{"title":"600 Volt UL Type MC, XLP XHHW-2 Insulation","description":"","products":[{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation","description":"600 Volt UL Type MC, XLP XHHW-2 Insulation\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation\"\u003e\u003cmeta name=\"Keywords\" content=\"Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,XLP XHHW-2 Insulation Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center; font-size: 0.9em;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNo. of Conductors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNet Weight Lbs.\/Mft\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eCatalog Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eAction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01402\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01402\"\u003eHW306 01402\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01402\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01403\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01403\"\u003eHW306 01403\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01403\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01404\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01404\"\u003eHW306 01404\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01404\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01405\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01405\"\u003eHW306 01405\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01405\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01407\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01407\"\u003eHW306 01407\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01407\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01409\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01409\"\u003eHW306 01409\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01409\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01412\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01412\"\u003eHW306 01412\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01412\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01419\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01419\"\u003eHW306 01419\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01419\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01425\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e685\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01425\"\u003eHW306 01425\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01425\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01437\" style=\"color: #0101ff;\"\u003e14\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e935\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01437\"\u003eHW306 01437\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01437\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01202\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01202\"\u003eHW306 01202\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01202\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01203\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01203\"\u003eHW306 01203\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01203\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01204\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01204\"\u003eHW306 01204\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01204\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01205\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01205\"\u003eHW306 01205\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01205\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01207\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01207\"\u003eHW306 01207\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01207\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01209\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01209\"\u003eHW306 01209\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01209\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01212\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01212\"\u003eHW306 01212\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01212\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01219\" style=\"color: #0101ff;\"\u003e12\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e715\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01219\"\u003eHW306 01219\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01219\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01002\" style=\"color: #0101ff;\"\u003e10\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01002\"\u003eHW306 01002\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01002\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01003\" style=\"color: #0101ff;\"\u003e10\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01003\"\u003eHW306 01003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01003\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01004\" style=\"color: #0101ff;\"\u003e10\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01004\"\u003eHW306 01004\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01004\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01005\" style=\"color: #0101ff;\"\u003e10\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01005\"\u003eHW306 01005\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01005\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01007\" style=\"color: #0101ff;\"\u003e10\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e440\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01007\"\u003eHW306 01007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01007\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01009\" style=\"color: #0101ff;\"\u003e10\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01009\"\u003eHW306 01009\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01009\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01012\" style=\"color: #0101ff;\"\u003e10\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01012\"\u003eHW306 01012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw306-01012\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160504221759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306.jpg?v=1571727704"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01002","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01002","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01002\u003cmeta name=\"Description\" content=\"Buy Our product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01002\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01002 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160504320063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_10cbdde2-3cf5-461a-86dc-49dd30e6c8bc.jpg?v=1571727704"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01003","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01003","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01003\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01003\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01003 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160504352831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_847f32e6-bc8c-408e-bc45-32454f9456ad.jpg?v=1571727704"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01004","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01004","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01004\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01004\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01004 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160505499711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_160414b6-a768-4746-a524-dd708843c87e.jpg?v=1571727704"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01005","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01005","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01005\u003cmeta name=\"Description\" content=\"Buy Our product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01005\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01005 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160507170879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_a5a26710-1593-48c2-a122-ccfd6344884f.jpg?v=1571727704"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01007","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01007","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01007\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01007 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01007\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160507695167,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_add9cd0c-1414-4f55-8031-32f5577245b1.jpg?v=1571727704"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01009","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01009","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01009\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01009\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01009 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\n        \"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160507760703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_0514c423-9901-4f8b-8434-4f532d975197.jpg?v=1571727704"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01012","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01012","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01012\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01012\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01012 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\n        \"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160507859007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_c7a894af-effe-42e3-93ed-8191fe22b7f6.jpg?v=1571727704"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01202","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01202","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01202\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01202\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01202 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160507924543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_0d8f6a0e-2d2b-4b8d-8011-fed53d636657.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01203","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01203","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01203\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01203\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01203 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160507957311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_62afa054-d885-47a7-a8d2-b036bc4b6d66.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01204","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01204","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01204\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01204\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01204 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508055615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_5c7174a1-38c3-4397-9f9d-fc9b91c321f8.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01205","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01205","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01205\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01205\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01205 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508088383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_edcd15d9-7af0-409e-a601-b883b88be952.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01207","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01207","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01207\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01207\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01207 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508121151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_3f192f6f-abeb-49e1-8472-ac4708255923.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01209","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01209","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01209\u003cmeta name=\"Description\" content=\"Buy Our product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01209\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01209 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508252223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_2d9c8220-a58f-4190-b548-e007ad3fd4c1.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01212","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01212","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01212\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01212\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01212 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508284991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_d154ab3b-c67a-4b94-a3c9-b1b075274d3c.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01219","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01219","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01219\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01219\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01219 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508317759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_bcddf092-b7a6-41c2-90ca-490de89a3c1a.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01402","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01402","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01402\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01402\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01402 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508448831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_3bc9bbae-2616-4087-a38f-5baf43262bcc.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01403","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01403","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01403\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01403\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01403 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508481599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_c0c724cb-332b-4980-ac6b-6e946db767fb.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01404","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01404","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01404\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01404\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01404 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508514367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_cf6b0931-1139-456a-b836-873af1f04779.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01405","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01405","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01405\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01405\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01405 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508612671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_0deaefc8-79a0-450a-a324-fb08e10bf947.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01407","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01407","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01407\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01407\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01407 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508678207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_e8ec63ae-e944-4253-98ea-0b9d57f1ecec.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01409","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01409","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01409\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01409 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01409\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508710975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_1ab89a96-9e16-42d0-8bc3-5dfd62d1c541.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01412","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01412","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01412\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01412\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01412 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01412\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508809279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_c804e174-6263-4c26-9653-99509cf84e23.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01419","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01419","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01419\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01419\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01419 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01419\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160508842047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_b7cea66f-d1cd-41a8-818d-788bdf9c7708.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01425","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01425","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01425\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01425\"\u003e\u003cmeta name=\"Keywords\" content=\"XLP XHHW-2 Insulation HW306 01425 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,600 Volt UL Type MC Cable,UL Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW306 01425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Control Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black sunlight-resistant PVC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1, Table E-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed, NEC Type MC, UL Standard 1569\u003c\/li\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160509104191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW306_a0ff2233-27c0-40b1-9091-6fc83437caee.jpg?v=1571727705"},{"product_id":"600-volt-ul-type-mc-xlp-xhhw-2-insulation-hw306-01437","title":"600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01437","description":"","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160509136959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW307.jpg?v=1571727705"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/4_87166d71-9678-4a05-871e-5d7f673c3539.jpg?v=1523862043","url":"https:\/\/nassauelectricalspot.com\/collections\/600-volt-ul-type-mc-xlp-xhhw-2-insulation.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}