{"title":"Belden Cable Foundation Fieldbus Cable","description":"","products":[{"product_id":"belden-123076f-cable-18-awg-1-pair-foundation-fieldbus-databus-isa-sp-50-multi-conductor-stranded-7x26-aluminum-interlocked-armor-cable","title":"Belden 123076F Cable 18 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 Aluminum Interlocked Armor Cable","description":"Belden 123076F Cable 18 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 Aluminum Interlocked Armor Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 123076F Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 Aluminum Interlocked Armor Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 123076F, 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 Aluminum Interlocked Armor Cable 123076F, 123076F, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable, Aluminum Interlocked Armor Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 1 pair 18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage), tinned copper drain wire, binder, aluminum interlocked armor PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Drain Wire Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003cbr\u003e • Nom. Diameter (in.): 0.280\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Bulk Cable Weight: 38 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 60 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 2.500 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CM, CMX-Outdoor, PLTC-ER\u003cbr\u003e • NEC Articles: 725, 727, 800\u003cbr\u003e • CEC\/C(UL) Specification: CMG\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 01\/01\/2004\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: ITC-ER\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100.000\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.19\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 45.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.0\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.200\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86\u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 7.500\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1666 Riser\u003cbr\u003e • C(UL) Flame Test: FT4\u003cbr\u003e • IEEE Flame Test: 1202, IEEE 383 Vertical Tray Flame Test (70,000 BTU)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Suitability - Burial: Yes - UL\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.046\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.292\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e123076F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161693995071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg.jpg?v=1571727860"},{"product_id":"belden-123077f-cable-22-awg-1-pair-foundation-fieldbus-databus-isa-sp-50-multi-conductor-stranded-7x30-aluminum-interlocked-armor-cable","title":"Belden 123077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable","description":"Belden 123077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 123077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable. Click for a free quote. 22 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 123077F, 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable 123077F, 123077F, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, Aluminum Interlocked Armor Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 22 AWG stranded (7x30) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage), tinned copper drain wire, aluminum interlocked armor, PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Drain Wire Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -30°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Bulk Cable Weight: 18 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 27 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 2.200 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CM, ITC, PLTC\u003cbr\u003e • NEC Articles: 725, 727, 800\u003cbr\u003e • CEC\/C(UL) Specification: CM\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 01\/01\/2004\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.20\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 44.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 23.5\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 17.1\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 11.400 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 2.5 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 UL Loading\u003cbr\u003e • CSA Flame Test: FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e123077F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161694126143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_840e73e1-371c-4936-b8ca-79b494a5ba68.jpg?v=1571727860"},{"product_id":"belden-123078f-cable-22-awg-1-pair-foundation-fieldbus-databus-isa-sp-50-multi-conductor-stranded-7x30-aluminum-interlocked-armor-cable","title":"Belden 123078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable","description":"Belden 123078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 123078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable. Click for a free quote. 22 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 123078F, 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable 123078F, 123078F, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, Aluminum Interlocked Armor Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 22 AWG stranded (7x30) tinned copper conductors, Polyolefin insulation, Beldfoil® shield (100% coverage), tinned copper drain wire, aluminum interlocked armor PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Drain Wire Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +75°C\u003cbr\u003e • UL Temperature Rating: 75°C\u003cbr\u003e • Bulk Cable Weight: 40 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 32 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 3.500 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • CEC\/C(UL) Specification: CM\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 01\/01\/2004\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 150\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.30\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 16.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 8.5\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 0.46\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 78\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 17.1\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 3.300 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 2.5 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 UL Loading\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e123078F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161694224447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_b946d371-3932-4544-a0a8-242de173908d.jpg?v=1571727860"},{"product_id":"belden-1327a-18-awg-2-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1327A 18 AWG 2 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1327A 18 AWG 2 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 2 Pair 18 AWG (7x26) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Thickness: 0.053 in (1.3 mm)\u003cbr\u003e• Nom. Diameter: 0.44 in (11 mm)\u003cbr\u003e• Overall Cable Diameter (Nominal): 0.44 in (11 mm)\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e2\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1327A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1327A_techdata_1.pdf?v=1787897264\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161699663935,"sku":"NES1327A","price":4.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled37_2476de9c-5b35-4bd0-a34f-c1670d252eb6.jpg?v=1787906547"},{"product_id":"belden-1328a-18-awg-5-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1328A 18 AWG 5 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1328A 18 AWG 5 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 5 Pair 18 AWG (7x26) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC - Tinned Copper\u003cbr\u003e\u003cbr\u003e• Material: Tinned Copper (TC)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eShield Type: Tape\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eMaterial: Bi-Laminate (Alum+Poly)\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eCoverage: 100%\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eMaterial Trade Name: Beldfoil\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eDrainwire Type: 18 AWG (7x28) TC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Diameter: 0.55 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e5\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Nominal Diameter: \u003c\/strong\u003e0.048 in\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1328A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1328A_techdata_1.pdf?v=1787897988\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161699696703,"sku":"NES1328A","price":9.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled38_0a641192-aa44-4b57-acf9-3481cf70619f.jpg?v=1787906698"},{"product_id":"belden-1329a-cable-18-awg-8-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x26-pvc-jacket-cable","title":"Belden 1329A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable","description":"Belden 1329A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 1329A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 1329A, 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable 1329A, 1329A, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 8 pair, 18 AWG stranded (7x26) tinned copper conductos, polyolefin insulation, individual and overall Beldfoil® shield (100% coverage), tinned copper drain wire, oil-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Max. Recommended Pulling Tension: 481 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 6.700 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, CMX-Outdoor, ITC, PLTC-ER\u003cbr\u003e • CEC\/C(UL) Specification: CMG\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 09\/01\/2006\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.19\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 45.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.0\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86\u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 4.9\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg C: 7.500 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003cbr\u003e • IEEE Flame Test: 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e1329A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161699795007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_4f302964-fe6e-4f91-a826-81420992d176.jpg?v=1571727861"},{"product_id":"belden-133076f-cable-18-awg-1-pair-foundation-fieldbus-databus-isa-sp-50-multi-conductor-stranded-7x26-steel-interlocked-armor-cable","title":"Belden 133076F Cable 18 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 Steel Interlocked Armor Cable","description":"Belden 133076F Cable 18 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 Steel Interlocked Armor Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 133076F Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 Steel Interlocked Armor Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 133076F, 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 Steel Interlocked Armor Cable 133076F, 133076F, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable, Steel Interlocked Armor Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 1 pair 18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage), tinned copper drain wire, binder, steel interlocked armor PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Drain Wire Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003cbr\u003e • Nom. Diameter (in.): 0.280\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Bulk Cable Weight: 38 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 60 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 2.500 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CM, CMX-Outdoor, PLTC-ER\u003cbr\u003e • NEC Articles: 725, 727, 800\u003cbr\u003e • CEC\/C(UL) Specification: CMG\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 01\/01\/2004\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: ITC-ER\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100.000\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.19\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 45.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.0\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.200\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86\u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 7.500\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1666 Riser\u003cbr\u003e • C(UL) Flame Test: FT4\u003cbr\u003e • IEEE Flame Test: 1202, IEEE 383 Vertical Tray Flame Test (70,000 BTU)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Suitability - Burial: Yes - UL\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.046\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.292\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e133076F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161699827775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_396434b8-2c6b-4ddd-87a6-a644541a17b0.jpg?v=1571727862"},{"product_id":"belden-133077f-cable-22-awg-1-pair-foundation-fieldbus-databus-isa-sp-50-multi-conductor-stranded-7x30-steel-interlocked-armor-cable","title":"Belden 133077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable","description":"Belden 133077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Steel Interlocked Armor Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 133077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Steel Interlocked Armor Cable. Click for a free quote. 22 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 133077F, 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Steel Interlocked Armor Cable 133077F, 133077F, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable,Steel Interlocked Armor Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 22 AWG stranded (7x30) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage), tinned copper drain wire, steel interlocked armor, PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Drain Wire Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -30°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Bulk Cable Weight: 18 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 27 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 2.200 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CM, ITC, PLTC\u003cbr\u003e • NEC Articles: 725, 727, 800\u003cbr\u003e • CEC\/C(UL) Specification: CM\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 01\/01\/2004\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.20\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 44.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 23.5\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 17.1\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 11.400 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 2.5 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 UL Loading\u003cbr\u003e • CSA Flame Test: FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e133077F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161699958847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_979a001a-8caf-40fb-848e-06482738992b.jpg?v=1571727862"},{"product_id":"belden-133078f-cable-22-awg-1-pair-foundation-fieldbus-databus-isa-sp-50-multi-conductor-stranded-7x30-steel-interlocked-armor-cable","title":"Belden 133078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable","description":"Belden 133078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 133078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable. Click for a free quote. 22 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 133078F, 22 AWG 1 Pair Foundation Fieldbus DataBus ISA\/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable 133078F, 133078F, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, Steel Interlocked Armor Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 22 AWG stranded (7x30) tinned copper conductors, Polyolefin insulation, Beldfoil® shield (100% coverage), tinned copper drain wire, aluminum interlocked armor PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Drain Wire Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +75°C\u003cbr\u003e • UL Temperature Rating: 75°C\u003cbr\u003e • Bulk Cable Weight: 40 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 32 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 3.500 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • CEC\/C(UL) Specification: CM\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 01\/01\/2004\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 150\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.30\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 16.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 8.5\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 0.46\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 78\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 17.1\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 3.300 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 2.5 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 UL Loading\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e133078F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161699991615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_a272568e-7bf8-4c1f-8556-1f383f3a4a7c.jpg?v=1571727862"},{"product_id":"belden-1330a-18-awg-12-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1330A 18 AWG 12 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1330A 18 AWG 12 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 12 Pair 18 AWG (7x26) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e• Material: Tinned Copper (TC)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Diameter: 0.81 in \u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1330A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1330A_techdata_1.pdf?v=1787902018\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161700188223,"sku":"NES1330A","price":20.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled39_c87f3c07-966b-4a20-85ac-33a3a45fde49.jpg?v=1787906863"},{"product_id":"belden-1331a-18-awg-16-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1331A 18 AWG 16 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1331A 18 AWG 16 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 16 Pair 18 AWG (7x26) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e• Material: Tinned Copper (TC)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Diameter: 0.92 in \u003cbr\u003e• Overall Cable Diameter (Nominal): 0.92 in \u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1331A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1331A_techdata_1.pdf?v=1787907754\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161700319295,"sku":"NES1331A","price":10.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled40_f2a3476c-e166-40ce-b3af-dd5c9fb4456e.jpg?v=1787909354"},{"product_id":"belden-1332a-cable-18-awg-20-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x26-pvc-jacket-cable","title":"Belden 1332A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable","description":"Belden 1332A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 1332A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 1332A, 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable 1332A, 1332A, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 20 pair, 18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, individual and overall Beldfoil® shield (100% coverage), tinned copper drain wire, oil-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Max. Recommended Pulling Tension: 1148 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 10.200 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, CMX-Outdoor, ITC, PLTC-ER\u003cbr\u003e • CEC\/C(UL) Specification: CMG\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 09\/01\/2006\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.19\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 45.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.0\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86\u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 4.9\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg C: 7.500 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003cbr\u003e • IEEE Flame Test: 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e1332A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161700450367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_1e45ca67-74e5-4a8b-ae97-ad74a248d9fd.jpg?v=1571727862"},{"product_id":"belden-1333a-18-awg-24-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1333A 18 AWG 24 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1333A 18 AWG 24 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 24 Pair 18 AWG (7x26) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e• Material: Tinned Copper (TC)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Diameter: 1.13 in\u003cbr\u003e• Overall Cable Diameter (Nominal): 1.13 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e24\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1333A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1333A_techdata_1.pdf?v=1787908503\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161702318143,"sku":"NES1333A","price":14.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled41_eedf8d8e-fbd7-4af9-a090-e047738f98e7.jpg?v=1787909872"},{"product_id":"belden-1334a-18-awg-1-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1334A 18 AWG 1 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1334A 18 AWG 1 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 1 Pair 18 AWG (7x26) Tinned Copper, PO Insulation, Overall Beldfoil+Tinned Copper Braid (65%) Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)  \u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e• Shield Type: Braid\u003cbr\u003e• Material: Tinned Copper (TC)\u003cbr\u003e• Coverage: 65%\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Jacket:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Thickness: 0.065 in (1.7 mm)\u003cbr\u003e• Nom. Diameter: 0.287 in (7.29 mm)\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cstrong\u003e• \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eOperating Temperature: -40°C to +105°C\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohms\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eharsh environment, digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations, long-distance applications, etc.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eSpecifications:\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSize (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• No. of Pair\u003c\/span\u003e:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• \u003c\/span\u003eStranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• Conductor \u003c\/span\u003eMaterial: \u003c\/strong\u003eTC - Tinned Copper\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• \u003c\/span\u003ePart Number:\u003c\/strong\u003e 1334A\u003c\/p\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1334A_techdata_1.pdf?v=1771396799\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161703661631,"sku":"NES1334A","price":3.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled22_4b86837a-9b3b-453a-b193-f549979a553f.png?v=1771402183"},{"product_id":"belden-1336a-14-awg-1-pair-7x22-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1336A 14 AWG 1 Pair 7x22 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1336A 14 AWG 1 Pair 7x22 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 2 Conductor 14 AWG (7x22H) Tinned Copper, PO Insulation, Overall Beldfoil+Tinned Copper Braid (65%) Shield, Orange PVC Outer Jacket, PLTC.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e• Layer: 1\u003cbr\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)  \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC - Tinned Copper\u003cbr\u003e\u003cbr\u003e• Layer: 2\u003cbr\u003e• Shield Type: Braid\u003cbr\u003e• Material: Tinned Copper (TC)\u003cbr\u003e• Coverage: 65%\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Jacket:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nominal Diameter: 0.43 in\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003cbr\u003eStandards:\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cstrong\u003e• \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eOperating Temperature: -30°C to +90°C\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohms\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eharsh environment, digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eSpecifications:\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSize (AWG): \u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• No. of Pair\u003c\/span\u003e:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• \u003c\/span\u003eStranding: \u003c\/strong\u003e7x22\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• Conductor \u003c\/span\u003eMaterial: \u003c\/strong\u003eTC - Tinned Copper\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• \u003c\/span\u003ePart Number:\u003c\/strong\u003e 1336A\u003c\/p\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1336A_techdata_1.pdf?v=1771399456\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161703759935,"sku":"NES1336A","price":6.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled24_5ba09b87-0ee2-4f41-9b31-37e86c252bf3.png?v=1771402881"},{"product_id":"belden-1337a-18-awg-1-pair-7x26-stranding-tinned-copper-600v-fieldbus-cable","title":"Belden 1337A 18 AWG 1 Pair 7x26 Stranding Tinned Copper 600V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1337A 18 AWG 1 Pair 7x26 Stranding Tinned Copper 600V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 1 Pair 18 AWG (7x26) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, 1 Conductor 18 AWG (7x26) Tinned Copper, PVC Insulation, Orange PVC Outer Jacket, 600V TC-ER.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003eElement: Conductor(s)\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eElement: Ground\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Element: Data Pair(s)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e• \u003c\/strong\u003eMaterial: Bi-Laminate (Alum+Poly)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Thickness: 0.060 in (1.5 mm)\u003cbr\u003e• Nom. Diameter: 0.362 in (9.19 mm)\u003cbr\u003e• Overall Cable Diameter (Nominal): 0.362 in (9.19 mm)\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 600 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -30°C to +75°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e1\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1337A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1337A_techdata_1.pdf?v=1787909182\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161703792703,"sku":"NES1337A","price":6.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled42_6c027abc-149b-4a1f-a5da-895e7c347d24.jpg?v=1787910065"},{"product_id":"belden-1338a-cable-18-awg-2-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x26-pvc-jacket-600v-cable","title":"Belden 1338A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable","description":"Belden 1338A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 1338A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 1338A, 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable 1338A, 1338A, Stranded Tinned Copper Conductor Cable, Flame Retardant Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 18 AWG stranded (7x26) tinned copper conductors, ground wire, polyolefin insulation, inner and overall Beldfoil® shield (100% coverage), tinned copper drain wire, oil and sunlight resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround Wire\u003c\/strong\u003e:\u003cbr\u003e • Ground Wire (Y\/N): Y\u003cbr\u003e • Ground Wire AWG: 18\u003cbr\u003e • Ground Wire Stranding: 7x26\u003cbr\u003e • Ground Wire Conductor Material: TC - Tinned Copper\u003cbr\u003e • Ground Wire Insulation Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: FRPO - Flame Retardant Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -30°C To +75°C\u003cbr\u003e • UL Temperature Rating: 75°C\u003cbr\u003e • Max. Recommended Pulling Tension: 112 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 5.100 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: TC-ER\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 11\/01\/2007\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100.000\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Cond. to Other Conductor \u0026amp; Shield (pF\/ft): 45.000\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.200\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.860\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 600 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 UL Loading\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum Foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e1338A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161703825471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_851ac327-db27-493f-ae64-345133203761.jpg?v=1571727862"},{"product_id":"belden-1339a-cable-18-awg-5-pairs-foundation-fieldbus-or-profibus-pa-databus-isa-sp-50-multi-conductor-stranded-7x26-pvc-jacket-600v-cable","title":"Belden 1339A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus PA DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable","description":"Belden 1339A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus PA DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 1339A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus PA DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 1339A, 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable 1339A, 1339A, Stranded Tinned Copper Conductor Cable, Flame Retardant Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 18 AWG stranded (7x26) tinned copper conductors, ground wire, polyolefin insulation, inner and overall Beldfoil® shield (100% coverage), tinned copper drain wire, oil and sunlight resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround Wire\u003c\/strong\u003e:\u003cbr\u003e • Ground Wire (Y\/N): Y\u003cbr\u003e • Ground Wire AWG: 18\u003cbr\u003e • Ground Wire Stranding: 7x26\u003cbr\u003e • Ground Wire Conductor Material: TC - Tinned Copper\u003cbr\u003e • Ground Wire Insulation Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: FRPO - Flame Retardant Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -30°C To +75°C\u003cbr\u003e • UL Temperature Rating: 75°C Wet\/Dry\u003cbr\u003e • Max. Recommended Pulling Tension: 246 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 6.800 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: TC-ER\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 11\/01\/2007\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100.000\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Cond. to Other Conductor \u0026amp; Shield (pF\/ft): 45.000\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.200\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 600 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 UL Loading\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum Foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e1339A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161703923775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_dc76bb57-48c7-46e6-8cc5-792b45937a04.jpg?v=1571727862"},{"product_id":"belden-1340a-cable-18-awg-8-pairs-foundation-fieldbus-or-profibus-pa-databus-multi-conductor-stranded-7x26-pvc-jacket-600v-cable","title":"Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable","description":"Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 1340A, 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable 1340A, 1340A, Stranded Tinned Copper Conductor Cable, Flame Retardant Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 18 AWG stranded (7x26) tinned copper conductors, ground wire, flame retardant polyolefin insulation, polyolefin fillers, inner and overall Beldfoil® shield (100% coverage), tinned copper drain wire, polypropylene separator, oil and sunlight resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround Wire\u003c\/strong\u003e:\u003cbr\u003e • Ground Wire (Y\/N): Y\u003cbr\u003e • Ground Wire AWG: 18\u003cbr\u003e • Ground Wire Stranding: 7x26\u003cbr\u003e • Ground Wire Conductor Material: TC - Tinned Copper\u003cbr\u003e • Ground Wire Insulation Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: FRPO - Flame Retardant Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -30°C To +75°C\u003cbr\u003e • UL Temperature Rating: 75°C\u003cbr\u003e • Max. Recommended Pulling Tension: 381 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 8.100 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: TC-ER\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 11\/01\/2007\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100.000\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Cond. to Other Conductor \u0026amp; Shield (pF\/ft): 45.000\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.200\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.860\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 600 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 UL Loading\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum Foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e1340A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161703956543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_4335f2ee-7cc2-42d8-9f7e-f69d0c25fd2a.jpg?v=1571727862"},{"product_id":"belden-1359a-cable-18-awg-50-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x26-pvc-jacket-cable","title":"Belden 1359A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable","description":"Belden 1359A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 1359A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 1359A, 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable 1359A, 1359A, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 50 pair, 18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, individual and overall Beldfoil® shields (100% coverage), tinned copper drain wire, oil-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Bulk Cable Weight: 1200 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 2892 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 15.500 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, CMX-Outdoor, ITC, PLTC-ER\u003cbr\u003e • CEC\/C(UL) Specification: PLTC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 02\/19\/2010\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.19\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 45.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.0\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86\u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 4.9\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 Vertical Tray Flame Test\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e1359A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161704972351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_c62a7d35-8230-45f9-81ac-98fefbced968.jpg?v=1571727862"},{"product_id":"belden-1360a-16-awg-1-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1360A 16 AWG 1 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1360A 16 AWG 1 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 1 Pair 16 AWG (7x24H) Tinned Copper, PP Insulation, Overall Beldfoil Shield, Orange PVC Outer Jacket, PLTC-ER, ITC-ER, c(UL) CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e• Nom. Thickness: 0.029 in (0.74 mm)\u003cbr\u003e• Nom. Insulation Diameter: 0.117 in (2.97 mm)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Thickness: 0.065 in (1.7 mm)\u003cbr\u003e• Nom. Diameter: 0.40 in (10 mm)\u003cbr\u003e• Overall Cable Diameter (Nominal): 0.40 in (10 mm)\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V (CMG, PLTC-ER), 150 V (ITC-ER)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e1\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1360A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1360A_techdata_1.pdf?v=1787986094\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161705005119,"sku":"NES1360A","price":2.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled46_139a96f3-9998-40d4-9bc5-536b8802e60c.jpg?v=1788324299"},{"product_id":"belden-1361a-16-awg-2-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1361A 16 AWG 2 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1361A 16 AWG 2 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 2 Pair 16 AWG (7x24H) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e• Nominal Wall Thickness: 0.029 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 16 AWG (7x24) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Thickness: 0.577 in\u003cbr\u003e• Nominal Wall Thickness: 0.055 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e2\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Nominal Diameter: \u003c\/strong\u003e0.059 in\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1361A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1361A_techdata_1.pdf?v=1787987847\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161705103423,"sku":"NES1361A","price":7.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled47_b5dd16e6-3bb8-437b-8151-af478187a8c9.jpg?v=1788324457"},{"product_id":"belden-1362a-16-awg-5-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1362A 16 AWG 5 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1362A 16 AWG 5 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 5 Pair 16 AWG (7x24H) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene \u003cbr\u003e• Nom. Thickness: 0.029 in (0.74 mm) \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride \u003cbr\u003e• Nom. Thickness: 0.065 in (1.7 mm)\u003cbr\u003e• Nom. Diameter: 0.753 in\u003cbr\u003e• Overall Cable Diameter (Nominal): 0.753 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e5\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1362A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1362A_techdata_1.pdf?v=1787988897\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161705136191,"sku":"NES1362A","price":14.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled48.jpg?v=1788324604"},{"product_id":"belden-1363a-16-awg-8-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1363A 16 AWG 8 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1363A 16 AWG 8 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 8 Pair 16 AWG (7x24H) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e• Nominal Wall Thickness: 0.029 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 16 AWG TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Diameter: 0.914 in\u003cbr\u003e• Nominal Wall Thickness: 0.075 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e8\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1363A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1363A_techdata_1.pdf?v=1787993482\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161705168959,"sku":"NES1363A","price":20.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled49.jpg?v=1788324756"},{"product_id":"belden-1364a-16-awg-12-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1364A 16 AWG 12 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1364A 16 AWG 12 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 12 Pair 16 AWG (7x24H) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e• Nom. Thickness: 0.029 in (0.74 mm)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Thickness: 0.075 in (1.9 mm)\u003cbr\u003e• Nom. Diameter: 1.105 in\u003cbr\u003e• Overall Cable Diameter (Nominal): 1.105 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1364A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1364A_techdata_1.pdf?v=1787994140\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161705267263,"sku":"NES1364A","price":30.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled50.jpg?v=1788324904"},{"product_id":"belden-1365a-16-awg-16-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 1365A 16 AWG 16 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 1365A 16 AWG 16 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 16 Pair 16 AWG (7x24H) Tinned Copper, PO Insulation, Individual and Overall Beldfoil Shield, Orange PVC Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: PP - Polypropylene\u003cbr\u003e• Nom. Thickness: 0.029 in (0.74 mm)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: PVC - Polyvinyl Chloride\u003cbr\u003e• Nom. Thickness: 0.075 in (1.9 mm)\u003cbr\u003e• Nom. Diameter: 1.233 in\u003cbr\u003e• Overall Cable Diameter (Nominal): 1.233 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to +105°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 1365A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1365A_techdata_1.pdf?v=1787994634\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161705300031,"sku":"NES1365A","price":13.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled51.jpg?v=1788325082"},{"product_id":"belden-1366a-cable-16-awg-20-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x24-pvc-jacket-cable","title":"Belden 1366A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable","description":"Belden 1366A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 1366A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable. Click for a free quote. 16 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 1366A, 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable 1366A, 1366A, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 20 pair, 16 AWG stranded (7x24) tinned copper conductors, polyolefin insulation, individual and overall Beldfoil® shield (100% coverage), tinned copper drain wire, oil-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 16\u003cbr\u003e • Stranding: 7x24\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Bulk Cable Weight: 810 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 1428 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 13.900 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, CMX-Outdoor, ITC, PLTC-ER\u003cbr\u003e • CEC\/C(UL) Specification: CMG\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 09\/01\/2006\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.19\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 45.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.0\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 4.200\u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 4.9\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003cbr\u003e • IEEE Flame Test: 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.059\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e1364A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161705332799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_2b78e658-8657-4b82-bb93-ca987cc8f45d.jpg?v=1571727863"},{"product_id":"belden-1367a-cable-16-awg-24-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x24-pvc-jacket-cable","title":"Belden 1367A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable","description":"Belden 1367A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 1367A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable. Click for a free quote. 16 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 1367A, 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable 1367A, 1367A, Stranded Tinned Copper Conductor Cable, Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 24 pair, 16 AWG stranded (7x24) tinned copper conductors, polyolefin insulation, individual and overall Beldfoil® shields (100% coverage), tinned copper drain wire, oil-resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: PO - Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 16\u003cbr\u003e • Stranding: 7x24\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -40°C To +105°C\u003cbr\u003e • UL Temperature Rating: 105°C\u003cbr\u003e • Bulk Cable Weight: 950 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 1713 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 15.500 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, CMX-Outdoor, ITC, PLTC-ER\u003cbr\u003e • CEC\/C(UL) Specification: CMG\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU RoHS Compliance Date (mm\/dd\/yyyy): 09\/01\/2006\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.19\u003cbr\u003e • Nom. Capacitance Conductor to Shield (pF\/ft): 45.0\u003cbr\u003e • Nom. Mutual Capacitance (pF\/ft): 24.0\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 66\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 4.200\u003cbr\u003e • Nominal Outer Shield DC Resistance @ 20°C (Ohm\/1000 ft): 4.9\u003cbr\u003e • Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm\/1000 ft\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Recommended Current: 5.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003cbr\u003e • IEEE Flame Test: 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.059\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e1367A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161705431103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_9c8c521e-1244-40cf-b5b4-b51431c4c69d.jpg?v=1571727863"},{"product_id":"belden-183076f-18-awg-1-pair-7x26-stranding-tinned-copper-fieldbus-coax-cable","title":"Belden 183076F 18 AWG 1 Pair 7x26 Stranding Tinned Copper Fieldbus Coax Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 183076F 18 AWG 1 Pair 7x26 Stranding Tinned Copper Fieldbus Coax Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 1 Pair 18AWG (7x26) Tinned Copper, PP insulation, Overall Beldfoil Shield, PVC Inner Jacket, Continuously Corrugated Aluminum Armor, PVC Outer Jacket, ISA\/SP-50 Type A, PLTC, ITC, CM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Element: Pair(s)\u003cbr\u003e• Material: PP - Polypropylene\u003cbr\u003e• Thickness: 0.022 in\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e• Nom. Insulation Diameter: 0.088 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:\u003cbr\u003e\u003cbr\u003e• \u003c\/strong\u003eOuter Shield Type: Tape\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eMaterial: Bi-Laminate (Alum+Poly)\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eCoverage: 100%\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eDrainwire Type: 20 AWG (7x28) TC\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eMaterial: PVC - Polyvinyl Chloride\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Diameter: 0.280 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eArmor:\u003cbr\u003e\u003cbr\u003e• \u003c\/strong\u003eArmor Type and Material: CCA - Continuously Corrugated Aluminum Armor\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Jacket:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eMaterial: PVC - Polyvinyl Chloride\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eThickness: 0.055 in\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Diameter: 0.565 in\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eCable Diameter (Nominal): 0.565 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eexposure to rodent, crush, or cut through force, harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature enviornments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cstrong\u003eSpecifications:\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSize (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e• \u003c\/span\u003eNumber of Pair: \u003c\/strong\u003e1\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eStranding: \u003c\/strong\u003e7x26\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003e• Conductor \u003c\/span\u003eMaterial: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003ePart Number: \u003c\/strong\u003e183076F\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/183076F_1.pdf?v=1764072886\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161752682559,"sku":"NES183076F","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled.png24.jpg?v=1764157128"},{"product_id":"belden-2101a-18-awg-2-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2101A 18 AWG 2 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2101A 18 AWG 2 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 2 Pair 1 AWG (7x26) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nominal Wall Thickness: 0.032 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 0.512 in\u003cbr\u003e•  Nominal Wall Thickness: 0.047 in \u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e2\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2101A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2101A_techdata_1.pdf?v=1788150720\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771032639,"sku":"NES2101A","price":7.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled54.jpg?v=1788331610"},{"product_id":"belden-2102a-18-awg-5-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2102A 18 AWG 5 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2102A 18 AWG 5 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 5 Pair 18 AWG (7x26) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nominal Wall Thickness: 0.032 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Thickness: 0.677 in\u003cbr\u003e• Nominal Wall Thickness: 0.063 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e5\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2102A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2102A_techdata_1.pdf?v=1788152037\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771065407,"sku":"NES2102A","price":13.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled51_f864459c-3165-4ffd-9ffa-700ea3a079f0.jpg?v=1788331775"},{"product_id":"belden-2103a-18-awg-8-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2103A 18 AWG 8 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2103A 18 AWG 8 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 8 Pair 18 AWG (7x26) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nominal Wall Thickness: 0.032 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 0.8 in\u003cbr\u003e• Nominal Wall Thickness: 0.063 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e8\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2103A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2103A_techdata_1.pdf?v=1788153891\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771130943,"sku":"NES2103A","price":19.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled54_b8411d10-3d3b-44ea-93e6-65aaa4e0c122.jpg?v=1788331929"},{"product_id":"belden-2104a-18-awg-12-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2104A 18 AWG 12 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2104A 18 AWG 12 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 12 Pair 18 AWG (7x26) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nominal Wall Thickness: 0.032 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 1.015 in\u003cbr\u003e• Nominal Wall Thickness: 0.085 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2104A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2104A_techdata_1.pdf?v=1788154604\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771196479,"sku":"NES2104A","price":31.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled58.jpg?v=1788332114"},{"product_id":"belden-2105a-18-awg-16-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2105A 18 AWG 16 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2105A 18 AWG 16 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 16 Pair 18 AWG (7x26) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nominal Wall Thickness: 0.032 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 1.126 in\u003cbr\u003e• Nominal Wall Thickness: 0.085 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 120 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2105A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2105A_techdata_1.pdf?v=1788161320\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771229247,"sku":"NES2105A","price":40.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled58_18211818-1366-4fff-9b83-7f520a07d2f4.jpg?v=1788332301"},{"product_id":"belden-2106a-cable-18-awg-20-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x26-fr-pvc-jacket-cable","title":"Belden 2106A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable","description":"Belden 2106A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 2106A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 2106A, 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable 2106A, 2106A, Stranded Tinned Copper Conductor Cable, Cross-Linked Polyolefin Insulation Cable, FR-PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 20 pair, 18 AWG stranded (7x26) tinned copper conductors, XLP insulation, individual and overall Beldfoil® shields (100% coverage), tinned copper drain wire, sunlight- and oil-resistant FR-PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: XLP - Cross-Linked Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: FR PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend\u003cbr\u003e • UL Temperature Rating: 90°C Wet\/Dry\u003cbr\u003e • Installation Temperature Rating: 25°C\u003cbr\u003e • Bulk Cable Weight: 734 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 1170 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 12.500 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, ITC, PLTC-ER\u003cbr\u003e • CSA Specification: AWM I A\/B II A\/B, C22.2 #230 Type TC; C22.2#239 Type CIC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: IEC 61158-2 (ISA\/SP-50) Type A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Conductor to Conductor (pF\/ft): 22.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 64.000\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Operating Voltage - Other: 300V RMS (CSA CIC type TC)\u003cbr\u003e • Max. Recommended Current: 5.4 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • CSA Flame Test: FT4\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.249\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e2106A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771327551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_ba6c4e34-2e84-4954-a104-a5a3c5abe8f4.jpg?v=1571727898"},{"product_id":"belden-2107a-cable-18-awg-24-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x26-fr-pvc-jacket-cable","title":"Belden 2107A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable","description":"Belden 2107A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 2107A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 2107A, 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable 2107A, 2107A, Stranded Tinned Copper Conductor Cable, Cross-Linked Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 24 pair, 18 AWG Stranded (7x26) Tinned Copper, 300V, Individually Foil Shielded Pairs, Overall Beldfoil Shield, Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant FR-PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: XLP - Cross-Linked Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: FR PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend\u003cbr\u003e • UL Temperature Rating: 90°C Wet\/Dry\u003cbr\u003e • Installation Temperature Rating: -25°C\u003cbr\u003e • Bulk Cable Weight: 797 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 1400 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 14 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, ITC, PLTC-ER\u003cbr\u003e • CSA Specification: AWM I A\/B II A\/B, C22.2 #230 Type TC; C22.2#239 Type CIC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: IEC 61158-2 (ISA\/SP-50) Type A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Conductor to Conductor (pF\/ft): 22.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 64.000\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Operating Voltage - Other: 300V RMS (CSA CIC type TC)\u003cbr\u003e • Max. Recommended Current: 5.4 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • CSA Flame Test: FT4\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.389\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e2107A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771360319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_27a9d05e-978e-486b-a43b-f0ef6adabadd.jpg?v=1571727898"},{"product_id":"belden-2108a-18-awg-50-pair-7x26-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2108A 18 AWG 50 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2108A 18 AWG 50 Pair 7x26 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 50 Pair 18 AWG (7x26) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset) \u003cbr\u003e• Nominal Wall Thickness: 0.032 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 20 AWG (7x28) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly) \u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 1.947 in \u003cbr\u003e• Nominal Wall Thickness: 0.12 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 120 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e50\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2108A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2108A_techdata_1.pdf?v=1788162146\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771393087,"sku":"NES2108A","price":97.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled58_8bd102fc-aaf9-4077-8890-b753d1d92000.jpg?v=1788332531"},{"product_id":"belden-2109a-16-awg-1-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2109A 16 AWG 1 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2109A 16 AWG 1 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 1 Pair 16 AWG (7x24H) Tinned Copper, XLPO Insulation, Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 0.365 in\u003cbr\u003e•  Nominal Wall Thickness: 0.047 in \u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eVoltage Rating [V]: 300 V RMS\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 120 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -25°C Cold Impact -40°C to +90°C -55°C Cold Bend\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations, long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e1\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2109A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2109A_techdata_1.pdf?v=1788238877\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161771491391,"sku":"NES2109A","price":4.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled58_6712be03-8187-4899-88f4-fd82ed50bff1.jpg?v=1788332777"},{"product_id":"belden-2110a-16-awg-2-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2110A 16 AWG 2 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2110A 16 AWG 2 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 2 Pair 16 AWG (7x24H) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nominal Wall Thickness: 0.038 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 16 AWG (7x24) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter:  0.629 in\u003cbr\u003e• Nominal Wall Thickness: 0.063 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 120 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e2\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2110A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2110A_techdata_1.pdf?v=1788239854\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161775423551,"sku":"NES2110A","price":10.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled37_0b83843e-f4f7-4a61-9b8c-82237d7b8bb2.jpg?v=1788338182"},{"product_id":"belden-2111a-16-awg-5-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2111A 16 AWG 5 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2111A 16 AWG 5 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 5 Pair 16 AWG (7x24H) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nominal Wall Thickness: 0.038 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 16 AWG (7x24) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 0.789 in\u003cbr\u003e• Nominal Wall Thickness: 0.063 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e5\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2111A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2111A_techdata_1.pdf?v=1788258455\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161776406591,"sku":"NES2111A","price":19.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled58_1e825d4b-c336-466e-94f3-7d766c3ea5a6.jpg?v=1788338366"},{"product_id":"belden-2112a-cable-16-awg-8-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x24-fr-pvc-jacket-cable","title":"Belden 2112A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable","description":"Belden 2112A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 2112A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable. Click for a free quote. 16 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 2111A, 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable 2111A, 2111A, Stranded Tinned Copper Conductor Cable, Cross-Linked Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 8 pair, 16 AWG Stranded (7x24) Tinned Copper, 300V, Individually Foil Shielded Pairs, Overall Beldfoil (100% Shield Coverage), Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant FR-PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: XLP - Cross-Linked Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 16\u003cbr\u003e • Stranding: 7x24\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: FR PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend\u003cbr\u003e • UL Temperature Rating: 90°C Wet\/Dry\u003cbr\u003e • Installation Temperature Rating: -25°C\u003cbr\u003e • Bulk Cable Weight: 478 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 786 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 10 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, ITC, PLTC-ER\u003cbr\u003e • CSA Specification: AWM I A\/B II A\/B, C22.2 #230 Type TC; C22.2#239 Type CIC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: IEC 61158-2 (ISA\/SP-50) Type A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Conductor to Conductor (pF\/ft): 22.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 64.000\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 4.200\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Operating Voltage - Other: 300V RMS (CSA CIC type TC)\u003cbr\u003e • Max. Recommended Current: 10.1 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • CSA Flame Test: FT4\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.982\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e2112A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161778339903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_09b7e6a8-f179-4641-ae79-baf14d8ee50d.jpg?v=1571727900"},{"product_id":"belden-2113a-16-awg-12-pair-7x24-stranding-tinned-copper-300v-fieldbus-cable","title":"Belden 2113A 16 AWG 12 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2113A 16 AWG 12 Pair 7x24 Stranding Tinned Copper 300V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 12 Pair 16 AWG (7x24H) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, CMG\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nominal Wall Thickness: 0.038 in\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 18 AWG (7x26) TC  - Tinned Copper\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e• Material Trade Name: Beldfoil\u003cbr\u003e• Drainwire Type: 16 AWG (7x24) TC  - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 1.186 in\u003cbr\u003e• Nominal Wall Thickness: 0.085 in \u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 300 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e16\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x24\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2113A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2113A_techdata_1.pdf?v=1788258958\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161781878847,"sku":"NES2113A","price":42.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled37_d542c3b3-2dfa-4f62-9b5b-3c8b17b3ae2a.jpg?v=1788338548"},{"product_id":"belden-2114a-cable-16-awg-16-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x24-fr-pvc-jacket-cable","title":"Belden 2114A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable","description":"Belden 2114A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 2114A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable. Click for a free quote. 16 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 2114A, 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable 2114A, 2114A, Stranded Tinned Copper Conductor Cable, Cross-Linked Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 16 pair, 16 AWG Stranded (7x24) Tinned Copper, 300V, Individually Foil Shielded Pairs, Overall Beldfoil (100% Shield Coverage), Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant FR-PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: XLP - Cross-Linked Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 16\u003cbr\u003e • Stranding: 7x24\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: FR PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend\u003cbr\u003e • UL Temperature Rating: 90°C Wet\/Dry\u003cbr\u003e • Installation Temperature Rating: -25°C\u003cbr\u003e • Bulk Cable Weight: 847 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 1536 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 13.250 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, ITC, PLTC-ER\u003cbr\u003e • CSA Specification: AWM I A\/B II A\/B, C22.2 #230 Type TC; C22.2#239 Type CIC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: IEC 61158-2 (ISA\/SP-50) Type A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Conductor to Conductor (pF\/ft): 22.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 64.000\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 4.200\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Operating Voltage - Other: 300V RMS (CSA CIC type TC)\u003cbr\u003e • Max. Recommended Current: 7.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • CSA Flame Test: FT4\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e2114A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161791053887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_b13a095f-5779-4f5f-9424-8018c0021678.jpg?v=1571727901"},{"product_id":"belden-2115a-cable-16-awg-20-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x24-fr-pvc-jacket-cable","title":"Belden 2115A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable","description":"Belden Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable 2115A\u003cmeta name=\"Description\" content=\"Browse our selection of Belden Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable 2115A. Click for a free quote. 16 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 2115A, 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable 2115A, 2115A, Stranded Tinned Copper Conductor Cable, Cross-Linked Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 20 pair, 16 AWG Stranded (7x24) Tinned Copper, 300V, Individually Foil Shielded Pairs, Overall Beldfoil (100% Shield Coverage), Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant FR-PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: XLP - Cross-Linked Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 16\u003cbr\u003e • Stranding: 7x24\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: FR PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend\u003cbr\u003e • UL Temperature Rating: 90°C Wet\/Dry\u003cbr\u003e • Installation Temperature Rating: -25°C\u003cbr\u003e • Bulk Cable Weight: 1037 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 1911 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 14.750 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, ITC, PLTC-ER\u003cbr\u003e • CSA Specification: AWM I A\/B II A\/B, C22.2 #230 Type TC; C22.2#239 Type CIC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: IEC 61158-2 (ISA\/SP-50) Type A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Conductor to Conductor (pF\/ft): 22.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 64.000\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 4.200\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Operating Voltage - Other: 300V RMS (CSA CIC type TC)\u003cbr\u003e • Max. Recommended Current: 7.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • CSA Flame Test: FT4\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.469\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e2115A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161798557759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_7f350f07-ec5a-41f6-bf77-2002405742c9.jpg?v=1571727901"},{"product_id":"belden-2116a-cable-16-awg-24-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x24-fr-pvc-jacket-cable","title":"Belden 2116A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable","description":"Belden 2116A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 2116A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable. Click for a free quote. 16 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 2116A, 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable 2116A, 2116A, Stranded Tinned Copper Conductor Cable, Cross-Linked Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 24 pair, 16 AWG Stranded (7x24) Tinned Copper, 300V, Individually Foil Shielded Pairs, Overall Beldfoil (100% Shield Coverage), Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant FR-PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: XLP - Cross-Linked Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 16\u003cbr\u003e • Stranding: 7x24\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: FR PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend\u003cbr\u003e • UL Temperature Rating: 90°C Wet\/Dry\u003cbr\u003e • Installation Temperature Rating: -25°C\u003cbr\u003e • Bulk Cable Weight: 1219 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 2286 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 16.500 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, ITC, PLTC-ER\u003cbr\u003e • CSA Specification: AWM I A\/B II A\/B, C22.2 #230 Type TC; C22.2#239 Type CIC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: IEC 61158-2 (ISA\/SP-50) Type A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Conductor to Conductor (pF\/ft): 22.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 64.000\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 4.200\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Operating Voltage - Other: 300V RMS (CSA CIC type TC)\u003cbr\u003e • Max. Recommended Current: 7.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • CSA Flame Test: FT4\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.638\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e2116A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161799376959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_7883080f-95a6-4229-89dd-56ea9f9fdd23.jpg?v=1571727902"},{"product_id":"belden-2117a-cable-16-awg-36-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x24-fr-pvc-jacket-cable","title":"Belden 2117A Cable 16 AWG 36 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable","description":"Belden 2117A Cable 16 AWG 36 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 2117A Cable 16 AWG 36 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable. Click for a free quote. 16 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 2117A, 16 AWG 36 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable 2117A, 2117A, Stranded Tinned Copper Conductor Cable, Cross-Linked Polyolefin Insulation Cable, PVC Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 36 pair, 16 AWG Stranded (7x24) Tinned Copper, 300V, Individually Foil Shielded Pairs, Overall Beldfoil (100% Shield Coverage), Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant FR-PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: XLP - Cross-Linked Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 16\u003cbr\u003e • Stranding: 7x24\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: FR PVC - Polyvinyl Chloride\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend\u003cbr\u003e • UL Temperature Rating: 90°C Wet\/Dry\u003cbr\u003e • Installation Temperature Rating: -25°C\u003cbr\u003e • Bulk Cable Weight: 1875 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 3412 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 19.750 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: CMG, ITC, PLTC-ER\u003cbr\u003e • CSA Specification: AWM I A\/B II A\/B, C22.2 #230 Type TC; C22.2#239 Type CIC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: IEC 61158-2 (ISA\/SP-50) Type A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Conductor to Conductor (pF\/ft): 22.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.2\u003cbr\u003e • Nominal Velocity of Propagation: VP (%): 64.000\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 4.200\u003cbr\u003e • Max. Operating Voltage - UL: 300 V RMS\u003cbr\u003e • Max. Operating Voltage - Other: 300V RMS (CSA CIC type TC)\u003cbr\u003e • Max. Recommended Current: 7.2 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1685 FT4 Loading\u003cbr\u003e • CSA Flame Test: FT4\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e1.952\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e2117A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161803702335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_2dd97c2c-5629-4d7f-8f37-10c43870babf.jpg?v=1571727902"},{"product_id":"belden-2118a-18-awg-1-pair-7x26-stranding-tinned-copper-600v-fieldbus-cable","title":"Belden 2118A 18 AWG 1 Pair 7x26 Stranding Tinned Copper 600V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2118A 18 AWG 1 Pair 7x26 Stranding Tinned Copper 600V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 1 Pair 18 AWG (7x26) Tinned Copper, XLPO Insulation, Overall Beldfoil Shield, TPE Outer Jacket, 600V TC.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e• Material : Tinned Copper (TC)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 0.319 in (8.10 mm)\u003cbr\u003e• Nom. Thickness: 0.047 in (1.2 mm)\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 600 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -25°C Cold Impact -40°C to +90°C -55°C Cold Bend\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations, long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e1\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2118A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2118A_techdata_1.pdf?v=1788259637\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161810976831,"sku":"NES2118A","price":3.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled58_14e8a7b8-72ef-4a51-a8a7-9325f2a7014c.jpg?v=1788338747"},{"product_id":"belden-2119a-18-awg-2-pair-7x26-stranding-tinned-copper-600v-fieldbus-cable","title":"Belden 2119A 18 AWG 2 Pair 7x26 Stranding Tinned Copper 600V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2119A 18 AWG 2 Pair 7x26 Stranding Tinned Copper 600V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 2 Pair 18 AWG (7x26) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, 600V TC-ER.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nom. Thickness: 0.032 in (0.81 mm) \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Thickness: 0.047 in (1.2 mm)\u003cbr\u003e• Nom. Diameter: 0.512 in\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 600 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e2\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2119A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2119A_techdata_1.pdf?v=1788322115\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7161814745151,"sku":"NES2119A","price":7.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled46_0d63bee9-2880-437f-a2c0-0038167c1dcb.jpg?v=1788338911"},{"product_id":"belden-2120a-18-awg-5-pair-7x26-stranding-tinned-copper-600v-fieldbus-cable","title":"Belden 2120A 18 AWG 5 Pair 7x26 Stranding Tinned Copper 600V Fieldbus Cable","description":"\u003cp\u003e\u003cstrong\u003eBelden 2120A 18 AWG 5 Pair 7x26 Stranding Tinned Copper 600V Fieldbus Cable\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e:-\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFieldbus, 5 Pair 18 AWG (7x26) Tinned Copper, XLPO Insulation, Individual and Overall Beldfoil Shield, TPE Outer Jacket, 600V TC-ER.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Material: XLPE - Cross-Linked Polyethylene (Thermoset)\u003cbr\u003e• Nom. Thickness: 0.038 in (0.97 mm)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInner Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOuter Shield:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e• Shield Type: Tape\u003cbr\u003e• Material: Bi-Laminate (Alum+Poly)\u003cbr\u003e• Coverage: 100%\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eOuter Jacket:-\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Material: TPE - Thermoplastic Elastomer\u003cbr\u003e• Nom. Diameter: 0.677 in \u003cbr\u003e• Nominal Wall Thickness: 0.063 in (1.6 mm) \u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eStandards:-\u003cbr\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eUL\u003cstrong\u003e \u003c\/strong\u003eVoltage Rating: 600 V\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eNom. Characteristic Impedance: 100 Ohm\u003cbr\u003e\u003cstrong\u003e• \u003c\/strong\u003eOperating Temperature Range: -40°C to 90°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• \u003c\/strong\u003eHarsh-environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity\/moisture, dust, and oil, remote locations long-distance applications, etc.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSpecifications:-\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Size (AWG): \u003c\/strong\u003e18\u003cbr\u003e\u003cstrong\u003e• No. of Pairs: \u003c\/strong\u003e5\u003cbr\u003e\u003cstrong\u003e• Stranding: \u003c\/strong\u003e7x26\u003cbr\u003e\u003cstrong\u003e• Conductor Material: \u003c\/strong\u003eTC - Tinned Copper\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e 2120A\u003c\/span\u003e\u003c\/p\u003e\n[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2120A_techdata_1.pdf?v=1788322564\"\u003e [\/pdf]\u003c\/embed\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7162201702463,"sku":"NES2120A","price":14.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/Untitled58_3e4c25f9-bab9-4bd8-b401-c0d25c852cb3.jpg?v=1788339063"},{"product_id":"belden-2121a-cable-18-awg-8-pairs-foundation-fieldbus-or-profibus-databus-isa-sp-50-multi-conductor-stranded-7x26-tpe-jacket-600v-cable","title":"Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable","description":"Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable. Click for a free quote. 18 AWG.\"\u003e\u003cmeta name=\"Keywords\" content=\"Belden Cable Price, Belden Cable Quote, Belden Cable 2121A, 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA\/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable 2121A, 2121A, Stranded Tinned Copper Conductor Cable, XLP Insulation Cable, TPE Jacket Cable, Tinned Copper Drain Wire Cable, Industrial Wire Cable, Data Bus Cable, Foundation Fieldbus Cable, ISA\/SP-50 Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • 8 pair, 18 AWG, Stranded (7x26) Tinned Copper, Individually Foil Shielded Pairs, Overall Beldfoil Shield, Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant TPE jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e • Material: XLP - Cross-Linked Polyolefin\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield\u003c\/strong\u003e:\u003cbr\u003e • Type: Tape\u003cbr\u003e • Inner Shield Material: Aluminum Foil-Polyester Tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 20\u003cbr\u003e • Stranding: 7x28\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e:\u003cbr\u003e • AWG: 18\u003cbr\u003e • Stranding: 7x26\u003cbr\u003e • Conductor Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e:\u003cbr\u003e • Material: TPE - Thermoplastic Elastomer\u003cbr\u003e • Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend\u003cbr\u003e • Bulk Cable Weight: 313 lbs\/1000 ft.\u003cbr\u003e • Max. Recommended Pulling Tension: 481 lbs.\u003cbr\u003e • Min. Bend Radius\/Minor Axis: 8 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e:\u003cbr\u003e • NEC\/(UL) Specification: TC-ER\u003cbr\u003e • CSA Specification: AWM I A\/B II A\/B, C22.2 #230 Type TC; C22.2#239 Type CIC\u003cbr\u003e • EU Directive 2011\/65\/EU (ROHS II): Yes\u003cbr\u003e • EU CE Mark: Yes\u003cbr\u003e • EU Directive 2000\/53\/EC (ELV): Yes\u003cbr\u003e • EU Directive 2002\/95\/EC (RoHS): Yes\u003cbr\u003e • EU Directive 2002\/96\/EC (WEEE): Yes\u003cbr\u003e • EU Directive 2003\/11\/EC (BFR): Yes\u003cbr\u003e • CA Prop 65 (CJ for Wire and Cable): Yes\u003cbr\u003e • MII Order #39 (China RoHS): Yes\u003cbr\u003e • Other Specification: IEC 61158-2 (ISA\/SP-50) Type A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e:\u003cbr\u003e • Unaveraged Impedance (Ohm): 100.000\u003cbr\u003e • Nom. Inductance (μH\/ft): 0.220\u003cbr\u003e • Nom. Capacitance Condutor to Conductor (pF\/ft): 22.000\u003cbr\u003e • Maximum Capacitance Unbalance (pF\/ft): 1.200\u003cbr\u003e • Nominal Velocity of Propagation (VP %): 64.000\u003cbr\u003e • Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 5.86\u003cbr\u003e • Max. Operating Voltage - UL: 600 V RMS\u003cbr\u003e • Max. Operating Voltage - Other: 600V RMS (CSA CIC type TC)\u003cbr\u003e • Max. Recommended Current: 7.6 Amps\/Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e:\u003cbr\u003e • UL Flame Test: UL1581 Vertical Tray\u003cbr\u003e • CSA Flame Test: FT4\u003cbr\u003e • IEC Flame Test: 60332-3-24 (Category C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e:\u003cbr\u003e • Suitability - Indoor: Yes\u003cbr\u003e • Suitability - Outdoor: Yes\u003cbr\u003e • Sunlight Resistance: Yes\u003cbr\u003e • Oil Resistance: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e:\u003cbr\u003e • Plenum(Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# pairs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ediameter (in.)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum Foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable - nominal diameter (in.)\u003c\/td\u003e\n\u003ctd\u003e0.800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number\u003c\/td\u003e\n\u003ctd\u003e2121A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7162203144255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Foundation_20Fieldbus_20Cable-lg_f8376a0d-b78f-48d0-aa1a-7ff7e2dfa672.jpg?v=1571727904"}],"url":"https:\/\/nassauelectricalspot.com\/collections\/belden-cable-foundation-fieldbus-cable.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}