{"title":"Daily Deals","description":"","products":[{"product_id":"1-gauge-15kv-epr-pvc-mv-105-shielded","title":"1 Gauge 15kV EPR-PVC MV-105 Shielded","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:  \u003c\/strong\u003eEPR-PVC- 15KV Shielded, Ungrounded Type MV105 Power Cable is for use in airborne, direct entombment, link plate, raceway, and underground pipe establishments as allowed by the National Electrical Code. These links are equipped for working consistently at a conductor temperature not in excess of 105°C for typical operation, 140°C for crisis over-burden conditions, and 250°C for short circuit conditions, and are appraised at 15,000V, 133% protection level (ungrounded framework). For use in Class I, Div II areas. Most extreme sidewall weight is 1000 lbs. This link can be introduced without the requirement for pulling oil.  EPR-PVC- 15KV Shielded, Ungrounded Type MV105 Power Cable is planned for use as a feeder and can be utilized as a part of a wide range of sorts of uses where greatest conveying limit is required. The link can be introduced in channel, pipe or aeronautical applications and must be upheld by an emissary wire. This link can likewise be covered specifically. The link can work in wet or dry areas and has a most extreme conductor temperature of 105°C. This link is considered satisfactory by Underwriters Laboratories details and the Occupational Safety and Health Administration (OSHA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSearch Terms:  \u003c\/strong\u003e1 gauge cable\u003cstrong\u003e, \u003c\/strong\u003e1 Gauge 15KV EPR-PVC MV-105 Shielded\u003c\/p\u003e\n\u003cp\u003eEPR-PVC, Shielded Cable, Underground Cable, Medium Voltage Cable, MV105, MV-105, Power Cable, Feeder Cable, 15kv Wire, 15kv Cable, Heat-resistant cable, heat resistant cable, direct burial cable, aerial cable, overhead cable, underground cable, Easy pull cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColors: \u003c\/strong\u003eOffered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.\u003c\/p\u003e\n\u003cstrong\u003eRegulations:\u003c\/strong\u003e \u003cbr\u003e \u003cstrong\u003eUL 1072- \u003c\/strong\u003eThese requirements cover the shielded and nonshielded medium-voltage power cables that are described in Tables 1.1 (single-conductor) and 1.2 (multiple-conductor).\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCSA C68.10 - \u003c\/strong\u003eA CSA specification for industrial electrical cables.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCSA FT4\u003c\/strong\u003e\u003cspan style=\"font-family: 'helvetica neue';\"\u003e - 70,000 BTU flame test for cables used in trays should burn the cables for 20 minutes and not exceed 1.5 meters after the test is finished.\u003c\/span\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEEE 383 \u003c\/strong\u003e- Standard for qualifying electric cables and splices for nuclear facilities.\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Polyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene propylene rubber (EPR).\u003c\/p\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size: 12pt; font-family: cambria, serif;\"\u003eConductor: \u003c\/span\u003e\u003c\/strong\u003e \u003cspan style=\"font-size: 12pt; font-family: cambria, serif;\"\u003e100% annealed uncoated copper compact stranded \u003cbr\u003e \u003c\/span\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity in Ducts (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160167891007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-epr-medium-voltage-cables_0a9e8470-6a45-4048-9684-d4c5b5a1ec01.jpg?v=1571727574"},{"product_id":"1-gauge-15kv-epr-pvc-mv-90-shielded","title":"1 Gauge 15kV EPR-PVC MV-90 Shielded","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eEPR-PVC 15kV Grounded, Shielded Type MV90 Power Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable employs a Class B stranded copper conductor that bears ethylene propylene (EPR) rubber insulation and a polyvinyl chloride (PVC) external jacket.  The Class B stranded copper conductor is made of annealed uncoated copper.  Annealed copper is often preferred because the process softens the metal making it more flexible and maneuverable.  The assembly includes two separate layers of an extruded semi-conducting copolymer compound that serves as a shield over the conductors and over the insulation.  The extruded semi-conducting insulation shield is shielded with uncoated helically applied copper wires and then covered in 5 mil bare copper tape.  The outer PVC jacket protects the conductors from extreme temperatures, chemicals, and UV rays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MV-90 Power cable is designed to carry medium voltages up to 5,000 Volts.  These cables are intended for use as a feeder and can be used in many different types of applications. The cable can be installed in conduit, duct or aerial applications and must be supported by a messenger wire. This cable can also be buried directly, but only if it is installed in a system with a grounding conductor in close proximity.  The cable can function in wet or dry locations and has a maximum conductor temperature of 90°C.   Per Underwriters Laboratories specifications, this cable is deemed acceptable by the Occupational Safety and Health Administration (OSHA). \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePer specifications set forth by Underwriters Laboratories, this cable meets standard 1072.  This standard sets the requirements for Type MV-90 cables, ensuring their ability to transmit medium voltages (5,000 Volts) and operate at temperatures up to 90°C. \u003c\/li\u003e\n\u003cli\u003eEthylene propylene components of this cable conform to ICEA S-93-639.\u003c\/li\u003e\n\u003cli\u003eUnderwriters Laboratories specifications deem this cable acceptable in adherence to OSHA guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductive components of this cable are made with Class B stranded annealed uncoated copper.  Copper is an extremely powerful conductor and when the annealing process is applied, the conductor becomes more malleable; an admired quality in most applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductor bears an extruded semi-conducting copolymer compound shield.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Class B copper conductor is insulated by ethylene propylene rubber (EPR).  This insulation helps to stabilize the conductive current and add mechanical strength to the overall assembly. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExtruded semi-conducting copolymer compound is applied directly over the ERP insulation. \u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe PVC outer jacket serves as the cable’s first line of defense UV rays and adds mechanical strength the overall assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding (Al\/Stl):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity in Ducts (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160167923775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-epr-pvc-15000v_9d81134b-efff-4018-92c8-cc1b89344c5c.jpg?v=1571727574"},{"product_id":"1-gauge-5-8kv-power-cable-115-mils","title":"1 Gauge 5-8kV Power Cable 115 Mils","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctrstyle\u003e\n\u003cp\u003eThis cable is made of a concentrically stranded compressed Class B copper conductor, which is annealed making the conductor soft and malleable. The use soft annealed copper conductor improves the flexibility of the cable. Copper conductors are shielded with an extruded strand of a thermosetting semi-conductor layer that helps in controlling any form of stress acting on the conductors, as well as keeping the conductors at hold in their positions hence preventing them from collapsing.\u003c\/p\u003e\n\u003cp\u003eThe copper conductors after the shielding layer is applied they are insulated with an EPR, that is shielded with an extruded insulation shield of a polymeric thermosetting semi-conductor which is separated from the insulation. EPR refers to Ethylene Propylene Rubber and it improves the adaptive features of this cable, making it a good electrical conductor. The assembly is wrapped with a shielding metallic tape of annealed copper and jacketed with the Polyvinyl Chloride (PVC). It is then tested to check if it complies with all the necessary international specification standards such as:\u003c\/p\u003e\n\u003cp\u003e1.Underwriters Laboratory (UL) 1072 \u003cbr\u003e2.UL 1685 \u003cbr\u003e3.Flame test IEEE 1202 \u003cbr\u003e4.NEC 250.4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy go for this Cable?\u003c\/strong\u003e \u003cbr\u003eA flexible cable is the type of cable to go for instead of the rigid and stiff counterparts. Imagine installing a cable in the corners of your power lines and you have the chance to choose between deploying rigid cables and flexible ones, which one would you go for? Of course you won’t hesitate on picking cables with good flexibility. This is because flexible cables are easy to bend since they do not require too much of labor effort thus relieving you from unnecessary cost; such cables are also cost effective. On the other hand, rigid and stiff cables are time consuming as they are difficult and tiresome to handle as compared to flexible cables. Soft copper conductors affirms the flexibility of this cable.\u003c\/p\u003e\n\u003cp\u003eShielding of cables may be seen as a simple feature, but as far as electrical safety and performance feature it is a thing to consider. Shielding is either made of braided copper or an aluminum foil. The copper conductor of this cable is shielded with an extruded layer of a thermosetting semi-conductor made of copper. It helps in controlling any kind of stress attacking the cable. Stress could occur when cables falls on the ground or when they get hit from outside. This shielding is also responsible for holding the conductors firmly in their positions, preventing any further contacts that may occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation \u003c\/strong\u003e \u003cbr\u003eInsulation is a very important aspect when it comes to electrical transmission. You need insulated cables because they offer protection to your life and the cable. Handling bare live conductors carrying electric current is dangerous and should be avoided at all cost. Well, it sounds simple but the truth is you will get electrocuted whenever you get into contact with bare power conductors. Ethylene Propylene Rubber (EPR) of this cables covers your life away from electric shocks. This cable is designed for outdoor applications where it is subjected to operate under harsh environmental conditions such as strong sunlight radiation, moisture, abrasion and corrosive chemicals. EPR protects the cable from such conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePolyvinyl Chloride (PVC)\u003c\/strong\u003e jacketing is a tough outer layer that offers a great protection to the cable. PVC is known to be fungal resistant, meaning that it is not biodegradable even when buried directly. It is flame retardant, moisture resistant, and repellant to corrosive chemicals, oils and gas. This cable is jacketed with PVC making it a preferred cable of choice especially for use in harsh environmental conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e \u003cbr\u003eIt is meant for use as a main feeder as well as branch circuiting for industrial, commercial and electric utility applications. This cable can be installed through direct burial, underground duct and conduit open tray systems. You can deploy it in either wet or dry areas as it has a cold bend operating temperature of -40 degrees Celsius up to 250 degrees Celsius for short circuiting in dry conditions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border-style: solid; border-color: #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Conductors in Cable:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Insulation Thickness (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStranding:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Over Insulation (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.590\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Over Insulation Shield (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity 1\/C in Cable Tray (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity 1\/C Conduit in Air (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Ampacity in Ducts (Amps):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160168022079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-5-35kV_c4f87048-8b57-43a3-ac25-02e17a7ea4bd.jpg?v=1571727574"},{"product_id":"1-gauge-5kv-epr-hypalon-mv-90-non-shielded","title":"1 Gauge 5kV EPR Hypalon MV-90 Non Shielded","description":"\n\n    \n        \u003ctitle\u003e1 Gauge 5kV EPR Hypalon MV-90 Non Shielded\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our 1 Gauge 5kV EPR Hypalon MV-90 Non Shielded. These cables are intended for use as a feeder and can be used in many different types of applications.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Medium Voltage Power Cable, 1 Gauge Power Cable, Type MV90- Power Cable, EPR Hypalon Power Cable, Medium Voltage Power Wire, 5kV Non Shielded Power Cable, 1 Gauge Wire.\"\u003e\n    \n\n    \n        \u003ctrstyle\u003e\n            \u003cp\u003eThe only difference between this cable and the one discussed above is mainly on the shielding aspect. EPR-PVC Type MV-90 cable is not shielded\n                whereas 5kV-8kV Type MV-105 cable is heavily shielded. This cable features Class B concentric strands of a bare annealed copper conductor\n                that is insulated with an Ethylene Propylene Rubber (EPR) and coated with and outer jacketing layer of Polyvinyl Chloride (PVC). The use\n                of annealed copper conductor affirms the flexibility of this cable. Annealing process ensures that the copper becomes more soft and flexible\n                without interfering with its good electrical conductivity properties.\n                \u003cbr\u003e \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eThis cable is approved to meet the following standards:\u003c\/strong\u003e \u003c\/p\u003e\n            \u003cp\u003e1.Tests of approvals to serve as a Type MV-90 in accordance to MV-90 acronym, which authorities the cable to perform under\n                \u003cbr\u003e temperatures not exceeding 90degrees Celsius while transmitting medium power voltage up to 5000 volts. \u003c\/p\u003e\n            \u003cp\u003e2.EPR is approved to comply with ICEA S-68-516 test and NEMA no. WC8 \u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eWhy go for this Cable?\u003c\/strong\u003e\n                \u003cbr\u003eAnnealed copper conductor makes the cable flexible enough and gives you easy time during installation as compared to the standard copper\n                conductors which are stiff and rigid. It reduces the termination time because of its malleability as it requires less effort to handle,\n                especially when bending and folding it to fit in your wiring channel. I would recommend that you make this Type MV-90 EPR-PVC cable your\n                cable of choice and consider it in your power lines.\u003c\/p\u003e\n            \u003cp\u003eEPR insulation offers a superb mechanical strength as well as durability to your cable, thus stabilizing the current flow in the conductors\n                of your cable. You need cables insulated by ethylene propylene rubber in your power lines to ensure you of a long serving period. This\n                cable has an EPR insulation that keeps the cable from both chemical and mechanical damages that may arise in the environment, such as abrasion,\n                chloride chemicals, moisture and oils.\u003c\/p\u003e\n            \u003cp\u003eThis cable is jacketed with a polyvinyl chloride (PVC) layer on the outer surface. PVC is a very tough plastic coating that provides protection\n                to the cable and the electrician during and after the installation. During installation cables may be pulled along the ground, creating\n                friction to act on the surface of the cable in contact with the ground leading to wear and tear of the cable. Well, worry no more for this\n                EPR-PVC Type MV-90 cable because it is covered with a strong PVC jacket that protects it from damages such as wear and tear. Electricians\n                do not have to worry about the risks associated with electrocutions as this cable is not left bare but rather insulated and jacketed with\n                EPR and PVC respectively, as a safety measure.\u003c\/p\u003e\n            \u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\n                \u003cbr\u003eIt is primarily designed as a dual serving cable with a capacity to operate in both wet and dry environmental conditions. This cable is\n                widely applied in industrial, commercial and electric utility installed through cable trays, ducts, troughs, direct burial or aerial.\u003c\/p\u003e\n            \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #495682;\"\u003e\n                        \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e \u003c\/td\u003e\n                        \u003ctd\u003e1\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eStranding:\u003c\/strong\u003e \u003c\/td\u003e\n                        \u003ctd\u003e19\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eDiameter Complete Cable (O.D.) (Inches):\u003c\/strong\u003e \u003c\/td\u003e\n                        \u003ctd\u003e.800\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eWeight Per 1000ft Total (Lbs.):\u003c\/strong\u003e \u003c\/td\u003e\n                        \u003ctd\u003e506\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                        \u003ctd\u003e\n\u003cstrong\u003eAllowable Ampacity Dwelling (Amps):\u003c\/strong\u003e \u003c\/td\u003e\n                        \u003ctd\u003e170\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n                \u003c\/table\u003e\n                \u003cp\u003e \u003c\/p\u003e\n        \u003c\/trstyle\u003e\n    \n\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160168087615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-epr-medium-voltage-cables_aea5bdab-e5d2-4769-a09f-79214a10ae01.jpg?v=1571727574"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/daily-deals.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}