{"title":"General Cable EmPowr® 35 kV Concentric Neutral Underground Distribution Cable Al Cond. 345 mils TRXLPE Insulation","description":"","products":[{"product_id":"empowr-1-0-awg-1-wire-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 1\/0 AWG 1 Wire 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129845039167,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_f831fc9b-9c3d-4272-aa67-5d5e5519a901.jpg?v=1571726258"},{"product_id":"empowr-1-0-awg-1-wire-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 1\/0 AWG 1 Wire 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE URD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.367\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e861\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(induct)\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129845203007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_4252bcb3-ac94-497c-951b-961d95e426c7.jpg?v=1571726258"},{"product_id":"empowr-1-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 1\/0 AWG 19 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e746\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129851723839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_abfcebcc-4d06-4647-ac93-1a45b4e0cbe8.jpg?v=1571726259"},{"product_id":"empowr-1-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 1\/0 AWG 19 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE URD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e891\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(induct)\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129851756607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b6108b56-bd5c-45fb-946e-5393d18ab522.jpg?v=1571726259"},{"product_id":"empowr-1000kcmil-61-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 1000kcmil 61 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.815\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e673\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e2925\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e595\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129854148671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_4691d9ef-db9b-4011-a66e-5e49a350ab9c.jpg?v=1571726260"},{"product_id":"empowr-2-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 2\/0 AWG 19 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e816\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129867616319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b4953308-50d5-4a5b-a75c-37f3c9341a21.jpg?v=1571726277"},{"product_id":"empowr-2-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 2\/0 AWG 19 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE URD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.448\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e267\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e996\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(induct)\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129867649087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_aeea405f-218a-46db-aa2a-a55e1d5007f0.jpg?v=1571726277"},{"product_id":"empowr-250kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 250kcmil 37 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e1106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129877610559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_eae05147-92a8-4546-919d-deeefddf3ca6.jpg?v=1571726279"},{"product_id":"empowr-3-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 3\/0 AWG 19 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e908\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129886490687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e636d7f5-6331-4959-94c1-78936a942811.jpg?v=1571726281"},{"product_id":"empowr-3-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 3\/0 AWG 19 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE URD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.532\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e1161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(induct)\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129886556223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e3af01f6-71f8-4102-9a8e-b1e940fabe82.jpg?v=1571726281"},{"product_id":"empowr-35-kv-concentric-neutral-underground-distribution-cable-al-cond-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 35 kV Concentric Neutral Underground Distribution Cable Al Cond. 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThis cable is made of Class B compressed and concentrically stranded aluminum 1350 conductors. Aluminum made cables are lightweight and flexible, they are shielded with an extruded polymeric semi-conductor that helps in stress control. The shielded conductors are then coated with an extruded lead-free TRXLPE (Tree-Retardant Cross-Linked Polyethylene) insulation that is also shielded. Concentric neutral made of bare annealed copper wire is bonded helically to the insulation shield.\u003c\/p\u003e\n\u003cp\u003eAnnealing is the process of making the copper wires soft and malleable.It is jacketed with a black linear low-density polyethylene compound which acts as a protection. It has a temperature operational rating of 90 to 250 degrees Celsius and voltage power rating of 35kV. EmPower 35kV power cable is tested and approved to meet the required international laboratory standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e \u003cbr\u003eEmPower 35kV cable is flexible and lightweight. This is because it is made of soft and malleable aluminum 1350 conductors. Flexible cables are easy to handle as you will use less effort in bending them as compared to rigid cables. Lightweight cables will relieve you from using excess unnecessary energy to lift them up especially during installation. You will agree with me thatthis EmPower 35kV power cable is an ideal cable of choice that stands a chance in your power lines given its flexibility attribute.\u003c\/p\u003e\n\u003cp\u003eThis cable is environmental friendly and is not prone to cause pollution. It is made of lead free products meaning that it releases less fumes in the environment in case of fire outbreak. EmPower 35kV cable offers an excellent resistant to water treeing due its protective TRXLPE insulation. The semi-conducting TRXLPE compound provides safety to the user against electrocution as well as keeping the cable safe from harsh environmental conditions.\u003c\/p\u003e\n\u003cp\u003eIt comes in three different temperature ratings making it a triple serving cable. It is rated at 90 degrees Celsius to serve in normal power lines, 130 degrees Celsius for emergency wiring systems and at 250 degrees Celsius for use in short circuits. EmPower 35kV cable is designed for use in three different locations.\u003c\/p\u003e\n\u003cp\u003eLinear Low-Density Polyethylene (LLDPE) jacketing is a tough outer layer that is black color coded for easy identification especially during installation. Color coding helps in preventing confusions that may occur. This semi-conducting jacketing LLDPE compound prevents the cable from corrosive chemicals, deformations, creeping, strong sunlight radiations and moisture. It offers a superb defense to the cable thus improving its electrical conductivity. I would recommend that you consider EmPower 35kV power cable and enjoy a long term power service in your wiring system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e \u003cbr\u003eDifferent power cables are designed with different power voltages, insulation and jacketing products to help suit their intended purposes. However, EmPower 35kV cable is meant to serve in either wet or dry conditions as a single or three-phase power distribution cable. Cables with having a full neutral calls for single-phase applications whereas cables with 1\/3 neutral are deployed in three-phase underground power lines. They are primarily installed through the duct system and direct burial.\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003eunderground distribution cable – 35 kv – type urd – full neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor\u003c\/td\u003e\n\u003ctd\u003ecopper neutral\u003c\/td\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft\u003c\/td\u003e\n\u003ctd\u003eampacity (2)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eal awg orkcmil\u003c\/td\u003e\n\u003ctd\u003ewire size awg\u003c\/td\u003e\n\u003ctd\u003etotal\u003c\/td\u003e\n\u003ctd\u003ein duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1-0-awg-1-wire-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345-m\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e861\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1-0-awg-1-wire-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345-m\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e891\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-2-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e996\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-2-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-3-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e1161\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-3-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-4-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e1318\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-4-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eunderground distribution cable – 35 kv – type ud – 1\/3 neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor\u003c\/td\u003e\n\u003ctd\u003ecopper neutral\u003c\/td\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft\u003c\/td\u003e\n\u003ctd\u003eampacity (3)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eal awg or kcmil\u003c\/td\u003e\n\u003ctd\u003ewire size awg\u003c\/td\u003e\n\u003ctd\u003etotal\u003c\/td\u003e\n\u003ctd\u003ein duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1-0-awg-1-wire-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mi\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e716\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1-0-awg-1-wire-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mi\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e746\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-2-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-3-1\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e816\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-2-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-3-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-3-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e908\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-3-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-4-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e1008\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-4-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-250kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345\"\u003e250\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e1106\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-250kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-350kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345\"\u003e350\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e1419\u003c\/td\u003e\n\u003ctd\u003e340\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-350kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-500kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345\"\u003e500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e1737\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-500kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-750kcmil-61-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345\"\u003e750\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2364\u003c\/td\u003e\n\u003ctd\u003e510\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-750kcmil-61-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1000kcmil-61-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-34\"\u003e1000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2925\u003c\/td\u003e\n\u003ctd\u003e595\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/medium-voltage-power-cable\/35kv-electronic-utility-cable\/empowr-1000kcmil-61-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-34\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129960185919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_5bad1f21-7afa-47d0-88be-20b2c50cd1b6.jpg?v=1571726282"},{"product_id":"empowr-350kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 350kcmil 37 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e1419\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129961824319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_608e0a57-21ac-4acf-9dcc-1cd18b136d26.jpg?v=1571726288"},{"product_id":"empowr-4-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 4\/0 AWG 19 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.528\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e1008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129963921471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a47d388c-fcd9-485c-9616-0e56d77d2daf.jpg?v=1571726288"},{"product_id":"empowr-4-0-awg-19-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-urd-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 4\/0 AWG 19 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE URD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.588\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e1318\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (2)(induct)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129964085311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_04f6e213-823f-4c5d-b669-a649ffbb39cf.jpg?v=1571726288"},{"product_id":"empowr-500kcmil-37-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 500kcmil 37 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.891\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e1737\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129965592639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_d6153afd-92d1-47df-89b7-60b2eb26c912.jpg?v=1571726289"},{"product_id":"empowr-750kcmil-61-wires-35-kv-concentric-neutral-underground-distribution-cable-al-cond-type-ud-345-mils-trxlpe-insulation","title":"General Cable EmPowr® 750kcmil 61 Wires 35 kV Concentric Neutral Underground Distribution Cable Al Cond. TYPE UD 345 mils TRXLPE Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Cable:\u003c\/strong\u003eLead-free cross-linked semi-conducting conductor shield, insulation and semiconducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI\/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Tree-Retardant Cross-linked Polyethylene (TRXLPE) insulated concentric neutral cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Solid or Class B compressed concentric lay stranded 1350 aluminum. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting polymeric stress control layer. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Extruded, unfilled, lead-free Tree-Retardant Cross-linked Polyethylene (TRXLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded lead-free semi-conducting thermosetting layer, clean and free stripping from insulation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e Helically applied, annealed, solid bare copper wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e \u003cbr\u003e • Lead-free environmentally friendly cable \u003cbr\u003e • Triple-extruded for clean interfaces\u003cbr\u003e • Dry nitrogen cure for enhanced performance \u003cbr\u003e • Class 10,000 environment utilized for cable core material handling \u003cbr\u003e • Excellent moisture resistance \u003cbr\u003e • High dielectric strength \u003cbr\u003e • Low dielectric loss \u003cbr\u003e • Excellent resistance to water treeing \u003cbr\u003e • Clean-stripping insulation shield \u003cbr\u003e • Sunlight-resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating: \u003c\/strong\u003e\u003cbr\u003e • Normal - 90°C \u003cbr\u003e • Emergency* - 130°C \u003cbr\u003e • Short Circuit - 250°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e EmPowr® Link+ cables are intended for use in dry or wet locations for distribution of single or three phase medium voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1\/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions: \u003c\/strong\u003e\u003cbr\u003e • Copper conductors \u003cbr\u003e • STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 \u003cbr\u003e • BlFlLL® blocked conductor and cable core\/ jacket. Tested in accordance with ICEA T-34-664 \u003cbr\u003e • True Triple Extrusion \u003cbr\u003e • UltraPowr® smoother and cleaner semi-conducting conductor shield \u003cbr\u003e • Low-strip insulation shield \u003cbr\u003e • Flat strap concentric neutral \u003cbr\u003e • Red stripes on jacket \u003cbr\u003e • Semi-conducting thermoplastic jacket \u003cbr\u003e • Overlaying PVC jacket with separator tape \u003cbr\u003e • Deformation-resistant polypropylene jacket \u003cbr\u003e • CDC® Combined Duct \u0026amp; Cable \u003cbr\u003e • 3 X 1\/C triplex or parallel \u003cbr\u003e • Type MV-90 UL 1072 \u003cbr\u003e • TRXLPE Class III insulation for 105°\/140°C temperature rating \u003cbr\u003e • Type MV-105 UL 1072 (PVC jacket only) \u003cbr\u003e • UL Listed \u003cbr\u003e • Alternative neutral configurations \u003cbr\u003e • EmPowr® Link CL™ XLPE jacketed cable — see EmPowr Link CL catalog section \u003cbr\u003e • 100% pellet inspection\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(al awg or kcmil)\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecompressed conductor(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper neutral(no.of wires)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecopper neutral(wire size awg)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in min.)\u003c\/td\u003e\n\u003ctd\u003e1.670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (1)inches(insulation in max.)\u003c\/td\u003e\n\u003ctd\u003e1.770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ediameter (1)inches(encap lldpe jacket)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thkn.inches(1)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(al cond.)\u003c\/td\u003e\n\u003ctd\u003e703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1)lb\/1000 ft(cu neut.wires)\u003c\/td\u003e\n\u003ctd\u003e508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapprox. weight (1) lb\/1000 ft(total)\u003c\/td\u003e\n\u003ctd\u003e2364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(direct buried)\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (3)(induct)\u003c\/td\u003e\n\u003ctd\u003e510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7129968246847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1efa44f8-15c0-47e2-97ad-6e94e26c5ab5.jpg?v=1571726290"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/general-cable-empowr%c2%ae-35-kv-concentric-neutral-underground-distribution-cable-al-cond-345-mils-trxlpe-insulation.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}