{"title":"General Cable Category 5e® Shielded Cable 4 Pair 24 AWG TIA\/EIA 568-C.2 Patch","description":"","products":[{"product_id":"category-5e-24-awg-7-32-shielded-cable-4-pair-24-awg-tia-eia-568-c-2-patch","title":"General Cable Category 5e® 24 AWG 7\/32 Shielded Cable 4 Pair 24 AWG TIA\/EIA 568-C.2 Patch","description":"Category 5e 24 AWG 7\/32 Shielded Cable 4 Pair 24 AWG TIA\/EIA 568-C.2 Patch\u003cmeta name=\"Description\" content=\"Browse our selection of Category 5e 24 AWG 7\/32 Shielded Cable 4 Pair 24 AWG TIA\/EIA 568-C.2 Patch- LO24P0045664-5e. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"5e Shielded Price, 5e Shielded Quote, 5e Shielded Cable, 4 Pair 24 AWG Cable, TIA\/EIA 568-C.2 Cable, Category 5e Cable, 24 AWG 7\/32 Cable, Transit Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: 4 pair, 24 AWG 7\/32 tinned copper: Diameter: .024\" \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Polyolefin: Diameter: .047\" \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePairs\u003c\/strong\u003e: \u003cbr\u003e • Two conductors twisted together (each pair twisted with a different lay length) \u003cbr\u003e • Color code: \u003cbr\u003e P1: White\/Blue, Blue \u003cbr\u003e P3: White\/Green, Green \u003cbr\u003e P2: White\/Orange, Orange \u003cbr\u003e P4: White\/Brown, Brown \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinding\u003c\/strong\u003e: Polyester tape, 25% min. lap. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e: Aluminum\/polyester tape, 100% coverage  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield\u003c\/strong\u003e: Tinned copper braid, 80% coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Polyrad® XT flame-retardant, low-smoke, irradiated Cross-linked Polyolefin (XLPO), .025\" wall, Dark Gray: Diameter: .300\" \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: \u003cbr\u003e • For high-speed data transmission. Tested to 100 MHz \u003cbr\u003e • Category 5e construction is suitable for use in transit applications with flexible stranding, overall shield and a Polyrad® XT jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e: Meets Category 5e electricals \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances\u003c\/strong\u003e: \u003cbr\u003e \u003cstrong\u003eIndustry\u003c\/strong\u003e: TIA\/EIA 568-C.2 Patch \u003cbr\u003e \u003cstrong\u003eFlame Test\u003c\/strong\u003e: \u003cbr\u003e • 49 CFR Part 238 Appendix B for low-voltage wire and cable \u003cbr\u003e • NYCT Type TX Test 11 per ICEA S-95-658-1999 \u003cbr\u003e • Type B per AAR RP-585 Paragraph 5.9.6 \u003cbr\u003e \u003cstrong\u003eOther\u003c\/strong\u003e: \u003cbr\u003e • BSS 7239 \u003cbr\u003e • ASTM E662\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e24 awg7\/32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of pairs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.047\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003elo24p0045664-5e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163045052479,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_fdc3ce07-9bfc-4239-867e-07c6b03526bf.jpg?v=1571728223"},{"product_id":"category-5e-shielded-cable-4-pair-24-awg-tia-eia-568-c-2-patch","title":"General Cable Category 5e® Shielded Cable 4 Pair 24 AWG TIA\/EIA 568-C.2 Patch","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThis is a tinned copper conductor designed for transit applications within marine environments. It is used to transmit data from various systems and other applications. The tin coat on the conductor improves conductivity, enhances the lifespan, and increases strength. The plating also reduces oxidation and corrosion. The tin plating minimizes wear and tear that is witnessed in bare copper wires. It allows the conductor to be resilient to breakage and prevents lost connections in data transmissions. The plating also makes soldering of the conductor easy at time of installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e \u003cbr\u003e • For high-speed data transmission\u003cbr\u003e • This conductor cable is widely used for data transmission in the marine environments. It transmits data picked from various systems such as communication equipment, smoke detectors, CO2 systems, tank level indications, gas detection equipment, and fire detection equipment to the data management centers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e • Polyolefin\u003cbr\u003e • An insulation material designed of polyolefin is used to protect the conductor. The insulation is free of halogen and does not release noxious substances or gases when subjected to fire or flame. This insulation material is resistant to fire, UV light, abrasion, and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacketing \u003c\/strong\u003e\u003cbr\u003e • Irradiated cross-linked polyolefin\u003cbr\u003e • A jacket material made of irradiated cross-linked polyolefin is used to offer more protection to the primary insulator. This jacketing material is flame retardant and allows low smoke release. It is also resistant to other elements like UV light and chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinding and shielding :\u003c\/strong\u003e A binding of polyester tape is applied on the conductor. An inner shield made of aluminum backed polyester tape is used to provide 100 percent coverage. On top of that, there is an outer shield made of tinned copper braids that provide 80 percent coverage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e • Meets Category 5e electrical\u003cbr\u003e • Compliance- TIA\/EIA 568-C.2 Patch\u003cbr\u003e • Meets flame test- 49 CFR Part 238 Appendix B for low-voltage wire and cable\u003cbr\u003e • Flame test -NYCT Type TX Test 11 per ICEA S-95-658-1999 \u003cbr\u003e • Flame test - Type B per AAR RP-585 Paragraph 5.9.6 \u003cbr\u003e • Pairs- Two conductors twisted together (each pair twisted with a different lay length)\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003econd.\u003cbr\u003e size\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e# of\u003cbr\u003e Pairs\u003c\/td\u003e\n\u003ctd\u003enominal cable\u003cbr\u003e diameter\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003egeneral cable\u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003einches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/type-p-cable-rig-marine-cable\/transit-cable\/category-5e-24-awg-7-32-shielded-cable-4-pair-24-awg-tia-eia-568-c-2-patch\"\u003e24 awg\u003cbr\u003e 7\/32\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e0.300\u003c\/td\u003e\n\u003ctd\u003elo24p0045664-5e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/type-p-cable-rig-marine-cable\/transit-cable\/category-5e-24-awg-7-32-shielded-cable-4-pair-24-awg-tia-eia-568-c-2-patch\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cstrong\u003eELECTRICAL CHARACTERISTICS\u003c\/strong\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003efrequency\u003c\/td\u003e\n\u003ctd\u003einsertion loss\u003c\/td\u003e\n\u003ctd\u003enext\u003c\/td\u003e\n\u003ctd\u003eacrf\u003c\/td\u003e\n\u003ctd\u003erl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003e(mhz)\u003c\/td\u003e\n\u003ctd\u003e(db\/100 m)\u003c\/td\u003e\n\u003ctd\u003e(db)\u003c\/td\u003e\n\u003ctd\u003e(db)\u003c\/td\u003e\n\u003ctd\u003e(db)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003emax.\u003c\/td\u003e\n\u003ctd\u003emin.\u003c\/td\u003e\n\u003ctd\u003emin.\u003c\/td\u003e\n\u003ctd\u003emin.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003ctd\u003e65.3\u003c\/td\u003e\n\u003ctd\u003e63.8\u003c\/td\u003e\n\u003ctd\u003e20.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003ctd\u003e56.3\u003c\/td\u003e\n\u003ctd\u003e51.8\u003c\/td\u003e\n\u003ctd\u003e23.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e6.9\u003c\/td\u003e\n\u003ctd\u003e51.8\u003c\/td\u003e\n\u003ctd\u003e45.7\u003c\/td\u003e\n\u003ctd\u003e24.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e7.8\u003c\/td\u003e\n\u003ctd\u003e50.3\u003c\/td\u003e\n\u003ctd\u003e43.8\u003c\/td\u003e\n\u003ctd\u003e25.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e9.9\u003c\/td\u003e\n\u003ctd\u003e47.2\u003c\/td\u003e\n\u003ctd\u003e39.7\u003c\/td\u003e\n\u003ctd\u003e25.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e11.1\u003c\/td\u003e\n\u003ctd\u003e45.8\u003c\/td\u003e\n\u003ctd\u003e37.8\u003c\/td\u003e\n\u003ctd\u003e25.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003e44.3\u003c\/td\u003e\n\u003ctd\u003e35.8\u003c\/td\u003e\n\u003ctd\u003e24.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e31.25\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003ctd\u003e42.9\u003c\/td\u003e\n\u003ctd\u003e33.9\u003c\/td\u003e\n\u003ctd\u003e23.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e62.5\u003c\/td\u003e\n\u003ctd\u003e20.4\u003c\/td\u003e\n\u003ctd\u003e38.4\u003c\/td\u003e\n\u003ctd\u003e27.9\u003c\/td\u003e\n\u003ctd\u003e20.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e26.4\u003c\/td\u003e\n\u003ctd\u003e35.3\u003c\/td\u003e\n\u003ctd\u003e23.8\u003c\/td\u003e\n\u003ctd\u003e19.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cstrong\u003e DC Resistance\u003c\/strong\u003e: 9.38 O \/100 m (28.6 O\/kft) Max. \u003c\/div\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eDCR Unbalanced\u003c\/strong\u003e: 5% Max. \u003c\/div\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eMutual Capacitance\u003c\/strong\u003e: 55.8 pF\/m (17 pF\/ft) Max. \u003c\/div\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eCapacitance Unbalanced\u003c\/strong\u003e: 330 pF\/100 m (1 pF\/ft) Max. \u003c\/div\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eCharacteristic Impedance\u003c\/strong\u003e: 100 O +\/- 15 O (1-100 MHz) \u003c\/div\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eProp Delay (Skew)\u003c\/strong\u003e: 45 ns\/100 m Max. \u003c\/div\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eVelocity of Propagation\u003c\/strong\u003e: 72% Nom. \u003c\/div\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eTemp. \u0026amp; Voltage Rating\u003c\/strong\u003e: -55?C to +75?C \/ 600 V Max.\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163045314623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/01_8ea021ba-e546-4fbf-8381-69ffae83bc8b.jpg?v=1571728223"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/01_4c031a57-d9c9-4dad-97c0-0a7a4ccec554.jpg?v=1525072376","url":"https:\/\/nassauelectricalspot.com\/collections\/general-cable-category-5e%c2%ae-shielded-cable-4-pair-24-awg-tia-eia-568-c-2-patch.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}