{"title":"600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation","description":"","products":[{"product_id":"600-volt-ul-type-mc-hl-90-xlp-xhhw-2-insulation","title":"600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation","description":"600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation\"\u003e\u003cmeta name=\"Keywords\" content=\"Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,Power Cable,600 Volt UL Type MC-HL Cable,90 XLP XHHW-2 Insulation Cable,Composite Cable,CT Cable,CT Use 90 XLP Cable,Corrugated Aluminum Armor Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Power and Control Composite Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC-HL, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL listed, Type MC-HL per UL Standard 2225 for use in Class I, Division I hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with NEC requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black flame-retardant and sunlight-resistant PVC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl Conductors: red, blue, orange and yellow\u003c\/li\u003e\n\u003cli\u003ePower Conductors: ICEA Method 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 1: 424MA series - all nickel-plated brass\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series - all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center; font-size: 0.9em;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003ePower Size AWG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; width: 10px; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eP-Insulation Thickness Mils\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNet Weight\u003cbr\u003e Lbs.\/Mft\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eCatalog Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eAction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-01003\" style=\"color: #0101ff;\"\u003e10\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-01003\"\u003eHW308 01003 \/\u003cbr\u003e HW30801003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-01003\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-01003-1\" style=\"color: #0101ff;\"\u003e8\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e510\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-01003-1\"\u003eHW308 08003 \/\u003cbr\u003e HW30808003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-01003-1\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-06003\" style=\"color: #0101ff;\"\u003e6\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-06003\"\u003eHW308 06003 \/\u003cbr\u003e HW30806003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-06003\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-06004\" style=\"color: #0101ff;\"\u003e4\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e805\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-06004\"\u003eHW308 06004 \/\u003cbr\u003e HW30806004\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/nassauelectricalspot.com\/products\/continuously-welded-armor-c-l-x-mc-hl-cable\/hw308-06004\"\u003eRequest A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160519950399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW308.jpg?v=1571727707"},{"product_id":"600-volt-ul-type-mc-hl-90-xlp-xhhw-2-insulation-hw308-01003","title":"600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 01003","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 01003\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 01003\"\u003e\u003cmeta name=\"Keywords\" content=\"90 XLP XHHW-2 Insulation HW308 01003 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,Power Cable,600 Volt UL Type MC-HL Cable,Composite Cable,CT Cable,CT Use 90 XLP Cable,Corrugated Aluminum Armor Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW308 01003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eP-No. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eP-Insulation Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eC-No. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Insulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424MA03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Power and Control Composite Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC-HL, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL listed, Type MC-HL per UL Standard 2225 for use in Class I, Division I hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with NEC requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black flame-retardant and sunlight-resistant PVC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl Conductors: red, blue, orange and yellow\u003c\/li\u003e\n\u003cli\u003ePower Conductors: ICEA Method 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 1: 424MA series - all nickel-plated brass\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series - all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160520048703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW308_1dad9ff5-ada3-4315-acd2-a3668fff3b32.jpg?v=1571727707"},{"product_id":"600-volt-ul-type-mc-hl-90-xlp-xhhw-2-insulation-hw308-06003","title":"600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 06003","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 06003\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 06003\"\u003e\u003cmeta name=\"Keywords\" content=\"90 XLP XHHW-2 Insulation HW308 06003 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,Power Cable,600 Volt UL Type MC-HL Cable,Composite Cable,CT Cable,CT Use 90 XLP Cable,Corrugated Aluminum Armor Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW308 06003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eP-No. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eP-Insulation Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eC-No. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Insulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424MA04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Power and Control Composite Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC-HL, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL listed, Type MC-HL per UL Standard 2225 for use in Class I, Division I hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with NEC requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black flame-retardant and sunlight-resistant PVC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl Conductors: red, blue, orange and yellow\u003c\/li\u003e\n\u003cli\u003ePower Conductors: ICEA Method 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 1: 424MA series - all nickel-plated brass\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series - all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160520081471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW308_7c94226e-cc66-4782-b491-9a8d8dbb6171.jpg?v=1571727707"},{"product_id":"600-volt-ul-type-mc-hl-90-xlp-xhhw-2-insulation-hw308-06004","title":"600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 06004","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 06004\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 06004\"\u003e\u003cmeta name=\"Keywords\" content=\"90 XLP XHHW-2 Insulation HW308 06004 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,Power Cable,600 Volt UL Type MC-HL Cable,Composite Cable,CT Cable,CT Use 90 XLP Cable,Corrugated Aluminum Armor Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW308 06004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eP-No. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eP-Insulation Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eC-No. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Insulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424MA04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Power and Control Composite Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC-HL, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL listed, Type MC-HL per UL Standard 2225 for use in Class I, Division I hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with NEC requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black flame-retardant and sunlight-resistant PVC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl Conductors: red, blue, orange and yellow\u003c\/li\u003e\n\u003cli\u003ePower Conductors: ICEA Method 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 1: 424MA series - all nickel-plated brass\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series - all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160520114239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW308_650a0a42-1674-4a32-ac4e-c43299217b5a.jpg?v=1571727707"},{"product_id":"600-volt-ul-type-mc-hl-90-xlp-xhhw-2-insulation-hw308-08003","title":"600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 08003","description":"\u003cmeta charset=\"utf-8\"\u003e600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 08003\u003cmeta name=\"Description\" content=\"Buy Our Product 600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 08003\"\u003e\u003cmeta name=\"Keywords\" content=\"90 XLP XHHW-2 Insulation HW308 08003 Cable,Aluminum Armor Cable,Copper Conductor Cable,Continously Welded Armor Cable,Control Cable,Power Cable,600 Volt UL Type MC-HL Cable,Composite Cable,CT Cable,CT Use 90 XLP Cable,Corrugated Aluminum Armor Cable\"\u003e\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW308 08003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eP-No. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eP-Insulation Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Wire Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Size AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eC-No. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Insulation Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div. 2 Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424MA04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpervious Continuously Welded Armor - Power and Control Composite Cable\u003c\/li\u003e\n\u003cli\u003e600 Volt UL Type MC-HL, CT Use, 90°C\u003c\/li\u003e\n\u003cli\u003eXLP XHHW-2 Insulation\u003c\/li\u003e\n\u003cli\u003eAluminum Armor\u003c\/li\u003e\n\u003cli\u003eCopper Conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL listed, Type MC-HL per UL Standard 2225 for use in Class I, Division I hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with NEC requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e Impervious continuously welded and corrugated aluminum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e Black flame-retardant and sunlight-resistant PVC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 1581 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eICEA 70,000 BTU\/hr and 210,000 BTU\/hr flame test\u003c\/li\u003e\n\u003cli\u003eIEEE 383 70,000 BTU\/hr flame test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl Conductors: red, blue, orange and yellow\u003c\/li\u003e\n\u003cli\u003ePower Conductors: ICEA Method 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL listed Type CWCMC to IEEE 45\/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.\u003c\/li\u003e\n\u003cli\u003eMeets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion Proof, Class 1 Division 1: 424MA series - all nickel-plated brass\u003c\/li\u003e\n\u003cli\u003eRain Tight: 416MC series - all nickel-plated brass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7160520212543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/lg-HW308_930ce077-b613-4249-a2d5-280d4f8d9f6e.jpg?v=1571727707"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/6_abdf9dba-3b51-4055-bb1e-278eee71f06a.jpg?v=1523865500","url":"https:\/\/nassauelectricalspot.com\/collections\/600-volt-ul-type-mc-hl-90-xlp-xhhw-2-insulation.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}