ctd\u003e1.660\u003c\/td\u003e\n\u003ctd\u003e1.557\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e0.100\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-1-1-2-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-insta\"\u003e1 1\/2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.618\u003c\/td\u003e\n\u003ctd\u003e1.900\u003c\/td\u003e\n\u003ctd\u003e2.056\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003ctd\u003e0.115\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-2-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-installed\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.033\u003c\/td\u003e\n\u003ctd\u003e2.375\u003c\/td\u003e\n\u003ctd\u003e3.246\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003ctd\u003e0.145\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003emaximum cross-sectional area of conductors per conduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd rowspan=\"2\"\u003enominal conduit\u003cbr\u003e size (inches)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eminimum inside\u003cbr\u003e area (sq. inches)\u003c\/td\u003e\n\u003ctd\u003emaximum total cross-sectional\u003cbr\u003e area of conductors (sq. inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003e53% fill one conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-1-1-4-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-insta\"\u003e1 1\/4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.557\u003c\/td\u003e\n\u003ctd\u003e0.825\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-1-1-2-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-insta\"\u003e1 1\/2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.056\u003c\/td\u003e\n\u003ctd\u003e1.090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-2-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-installed\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3.246\u003c\/td\u003e\n\u003ctd\u003e1.720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003emaximum diameter of conductors per conduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd rowspan=\"2\"\u003enominal\u003cbr\u003e conduit\u003cbr\u003e size (inches)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eminimum\u003cbr\u003e inside area\u003cbr\u003e (sq. inches)\u003c\/td\u003e\n\u003ctd\u003emaximum conductor diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003eone (1) conductor (inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-1-1-4-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-insta\"\u003e1 1\/4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.408\u003c\/td\u003e\n\u003ctd\u003e1.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-1-1-2-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-insta\"\u003e1 1\/2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.618\u003c\/td\u003e\n\u003ctd\u003e1.178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/empowr-2-inches-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-installed\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.033\u003c\/td\u003e\n\u003ctd\u003e1.480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129968279615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_fb8959af-767e-4c87-93c9-015de3d4842a.jpg?v=1571726290"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/general-cable-empowr%c2%ae-cdc-underground-distribution-primary-combined-duct-and-cable-primary-cable-installed-in-polyethylene-duct.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}